Illuminated helically arranged photobioreactor connected to a pump and control unit.
Illuminated laboratory photobioreactor with a helical culture space. Light path, circulation and gas supply are considered as a connected system.Photo: bbi-biotech

What a closed photobioreactor provides

A photobioreactor cultivates organisms that use light under defined engineering conditions. This page focuses on closed systems for microalgae and cyanobacteria. Through oxygenic photosynthesis, these organisms can use light energy, incorporate inorganic carbon and release oxygen. Other phototrophic metabolisms exist; the gas discussion below concerns oxygenic photosynthetic cultures.

A closed reactor limits direct exchange with its surroundings and enables deliberate medium and gas delivery. However, it remains connected to the environment through gas pathways, liquid connections and sampling points. Closed therefore does not mean sterile or axenic. Appropriate design depends on whether the objective is biomass, a particular compound or a defined culture for scientific investigation.

Operating strategy follows metabolism rather than culture colour. Photoautotrophic growth uses inorganic carbon as the carbon source, with light providing energy. In mixotrophic cultivation, suitable organisms can additionally use organic compounds. This changes the carbon balance, oxygen demand in darkness and conditions for potential accompanying organisms. Adding sugar is therefore a different process decision, rather than a simple supplement to illumination.

The target may be dry biomass, a pigment, a lipid fraction, a protein or a defined experimental culture. Conditions that increase the fraction of a compound do not necessarily maximise its total daily production. If product content rises while growth falls substantially, calculate overall product formation. Cell disruption, extraction and target-compound stability also belong in the harvest-timing decision.

A biological profile should consequently specify strain identity, trophic mode, intended purity, growth format, product and known light acclimation. Add the engineering constraints: indoor or outdoor operation, available area, intended run length and acceptable interruptions. Together these define a useful photobioreactor task. A transparent vessel with a powerful lamp does not by itself constitute a defined production process.

Start-up has its own light conditions. A freshly inoculated reactor with little biomass shades differently from the later dense culture. Lighting that supports productive operation at high biomass therefore does not create the same exposure per cell at the beginning. The inoculum's previous illumination also matters. A culture transferred from low light may behave differently from one already acclimated to production conditions. Assess start-up through cell inventory, pigment state and observed activity.

For comparable experiments, record inoculum quantity, transferred medium and seed-culture illumination. Increasing light or transferring outdoors is a process step needing its own observations. A hypothetical geometry comparison would otherwise be confounded if one culture were acclimated while the other had just been transferred. Even identical daily photon inputs can produce different trajectories from these starting states. Engineering assessment of geometry therefore begins with biologically comparable initial conditions.

Light input is not the same as lamp power

Electrical lamp power describes the energy consumed by the light source. What matters to the culture is the photon flux and spectrum reaching the reactor surface and being absorbed within the culture. Photon flux density can be expressed in µmol photons m⁻² s⁻¹. Comparisons must specify measurement location, spectral range and illumination direction.

Cells absorb and scatter light. Shading therefore increases as biomass accumulates: near the illuminated wall, cells may already experience light saturation or, under unfavourable conditions, photoinhibition, while deeper regions remain light-limited. Photoinhibition means impairment of photosynthesis through excessive light exposure.

A more powerful lamp does not automatically resolve this difference. Spectrum, culture depth and biomass concentration must be considered together. A light colour that works for one strain is not a universal recommendation for all algae. Cultures can also adjust their pigment composition to illumination; identical colour and cell concentration do not necessarily imply identical light absorption.

A defensible light specification distinguishes radiant power from photon flow. A photon carries energy E = h × c / λ, with Planck's constant h, the speed of light c and wavelength λ. At equal radiant power, longer-wavelength light therefore provides more photons than shorter-wavelength light. This does not establish universal biological superiority of one colour: absorption, pigment systems and photochemical use are additional properties of the culture.

Describe where the measurement is made. A sensor immediately in front of the lamp measures something different from a sensor at the reactor wall behind a cover. Include both inputs with two-sided illumination, and do not silently ignore shading by supports or reflection. Record distance, orientation, spectral range and the condition of the transparent wall. One point measurement has limited ability to represent an unevenly illuminated surface.

Absorbed photon input cannot automatically be calculated by subtracting two directional sensor readings, because scattering and lateral escape affect the balance. Precise statements need a suitable measurement arrangement or radiative-transfer model. The simplified attenuation expression I(z) = I0 × exp(−κ × z) can provide orientation when κ has been determined as an effective attenuation coefficient under the conditions being considered. Here z is in m and κ in m⁻¹. This is not a universal description of strongly scattering cultures illuminated from several directions.

