A flow curve answers a specific engineering question

An impeller, pipeline, sampling valve and rheometer impose different deformation histories. A measurement at one rotational speed may therefore represent one equipment question well and another poorly. Assessing representative sampling requires different information from sizing an agitator drive. Define the task and expected deformation range before selecting a model.

For a Newtonian liquid under fixed conditions, shear stress is proportional to shear rate, with dynamic viscosity as the proportionality constant. Non-Newtonian behaviour includes several distinct departures. Shear thinning means decreasing apparent viscosity with increasing shear rate. Yield stress concerns the onset of sustained motion in the chosen model. Time-dependent structural breakdown and elastic storage are further properties, not synonyms for shear thinning.

Biomass concentration, dissolved polymers, particle shape and distribution may contribute together. Increased torque alone does not uniquely indicate longer hyphae or greater dry mass. The connection with filamentous morphology matters, but remains a relationship to investigate.

NASA's explanation for simple fluids distinguishes shear stress, velocity gradient and viscosity. Its air examples are not transferred to culture broth. The following models are mathematical descriptions whose applicability must be tested.

Power-law and Herschel–Bulkley models

For a time-independent power law, τ = Kγ̇ⁿ. Here τ is shear stress in Pa, γ̇ is shear rate in s⁻¹, and n is the dimensionless flow index. K has units Pa·sⁿ. Values n < 1 represent shear thinning; n = 1 gives constant viscosity K. Apparent viscosity is μapp = τ/γ̇ = Kγ̇ⁿ⁻¹. Because K's unit changes with n, comparing K values alone can be misleading.

A power law may be useful over a limited range, but for n < 1 its apparent viscosity diverges as γ̇ approaches zero. This does not establish a measured yield stress. The model need not remain valid at very high shear rates either. Always state the range actually investigated.

The Herschel–Bulkley model adds τ = τ₀ + Kγ̇ⁿ on the flowing branch. τ₀ is a fitted yield-stress parameter in Pa. Its practical determination depends on method, observation duration and model choice. A positive fitted value does not by itself prove that material remains completely motionless below it for an arbitrarily long period.

An additional parameter needs evidence of added information. If both a power law and a yield-stress model fit the few available points, their extrapolations may differ enormously. For equipment selection, another measurement at relevant low shear rates can then be more useful than apparent precision from a three-parameter fit.

Documenting sampling and measurement

The sample must represent the material of interest. A narrow port may exclude or alter large aggregates during withdrawal. Settling before measurement, different sampling positions and transfer delays can all distinguish the sample from the process. Record sampling time, volume, position, transport, waiting period and temperature together.

Measurement geometry must suit structural dimensions. A gap too small relative to suspended particles can measure a different system from the original suspension. Wall slip can decouple observed motion from the assumed internal deformation. Apparently easy flow may then be an interfacial effect. Suitable comparison measurements using another geometry can test this hypothesis.

Pre-shear and rest periods belong to the method. A sample subjected to strong shear before the sweep may have a different structure from a freshly withdrawn resting sample. This is particularly relevant for reversible structural breakdown or mechanically altered aggregates. Re-measuring the same sample is then not automatically an independent repetition of its initial condition.

A useful report includes raw points, not only fitted parameters. Plot stress against shear rate and apparent viscosity against shear rate; retain upward and downward sweeps separately. Do not silently modify negative or below-resolution readings. Explain any observations excluded from parameter estimation and why.

Comparing two synthetic flow curves

The rheology.csv dataset describes two entirely synthetic states. A has K = 0.8 Pa·s⁰·⁵⁵ and B has K = 1.6 Pa·s⁰·⁵⁵; both use n = 0.55. Nine shear rates from 1 to 500 s⁻¹ are evaluated. These values are not properties of a fungal species, product or industrial medium.

For A, apparent viscosity is 0.28385 Pa·s at 10 s⁻¹ but 0.100714 Pa·s at 100 s⁻¹. Both belong to the same material model. Saying that viscosity nearly fell to one third is meaningful only if the tenfold increase in shear rate is also stated. It does not describe sample degradation over time.

At the same shear rate, B has twice A's stress and apparent viscosity, with the same flow index. This permits a clear comparison without confusing n and K. If n differed between the states, ranking would need to be checked at the relevant shear rates: flow curves can cross.

