Net increase, gross growth and measurement signal
Specific net increase of biomass inventory M_X is μ_net = (1/M_X)·dM_X/dt, once incoming and outgoing biomass are handled separately. Its unit is h⁻¹ when time is in hours. This is a relative rate: gaining 1 g/h has a different meaning for 2 g and 200 g initial biomass.
For viable biomass, μ_net may represent proliferation minus loss. Dry mass does not automatically separate living and dead material. Optical density is an optical signal requiring its own calibration; cell size, aggregation and measurement range can alter its relationship to biomass. Always report the measurement basis of a growth rate.
A rate fitted to five dry-mass observations is neither automatically maximum specific growth rate μ_max nor a pure division rate. μ_max is a model parameter with particular assumptions. An approximately exponential interval alone does not identify it.
Correct concentration slopes for dilution
Because M_X = X·V, between withdrawal events d ln M_X/dt = d ln X/dt + d ln V/dt. With cell-free feeding and no biomass removal, μ_net = d ln X/dt + F/V when feed is the only volume change. This follows from the product rule rather than an additional growth hypothesis.
Suppose log biomass concentration increases at 0.10 h⁻¹ while F/V = 0.03 h⁻¹. Biomass inventory then increases at 0.13 h⁻¹. Ignoring dilution underestimates growth. Evaporation, base addition or other volume changes require the complete dV/dt.
A representative sample reduces mass and volume in the same proportion. Concentration does not jump, but biomass inventory does. Fitting across uncorrected mass jumps interprets sampling as biological loss. Segment the record or explicitly model discrete withdrawals.
Reproduce a logarithmic fit
The synthetic batch has constant 2 L volume, no withdrawals and observations at 0, 2, 4, 6 and 8 h. Initial concentration is assumed to be 1.5 g/L and the generating rate 0.20 h⁻¹. Deterministic multipliers 1.00, 1.02, 0.98, 1.01 and 0.99 create reproducible deviations from a smooth curve. They do not represent a validated real error distribution.
Fit ln X_i = a + μ·t_i + e_i. The slope equals the sum of products of centred time and log observations divided by the sum of squared centred times. The intercept is mean log concentration minus slope times mean time. A short standard-library function performs the calculation.
The result is μ = 0.198502 h⁻¹ and a = 0.411356. Consequently fitted X₀ is exp(a), rather than an imposed value of exactly 1.5 g/L. Doubling time is ln(2)/μ = 3.491884 h. The difference from the generating rate is consistent with the deliberately perturbed observations.
What fitting uncertainty includes
Under the ordinary linear regression model, the slope standard error is 0.002755 h⁻¹. It describes conditional variation within the selected model, with five observations and three residual degrees of freedom. It excludes balance uncertainty, timing error and unrecognised method changes. It also excludes uncertainty introduced by selecting whichever fitting window appears most favourable.
Taking logarithms changes the error model. Equal weighting on ln X corresponds more closely to relative than constant absolute concentration errors. With nearly constant absolute measurement error, nonlinear fitting on the original scale may be more appropriate. Zeros, negative blank-corrected values and observations below quantification limits cannot be legitimately logged by substituting an arbitrary small value.
The NIST explanation of linear least-squares regression describes the method. Its biological interpretation remains limited by the measurement basis and experiment.
Select fitting windows without inventing growth
A fit spanning lag, growth and decline phases gives a composite slope. It may be arithmetically correct without representing a single physiological phase. Record the time window and its justification: process events, stable measurement conditions and the biological behaviour actually being investigated.
Examine residuals against time and predicted value. Systematic curvature suggests an unsuitable functional form or a time-dependent change. A high coefficient of determination does not resolve this. Five observations provide limited evidence; a complicated model may fit almost any small dataset without adding knowledge.
Exercise: Compare adjacent two-point slopes with the global fit. They fluctuate more because each depends on only two perturbed measurements. This does not establish oscillating metabolism. Distinguishing biological dynamics from differencing noise requires an appropriate measurement and time-resolution model.
Use the estimate for a bounded decision
A rate near 0.20 h⁻¹ can support timing estimates within the observed range of the same model process. It cannot automatically describe another strain, temperature or substantially higher biomass concentration. Numerical precision does not protect against inappropriate transfer.
Seed-train planning additionally requires the actual cell quantity needed; initial recovery loss and transfer efficiency belong in the inventory balance. Calendar duration can include thawing, adaptation, analysis and waiting, not just biological growth. See seed-train timing.
Consumption models connect growth rate to independently balanced substrate uptake. A good growth curve alone does not establish carbon requirements for maintenance or by-products. Continue with substrate uptake and maintenance models.
A complete case with increasing volume
Consider an additional synthetic four-hour feeding interval. Initially the reactor contains 20 g biomass in 5 L. The model has no biomass input, withdrawal or decay. Net relative increase is fixed at 0.15 h⁻¹. Final biomass is therefore 20 × exp(0.15 × 4) = 36.4424 g. Meanwhile cell-free feed increases liquid volume to 6 L. Concentration rises from 4.000 to 6.0737 g/L.