Light saturation means that additional light produces little further increase in the photosynthetic response being measured. Photoinhibition describes impairment associated with excessive exposure; the terms are different. In diagnosis, distinguish reversible regulation, acclimation and more persistent damage. A decrease in a fluorescence parameter alone replaces neither a biomass balance nor a product balance, but it can provide complementary physiological evidence for a focused investigation.

Worked example: separate photons, electricity and biomass

This hypothetical teaching example considers an entry surface of 1 m² illuminated from one side. A constant 500 µmol photons m⁻² s⁻¹ is measured at that surface for 12 hours; the lamp is off outside that period. Daily incident photon quantity is therefore 500 × 10⁻⁶ mol m⁻² s⁻¹ × 1 m² × 43,200 s = 21.6 mol photons. This is an input at the surface, not yet an absorbed or biologically used quantity.

For an additional energy calculation, assume idealised monochromatic light at 660 nm. The physical constants give approximately 181 kJ per mol photons. The 21.6 mol therefore corresponds to about 3.92 MJ, or 1.09 kWh, of incident radiant energy. A different spectrum would give a different conversion. A mole of photons is a quantity of particles, rather than a fixed energy unit independent of wavelength.

Now assume the complete installed lighting delivers 2.5 µmol photons at the reactor surface per joule of electricity under these conditions. In this example, that selected performance figure includes the driver and optical pathway to the measurement surface. Supplying 500 µmol s⁻¹ then requires 200 J s⁻¹, or 200 W, of electrical power. Over 12 hours this is 2.4 kWh. Incident radiant energy and electrical consumption are distinct quantities: losses between the electricity supply and culture surface remain in the balance.

Assume net dry biomass formation over the day is 12 g. This gives 12/21.6 = 0.556 g biomass per mol of incident photons. If an appropriate optical investigation additionally establishes absorption of 80 per cent of input, absorbed photons total 17.28 mol, giving 0.694 g per mol absorbed. The higher figure results from a different denominator and does not demonstrate improved biological performance. The assumed absorption cannot be inferred simply from a culture's green colour.

For the installation comparison, additionally assume 0.24 kWh for circulation and 0.36 kWh for cooling. Together with lighting, the measured electrical consumers use 3.0 kWh per day, giving 4 g of dry biomass per kWh on this boundary. Medium preparation, gas supply, harvesting, drying and infrastructure remain excluded. The figure therefore cannot be called the product's complete energy balance. The example shows why photon productivity, electrical performance and total system demand need separate, explicitly named measures.

Sunlight, heat load and daily accounting outdoors

Outdoor light cannot be described by a constant lamp setting. Daily photon quantity is the time integral of actual photon flux density at the selected reference surface. A brief high midday reading may accompany a modest total daily input. Clouds, orientation, shading and surface soiling change the trajectory. Use time-resolved measurements and identify data gaps. A horizontal weather station does not automatically describe input at a vertical reactor wall.

Total solar radiant energy also differs from the photon quantity within the spectral range being considered for photosynthesis. A broadband solar-radiation instrument and a quantum sensor for a stated spectral interval answer different questions. Radiation outside that photon interval can contribute to heating without appearing in the photon balance. Electrical circulation demand, meanwhile, is not part of incident sunlight. A clear installation balance first records radiation and purchased electricity separately, then states any efficiency measure with an explicit definition.

A hypothetical comparison shows why this matters. Days A and B receive the same total photon quantity, but on day A it is spread over many hours, whereas day B has a short intense midday peak. Equal biomass formation does not follow. Day B may involve transient light saturation, higher culture temperature or changed gas conditions. The physiological response also depends on previous acclimation. Record the trajectory and culture state rather than only the daily total.

The heat balance has further contributions. Pumping power ultimately becomes largely heat, the culture exchanges heat with air and surroundings, and evaporation and liquid streams may affect the inventory. A controlled temperature displays the outcome of this balance. Required cooling duty and the electricity used to provide it are different quantities. A cooling system may transport several units of heat per unit of electrical work, for example, but the actual ratio depends on the equipment and temperatures; it should not be assigned a universal constant value.

Include darkness in daily accounting. Determine net biomass accumulation over a fully defined interval so that night-time respiration and planned harvests are represented. Reporting only biomass gained during daylight answers a different question from reporting useful daily harvest. With continuous harvesting, include all removed material and changes in the complete culture inventory. A day with stable concentration can be productive when biomass is continuously withdrawn.