Synthetic material A, K = 0.8 and n = 0.55
Shear rateApparent viscosityInterpretation
10 s⁻¹0.28385 Pa·sOne point on the flow curve
100 s⁻¹0.100714 Pa·sSame model, higher shear rate
40 s⁻¹0.152112 Pa·sReference point for the later mixing model

Flow-curve CSV · Executable calculation · Data dictionary

A broth does not always have a single viscosity. Two synthetic flow curves. Comparing individual viscosity values without matching shear rates can misclassify the states.
Two synthetic flow curves. Comparing individual viscosity values without matching shear rates can misclassify the states. Scroll sideways on small screens or open to enlarge.

Estimating parameters without overstating validity

Taking logarithms gives ln τ = ln K + n ln γ̇. A straight-line slope estimates n and its intercept estimates ln K. The noise-free teaching data recover their generating parameters exactly apart from rounding. This verifies arithmetic; it does not establish that actual broth follows the same model.

A logarithmic fit weights relative differences differently from fitting on the original stress scale. Small absolute errors at low stress can become influential after transformation. Choose the scale to match measurement-error behaviour. Near the instrument's resolution limit, an attractive straight line can be misleading.

An additional test predicts measurements not used for fitting within the relevant range. Systematic discrepancies at both ends suggest an unsuitable model or inconsistent conditions. Increasing goodness of fit through more parameters does not replace that test. A parameter becomes useful when changing it improves an engineering inference.

Retain covariance or sensitivity between K and n. A larger n may be partially compensated by a smaller K. Considering separate error bars alone can generate unrealistic combinations. For an equipment question, uncertainty in predicted stress at a specified shear rate is often more informative than two isolated parameter uncertainties.

From rheometer to stirred vessel

A common engineering approximation relates effective shear rate to agitation frequency: γ̇eff = ksN. Use N in s⁻¹; ks is a dimensionless factor associated with geometry and definition. This Metzner–Otto-type mapping does not claim uniform shear rate throughout the vessel. It assigns an apparent viscosity to a selected global calculation.

The teaching example assumes ks = 10 and N = 4 s⁻¹ solely for illustration. Hence γ̇eff = 40 s⁻¹ and material A has μapp = 0.152112 Pa·s. With ρ = 1000 kg/m³ and impeller diameter d = 0.12 m, the correspondingly defined Reynolds number Re = ρNd²/μapp is approximately 378.67. This checks the model; it is not a general flow-regime threshold.

For a power law, the same definition becomes Re = ρN²⁻ⁿd²/[Kksⁿ⁻¹], whose dimensions cancel. Other generalised Reynolds numbers may use different factors or conventions. An associated power correlation must therefore use the same definition. Importing a correlation from another geometry without assessment creates false precision.

Actual power measurement can complement this approximation by testing whether global torque agrees with it. It does not replace local-flow measurement or assessment of poorly moving regions, gas distribution and biological exposure.

Separating time dependence from shear thinning

Upward and downward sweeps may form a loop. That observation alone does not quantify universal thixotropy. Time and shear rate change together during a sweep; temperature drift, settling or irreversible fragmentation may also contribute. Interpretation needs suitable holds at fixed shear rate and documented recovery periods.

Thixotropy refers to time-dependent, essentially reversible structural breakdown under deformation with recovery under appropriate resting conditions. Distinguish it from the purely shear-rate-dependent instantaneous change represented by a power law. Permanent biomass fragmentation also creates a different material. That change may matter operationally but is not explained solely by a thixotropic parameter.

Temperature is another competing cause. A long test may warm the sample while analysis attributes the entire change to structure. Keep temperature and mechanical history explicit. Biologically active samples may also change composition during the measurement.

Name the timescale relevant to the decision: behaviour immediately after sampling, during a long hold or after repeated pump passage. The answer may require a state-and-time model or an empirical comparison under matched history. One viscosity value without these conditions is insufficient for a consequential transfer.

What change do the data justify?

Decreasing apparent viscosity at higher shear rate does not mean that more agitation solves every mixing task. Global flow, gas distribution, mechanical exposure and heat must be assessed together. Structurally complex broth may contain a well-moving region beside a poorly exchanged region. An effective mean obscures that spatial question.

For transfer, compare at least flow curve, temperature, biomass state, geometry, working volume and relevant operating conditions. Water tests answer basic mechanical questions but not automatically performance in non-Newtonian broth. A surrogate liquid is useful when the properties relevant to the particular task are deliberately selected and checked.

The teaching data support three concrete exercises: reconstruct n and K; calculate μapp for A and B at the same shear rate; vary the assumed ks factor and inspect Re. The last exercise is model sensitivity, not a measured reactor change.

The outcome should identify a justified next investigation, such as more representative sampling, an additional relevant low shear rate, another measurement geometry or direct torque measurement. Rheology then supports a decision. The boundary remains explicit: these selected numbers determine neither acceptable cell exposure nor safe equipment operation.

Consistency index, units and transfer

In τ = Kγ̇ⁿ, shear rate has units s⁻¹. To obtain stress in Pa, K therefore has units Pa·sⁿ. Its unit itself depends on n. Values of K at different exponents cannot simply be compared as two viscosities. Predicted stress or apparent viscosity at an explicitly stated shear rate provides a common basis.

Teaching states A and B differ only in K, with n fixed at 0.55. Consequently B has exactly twice A’s apparent viscosity at every evaluated shear rate. This follows from model construction, not a universal observed relationship between biomass and consistency. With different exponents, curves can cross and their ranking can depend on the evaluated range.

A hypothetical comparison illustrates this: model C with K = 0.5 Pa·s^0.8 and n = 0.8 and model A with K = 0.8 Pa·s^0.55 rank differently at low and high shear rates. Equating 0.8γ̇^0.55 = 0.5γ̇^0.8 gives γ̇ = 1.6^4 = 6.5536 s⁻¹. Above that intersection, C produces higher stresses despite its lower numerical K.

A pumping question therefore evaluates the pipe-relevant range; an impeller correlation uses its justified effective range. One viscosity borrowed from another shear condition can reverse a comparison. Unnoticed mixing of mPa·s, Pa·s and a consistency index without ordinary viscosity units is particularly problematic.

Store parameters with temperature, concentration, sample history, geometry and measurement interval. A later change can then be assessed against characterised conditions. A small well-documented flow curve can be more useful than extensive records without reproducible preparation.

Wall slip and sample structure as alternative explanations

A rheometer infers material response from torque and motion. If the sample slips at the surface, assumed internal deformation no longer matches imposed motion. The instrument may indicate lower apparent viscosity without the entire sample flowing more readily. Distinguish this from genuine shear thinning.

One diagnostic approach compares suitable gaps or surfaces under otherwise controlled conditions. Strong gap dependence can indicate slip, particle geometry or other heterogeneity; it is not unique proof. Large pellets may additionally be selected or mechanically altered by a narrow gap.

The TA Instruments note on yield-stress analysis explicitly discusses protocol dependence and wall-slip limitations. Its examples concern technical structured fluids. Living broth adds possible growth, sedimentation and sample changes. The note’s material values are therefore not adopted as biological prescriptions.

Fresh aliquots for each condition may be useful when measurement irreversibly changes structure, but variability between aliquots then needs assessment. Reusing one sample better controls its initial identity while risking preshear effects. The choice follows the question; perfect control of both is not always possible.

Useful documentation therefore describes mechanical preparation and delay between sampling and measurement. If culture and rheometer operate at different temperatures, account for equilibration. Comparing endpoints without that history may misclassify a technical change as a biological batch effect.

Using two flow curves to choose the next experiment

Suppose a batch has substantially higher apparent viscosity at 10 s⁻¹ but only a small difference at 100 s⁻¹. At least three explanations remain: a changed flow exponent, time-dependent structure or an artefact at low stress. These observations do not sufficiently support a claim of increased biomass alone.

First check matched temperature, sampling time and handling. Then inspect raw torque, instrument limits and unstable portions. Only after these are plausible should different constitutive models be fitted. Adding yield stress may describe observations better without identifying their physical cause.

A subsequent test could use a defined loading sequence: low shear rate, higher shear rate, then return to the initial condition. Whether and how quickly response recovers is informative. It distinguishes time-dependent properties better than one stationary power law. This is experimental logic, not a universal operating instruction with prescribed biological loading values.

Collect appropriate morphology and biomass measurements in parallel. Changed size distribution with similar dry mass argues against biomass amount as the sole explanation. A changed curve in cell-free supernatant may implicate dissolved or very small constituents. Such comparisons still require suitable separation and sample handling.