Operating plans connect these observations with actual capacity reserves. Medium and gas supply should accommodate an extended unfavourable weather period or an unplanned lighting outage within the intended operating concept. After interruption, the culture is not automatically in its previous physiological state. Restart, harvest decisions and comparison of subsequent days should therefore include exposure history. Assess several representative operating periods for a site or equipment decision, rather than extrapolating a selected peak day across the entire period of use.

Geometry determines light paths and operating demands

In flat panels, the distance between the walls is a major geometric variable. In tubular systems, tube diameter shapes the light path; tube length and circulation also influence the development of gas and nutrient gradients. An illuminated stirred tank offers flexible experimental instrumentation, but the relationship between illuminated area and volume becomes less favourable as its diameter increases.

Engineering comparison of closed photobioreactors
FormatUseful characteristicImportant limitation
Flat panelA defined, shallow culture depthSurface cleaning, construction and area requirements
Tubular systemLarge illuminated area through modular constructionCirculation, pressure loss and gas gradients along the path
Illuminated stirred tankAccessible instrumentation and process controlShading as diameter increases
Film or bag systemFlexible, light-transmitting culture enclosureMechanical stability, shape retention and material ageing

A comparison should include the complete installation: supports, lighting, pumps, cooling, gas conditioning and harvesting all belong to it. The price of the transparent culture enclosure alone describes neither investment nor operating cost.

Engineering geometry includes illuminated area, total wetted surface, optical path and footprint. These areas are different. Both faces of a panel may be illuminated, while occupied ground area additionally includes spacing, maintenance access and utilities. Under sunlight, arrangement also changes when a surface receives direct or diffuse light. An areal productivity figure without a stated area basis is therefore difficult to compare meaningfully.

For tubes, diameter affects both the light path and hydraulics. Increasing tube length adds culture volume but also extends the path to the next gas-exchange region. Parallel branches can preserve that path length, but require reasonably uniform distribution. Different flow resistances can give nominally identical modules different residence times and gas conditions. Design must make these differences measurable or sufficiently bounded.

Internal light sources may shorten the distance to the nearest illuminated surface, but create additional wetted surfaces and construction interfaces. Cleaning, heat release, leak tightness and replacement become part of the concept. The question is not merely how much light can be installed, but how optical performance will be maintained through a complete campaign. Achievable light input becomes useful only when the installation can operate reliably with the intended culture.

Carbon dioxide supply and oxygen removal are separate tasks

Photoautotrophic cultures require inorganic carbon. When supplied through CO₂ sparging, the gas must first transfer into the liquid. The inorganic carbon species present, and those the organism can use, depend on factors including pH and physiology. A specified CO₂ concentration in the inlet gas therefore does not establish adequate carbon supply.

Simplified closed flat-panel photobioreactor with incoming light, decreasing light availability within the culture, CO₂-containing inlet gas and O₂-containing exhaust.
Light and gas supply during illuminated operation of an oxygenic photosynthetic culture. Light distribution is qualitative and not to scale. Scroll sideways on small screens or open to enlarge.

During active oxygenic photosynthesis, oxygen can be generated beyond the concentration in equilibrium with ambient air. It can accumulate particularly along long illuminated flow paths. A degassing section or suitable gas throughput supports removal. However, high oxygen readings should not be classified as harmful independently of strain, illumination and culture concentration.

CO₂ addition also influences pH. Dosing based on pH is possible but must account for buffering and other sources of acid or base. At night, or without illumination, the balance changes: cellular respiration can consume oxygen and release CO₂. The gas strategy must accommodate this state as well.

For carbon, distinguish the gas quantity dosed, CO₂ transferred and carbon incorporated net into biomass or product. Some dosed CO₂ can leave again in the exhaust; some may temporarily remain in the liquid's inorganic carbon inventory. pH, buffering, gas composition and cellular uptake affect this distribution. The balance therefore needs defined time boundaries: short-term CO₂ uptake is not necessarily newly formed biomass already.

A simple hypothetical calculation uses the earlier assumption of 12 g of additional dry biomass per day. With an assumed carbon mass fraction of 0.50, it contains 6 g of new carbon. If that carbon comes exclusively from CO₂, 6 × 44/12 = 22 g of CO₂ corresponds to the carbon incorporated. Actual gas demand may be higher because of losses and inventory changes. This describes carbon retained in the material being considered, not the climate impact of the complete production process.