Frame the result as decision support: which description suffices for the planned pumping, agitation or sampling task, and which uncertainty could change the decision? Tie further fitting to that application. Otherwise parameter counts grow without corresponding process understanding.

A mean shear rate does not automatically give mean dissipation

In simple shear flow, mechanical power per volume is τγ̇. Shear stress has units of Pa and shear rate has units of s⁻¹, so their product is W/m³. Substituting the power-law relation τ = Kγ̇ⁿ gives Kγ̇ⁿ⁺¹. This expression refers to the stated simple-shear condition. In a general three-dimensional flow, the corresponding quantity is calculated from the stress and rate-of-deformation tensors; an arbitrarily selected velocity divided by a distance does not replace that full description.

An original two-zone case demonstrates the difference between local and averaged calculations. Assume equal-sized zones with identical rheological parameters K = 0.8 Pa sⁿ and n = 0.55, each idealised as simple shear. Their shear rates are 10 s⁻¹ and 100 s⁻¹. Mean power per volume is then the average of 0.8 × 101.55 and 0.8 × 1001.55. The exponent is the decimal value 1.55, arising from n + 1. This explicit notation matters because the calculation uses a nonlinear power of shear rate.

The two local values are 28.385 W/m³ and 1007.140 W/m³, with a mean of 517.763 W/m³. Averaging shear rate first to obtain 55 s⁻¹ and only then evaluating the constitutive expression gives approximately 398.705 W/m³. The supplementary calculation script provides the precise latter value. The discrepancy comes from the nonlinear power: a mean quantity cannot generally substitute for a strongly varying spatial field when that field enters a nonlinear expression.

This calculation neither establishes actual shear rates inside a stirred vessel nor assesses biological damage. It isolates the difference between two mathematical averaging procedures under explicit assumptions. Its practical consequence is a more precise model question: is the intended prediction an average transport quantity, energy transfer, or a distribution of local events? Each question may require different information about spatial flow. The discussion of local exposure and mean power helps keep these quantities distinct when choosing the next level of model detail.

What can go wrong when extrapolating towards rest

For a shear-thinning power law with n below 1, apparent viscosity Kγ̇ⁿ⁻¹ grows without bound as shear rate approaches zero. Yet the corresponding shear stress Kγ̇ⁿ approaches zero when n is positive. An unbounded apparent viscosity at very low shear rate therefore does not demonstrate a yield stress. It is initially a property of the selected mathematical expression. The Herschel-Bulkley model includes a separate yield-stress parameter, whose experimental determination brings additional requirements.

Measurements over an intermediate shear-rate range do not automatically establish behaviour outside that range. A very good fit between two documented measurement limits can still allow several quite different extensions towards small shear rates. This matters when assessing slowly moving regions. A design model must not silently treat extrapolation in those regions as an experimental finding. At very high shear rates, it is likewise necessary to establish whether the sample, instrument and temperature control actually characterised that range.

Numerical flow models often need a bounded evaluation of such constitutive laws. Introducing a lower limit for the shear rate used in the calculation or an upper limit for the resulting viscosity changes the model. Such a limit can prevent numerical difficulties, but it does not constitute a newly measured material property. Its value, units and rationale should be documented. The next question is whether the intended prediction remains stable when the limit is varied over a defensible range.

A targeted comparison can initially use the same measured flow curve throughout its supported range and vary only the low-shear extension. If global power and relevant concentration trajectories remain similar, the prediction may be relatively insensitive to that particular choice. If the size or residence duration of a weakly exchanged region changes substantially, further evidence is needed specifically there. This outcome is not a general certification of model quality; it concerns one prediction under the variants actually examined.

Before the next experiment, identify which uncertainty controls the decision. An additional measurement within an already well described range does not resolve an open question about near-rest behaviour. Conversely, elaborate characterisation at extremely low shear rates offers little benefit if the relevant process question concerns a different range entirely. Measurement range, constitutive law and engineering decision should justify one another. The manufacturer method note on yield-stress analysis explains concrete differences among measurement approaches; it does not supply a universal yield stress for fermentation broths.

Supplementary teaching calculations: Python calculation and results as CSV. The data description records assumptions, units and execution.

Terms in this chapter