Make the direction of oxygen transfer explicit. For a simplified well-mixed liquid, dCO/dt = rO,net + kLa × (C* − CO). CO is dissolved oxygen concentration, C* is equilibrium concentration with the gas, and rO,net is net photosynthetic production minus respiration. Above C*, the transfer term is negative: oxygen leaves the liquid. A sensor reporting percentage of air saturation can therefore read above 100 per cent without this alone proving measurement error.

Darkness changes rO,net. When photosynthetic production stops and respiration continues, an oxygen-removal task can become an oxygen-supply task. A gas strategy developed only for sunny daytime conditions is incomplete. Clouds, shading or lamp failure can create transitions faster than a manually planned day–night change. Observation and the intended response should include these states.

Worked example: compare oxygen formation with removal

A hypothetical teaching example considers a uniformly mixed culture containing 40 L of liquid. Assume constant net oxygen formation of 2 mmol L⁻¹ h⁻¹, a volumetric transfer coefficient kLa of 10 h⁻¹ and equilibrium concentration C* of 0.25 mmol L⁻¹ under the stated assumed gas and temperature conditions. Neglect liquid flows, spatial differences and changes in gas composition. Total net oxygen formation is 80 mmol O₂ h⁻¹.

At a stationary dissolved oxygen inventory, 0 = rO,net + kLa × (C* − CO). Rearranging gives CO = C* + rO,net/kLa = 0.25 + 2/10 = 0.45 mmol L⁻¹. Relative to the selected equilibrium value of 0.25 mmol L⁻¹, this is 180 per cent. Required removal is 10 × (0.45 − 0.25) = 2 mmol L⁻¹ h⁻¹, matching net formation.

If kLa falls to 5 h⁻¹ while all other model assumptions remain unchanged, calculated CO becomes 0.65 mmol L⁻¹, or 260 per cent. The example demonstrates the direction of the effect: weaker transfer requires a larger concentration difference to achieve the same removal. It does not establish that a real culture would maintain the same net formation at that state, or that either value is biologically acceptable or harmful. Those questions need assessment for the strain, illumination and medium.

In a long tube, spatial uniformity is precisely the assumption that needs challenging. A sensor downstream of the degasser may report a low concentration while the end of the illuminated section has a higher one. Select measurement positions or representative samples accordingly. An overall gas balance complements the local sensor, but does not replace all spatial information. This combination of balance and measurement location is often more useful for design than a single universal threshold.

Circulation and temperature change the light regime

Mixing distributes nutrients and moves cells between regions receiving different light levels. Individual cells can therefore experience alternating light and darkness even with a continuously illuminated lamp. Whether this is beneficial depends on the duration of the transitions and the biological response. More circulation does not automatically mean more photosynthesis.

Pumps and aeration consume energy and create mechanical exposure. Sunlight and artificial illumination can also warm the culture. In outdoor systems, irradiance and ambient temperature change throughout the day. Cooling, shading and light control must therefore be considered together. A bright summer day can present a greater engineering challenge than moderate sunshine.

Separate three timescales: distribution of a soluble addition across the whole system, circulation through a tube or loop, and the sequence of bright and dark exposures experienced by an individual cell. They may differ substantially. A short macroscopic mixing time does not establish that cells experience a favourable light sequence. Similarly, the long circulation time of a tubular system does not describe every movement between the wall and the core.

A hypothetical geometric example assumes 100 m of illuminated tube and mean axial velocity of 0.50 m s⁻¹. Ideal transit time is 200 s, excluding additional pipework and degassing volume. This helps estimate the time to the next gas-exchange region. It cannot calculate individual light–dark sequences because transverse motion, the velocity profile and the light field are missing. Nominal pump flow describes these exposures only indirectly.

Pulsed illumination creates defined light changes at a fixed position; turbulent circulation creates a distribution of cell trajectories. Results from a pulsed-light experiment therefore cannot simply be transferred to an arbitrary stirred reactor. A fair comparison states average photon quantity, peak intensity, pulse duration, dark period and culture condition. If an experiment uses fewer photons and achieves a higher yield per photon, it does not necessarily produce more biomass per day.

A useful investigation combines a characterised light condition with a bounded change in circulation, observing biomass, product, gas balance and energy demand. If productivity rises only slightly while pumping power increases substantially, include that cost in the decision. Appropriate circulation is a process-specific compromise between supply, exposure and demand, rather than a universal instruction to maximise mixing.

Distinguish controlled, unialgal and axenic cultures

Controlled cultivation has defined or regulated process conditions. A unialgal culture contains one algal species but may contain accompanying bacteria. Axenic means free from other living organisms. These terms describe different properties and should not be used interchangeably.

An axenic culture requires suitable starting cultures, sterilised medium and components, and aseptic transfers. Accompanying bacteria can adhere to algal cells or mucilaginous layers. Cleaning the reactor does not remove them from an already contaminated inoculum. Nor does a uniformly green culture demonstrate their absence.

Whether accompanying organisms are acceptable depends on the application and specification. In mechanistic experiments they may confound metabolic measurements; elsewhere a defined consortium may be intentional. Hygienic operation or operation with a reduced microbial burden must therefore be distinguished explicitly from a claimed axenic culture.

Evidence for axenic conditions requires more than the absence of visible foreign cells. Enrichment on one bacterial medium detects only organisms able to grow under those test conditions. Microscopy also has limits at low accompanying-organism abundance or where organisms adhere closely. A defensible statement describes complementary methods, their detection limits and the extent of sampling. A negative finding is method-specific evidence rather than an unlimited guarantee.

The starting culture matters as much as the reactor. A clean vessel cannot make an existing algal–bacterial community axenic merely by enclosing it. Accompanying organisms may contribute to measured carbon or oxygen turnover. If a defined consortium is intended, describe its composition and function accordingly rather than calling it axenic.

Consider two hypothetically identical-looking green cultures with different oxygen consumption at night. Possible explanations include different algal states, different biomass inventories or different accompanying organisms. Evaluate purity testing alongside a normalised respiration balance. Increased dark respiration alone does not identify a contaminant, but can justify a closer investigation of biological composition and reconsideration of experimental comparability.

Preserve transparency and plan the sterile barrier

Deposits on transparent walls reduce light transmission and alter its local distribution. Biofilms can also affect culture condition. Cleaning must therefore restore both microbiological and optical performance. A transparent component is not compatible with every cleaning agent or sterilisation method simply because of its material category.

Autoclaving, steam sterilisation in place or other suitable methods each require compatible construction. Large tube networks need a different assessment from small laboratory vessels. Heat-sensitive medium components may require separate sterile addition. Filters, seals, sampling and degassing must form part of the same protection concept. Cleaning and aseptic processing explains the underlying principles.

Where possible, assess optical performance against a defined initial state. Consistent wall locations, measurement geometry and moisture conditions help distinguish deposits from changed lamp output. Rising electricity demand for unchanged photons at the culture surface may indicate poorer transmission, but lamp or driver changes also need checking. During cultivation, measurements through the broth are additionally influenced by biomass and pigments.

Cleaning and material ageing are separate causes. A removable deposit calls for suitable cleaning action; a permanently altered surface may need replacement or a different material choice. Include repeated thermal and chemical exposure in selection. Long tube networks also require attention to drainability, access to low-flow regions and actual distribution of the cleaning liquid.

Campaign-end decisions can therefore combine optical and biological criteria. Declining output per unit of supplied light may result from self-shading, wall deposits, nutrient limitation or a changed culture state. Planned comparisons before and after suitable cleaning help determine whether optical performance has been restored for later runs. Do not assess cleaning effectiveness solely through the visual impression that a surface looks clear again.

More volume does not mean proportionally more production

Consider a deliberately simplified geometric example: a panel illuminated from one side with an area of 1 m² and a culture depth of 0.04 m contains 0.04 m³, or 40 L. At the same area and a depth of 0.08 m, it contains 80 L. The example ignores frames, internal components and edge effects.

Volume doubles, while the illuminated entry surface stays the same. The incident light supplied under identical illumination therefore does not double. This does not give an exact productivity prediction, but raises an essential design question: how will light reach the additional volume?

Adding similar modules can preserve light paths, but requires uniform medium and gas distribution. Outdoor installations must also account for mutual shading and access. Volumetric productivity, areal productivity and energy demand are different performance measures; their reference basis must be stated explicitly. Scale-up and scale-down covers further process-transfer questions.

In the panel example, the ratio of one-sided illuminated area to culture volume falls from 1/0.04 = 25 m⁻¹ to 1/0.08 = 12.5 m⁻¹. At unchanged incident photon quantity, input per liquid volume consequently halves. Two independent 40-L modules, each with 1 m² of equivalently illuminated surface, would instead provide 80 L with 2 m² of entry area. They preserve the original geometric ratio, but also require twice the correspondingly supplied light area.

Under sunlight, that last assumption is critical. Two modules do not automatically each receive the same daily input if they shade one another or have different orientations. Outdoor installations need irradiance and temperature records over representative periods. An exceptionally productive day is not an annual average. Direct versus diffuse radiation, solar position and operating interruptions can change the comparison. State both the measurement period and area basis.

Scale-up must not conceal unilluminated volumes either. Degassers, collection vessels and connecting lines increase the total culture inventory and alter residence times. Volumetric productivity based only on illuminated tubes differs from productivity based on all culture liquid. Both can be useful, but require explicit labels. Product and medium balances must include the entire relevant inventory within the system boundary.

Assess culture condition and the complete outcome

Biomass concentration, pigment content, nutrient consumption, pH and gas readings provide different information. Optical measurements can change through pigment adaptation even when dry biomass scarcely increases. A relationship established for clear, dilute cultures is therefore not automatically valid throughout cultivation.

Harvesting also belongs in the concept. Dilute cultures mean more liquid to transport and separate. High concentrations do not necessarily simplify the overall process if shading and supply constrain production. Useful selection decisions combine culture purity, light distribution, achievable operating stability and downstream processing. Open algal wastewater systems are a related application, but are not a standard sterile use of this closed-process concept.

For daily assessment, align biological and engineering measurements to the same period: dry biomass, target-compound content, culture volume, harvest quantities, incident photons and electrical consumers. In a continuous culture, stable concentration can coexist with ongoing production because biomass leaves in the harvest. In batch operation, unchanged dry biomass alongside rising optical density may instead reflect pigment acclimation or another optical change.

A product-focused comparison uses recoverable target-compound mass. If 12 g of dry biomass hypothetically contains 5 per cent target compound, the material initially contains 0.60 g. Assuming 70 per cent recovery during extraction leaves 0.42 g. Higher biomass output benefits this target only if changes in content and recovery do not cancel the gain. These numbers illustrate quantity logic alone.

An informative experiment also records strain and purity status, medium, geometry, light measurement, gas delivery, sample handling and intervention history. This makes it possible to distinguish changed biological performance from a changed reference basis. Such traceability is more useful for system selection than an isolated record figure with an unclear light or area denominator.

Distinguish light shortage, gas limits and culture change

Begin diagnosis by asking what has actually changed. A darker culture may contain more biomass, more pigment per cell or a different optical distribution. A lower oxygen reading may indicate less photosynthesis, more respiration or improved removal. Combining the material balance, measurement location and culture observations turns these possibilities into testable explanations.

Diagnostic comparisons in a photobioreactor
ObservationPlausible possibilitiesUseful next check
Optical density rises with little dry-biomass increasePigment acclimation, scattering or measurement rangeCompare dilution series, pigments and consistent dry-mass analysis
Less net growth at midday despite more lightHeat, carbon limitation, exposure stress or gas conditionsCheck temperature, photons, CO₂ supply and local O₂ together
Low O₂ at the degasser, high O₂ at the tube endAccumulation along the illuminated pathCompare transit time, gas exchange and spatial measurements
More lighting electricity with unchanged outputSaturation, shading, deposits or another nutrient limitationCheck photons at the culture surface and nutrient inventory
Unexpected increase in dark respirationMore biomass, altered cell state or accompanying organismsNormalise by biomass and check purity and substrate balance

A hypothetical case illustrates the approach. After several days, biomass production per mol of incident photons falls although the lighting setting is unchanged. The culture has become denser and one wall has a visible deposit. First check whether actual photons reaching the culture surface remain unchanged. Then examine nutrient inventory, gas conditions and the increasing optical load through the culture. Assigning the entire cause to the visible deposit would be premature.

A subsequent development investigation establishes comparable optical states or deliberately varies geometry and harvest concentration. Its purpose is to separate wall losses from shading by the culture. Include the additional operating demand: more circulation, more frequent cleaning or lower concentration may improve light use while increasing harvesting or energy requirements. A useful decision states that relationship explicitly and limits its conclusion to the conditions investigated.

Frequently asked questions

Is a closed photobioreactor automatically sterile?

No. Closed describes its construction. Sterile starting equipment and aseptic interfaces are also required; axenic cultures additionally require appropriate starting cultures and checks.

Do all algae need the same lighting?

No. Spectrum, intensity and timing must suit the organism and culture state. Electrical lamp power alone is not an adequate comparison.

Why can pH rise in an illuminated algal culture?

Inorganic carbon uptake can shift carbonate equilibria and raise pH. Other metabolic reactions and the buffer system also influence the trajectory.

Terms in this chapter

65 terms explained in the glossary