A two-point calculation using concentration alone gives ln(6.0737/4.000)/4 = 0.10442 h⁻¹. This is not the imposed biomass-mass growth rate. The missing correction is ln(6/5)/4 = 0.04558 h⁻¹, giving 0.15000 h⁻¹ when added. For this finite window, use logarithmic volume change. A single initial F/V value cannot exactly replace the integrated correction when V varies. This follows from the balance rather than from any particular organism.
The same result can be obtained directly from total inventories. This is often clearer when a reliable volume is available at every sampling time. However, volume should not come from a balance that was itself closed using the growth assumption being tested. Otherwise the apparently independent growth check becomes partly circular. In this teaching case, the volume trajectory is explicitly prescribed and calculated independently of the biomass equation.
For a real analysis, prepare a table containing time, concentration, volume, total biomass and documented withdrawals. Then identify the transformed quantity clearly: log concentration or log inventory. If two reports give different rates, compare this measurement basis before inferring physiological change. Discrete samples require event corrections; continuous biomass removal requires the corresponding term in the dynamic balance. Both issues are introduced in analysing fed-batch data.
Treat sampling as an event rather than growth
A representative withdrawal changes total biomass abruptly without changing concentration in the remaining ideally mixed liquid. Removing 0.25 L from 5.00 L leaves 95% of the previous biomass in the reactor. Log inventory therefore jumps by ln(0.95). A model that ignores withdrawal must incorrectly explain this jump through a change in biological growth. The effect is especially apparent when relatively large samples are taken from small reactors.
For a simple model with constant μ and entirely representative withdrawals, M_end = M_start × exp(μT) × ∏(1 − f_j), where f_j is the fraction of liquid removed immediately before each event. Therefore μ = [ln(M_end/M_start) − Σln(1 − f_j)]/T. These factors do not represent additional biomass formation; they describe the fraction of the existing population retained within the boundary. The expression does not apply unchanged to enriched or selective outputs.
One 5% withdrawal during a four-hour window reduces the uncorrected inventory estimate by −ln(0.95)/4 = 0.01282 h⁻¹ relative to the correct rate. An imposed model rate of 0.15 h⁻¹ would therefore appear as 0.13718 h⁻¹. In this particular constant-exponential model, exact sampling time does not alter the overall multiplicative factor. If μ varies with time or withdrawal changes culture conditions, this simplification no longer describes the complete trajectory.
Show measured inventory separately from any event-corrected model quantity. Otherwise a corrected curve can appear to be a direct measurement of biomass that was never actually present in the reactor. Harvest planning requires the real remaining inventory. Estimating relative biological increase may instead call for event correction. Both quantities are useful if their meanings remain explicit. Equating them would confuse the amount of material available with the question of how it grew.
Compare cell count, dry mass and optical signals
Growth is not one instrument-independent number. When mean cellular mass changes, cell count and dry mass can increase at different relative rates. If aggregates form, the number of counted objects may fall while cellular material increases. An optical signal can be affected by changes in size, shape or scattering. The first question in a method comparison is therefore not which instrument is “right”, but which quantity each method determines under which conditions.
An original numerical case illustrates the distinction. A population increases from 1.0 × 10⁹ to 1.8 × 10⁹ cells over four hours, while total dry mass rises from 0.20 to 0.45 g. Count-based net increase is ln(1.8)/4 = 0.14695 h⁻¹, whereas mass-based increase is ln(2.25)/4 = 0.20273 h⁻¹. Mean mass per counted cell rises from 0.20 to 0.25 ng. This is mathematically consistent. Establishing whether a real series reflects such a size change or measurement bias requires further observations.
The accessible original study by Ou and colleagues on bacterial flow cytometry illustrates why counting method, sample preparation and reference method need separate consideration. Its E. coli mixtures do not establish performance for every culture. Membrane properties and colony formation are also different measurement targets. No experimental values from that study are used in this calculation; the numbers belong solely to the original teaching example.
A useful parallel comparison uses matched sampling times and documents dilution, sample preparation, working range and the definition of a counted object. If only one method reaches saturation beyond its established range, that is not evidence of a biological plateau. Conversely, a reproducible change in the ratio of two independently suitable measurements may justify investigating cell size, composition or aggregation. The chapter on inoculum quality connects these measurement distinctions with an actual transfer decision.
Make the influence of individual points visible
A fitted line can depend more strongly on one endpoint than its smooth appearance suggests. Observations far from the mean time have greater leverage on slope. This is not inherently a problem: early and late measurements provide information about the overall increase. It does mean that a misassigned endpoint can change the estimated rate substantially. The appropriate response is to examine the observation and its origin rather than removing it simply because it is influential.
For the existing five-point example, perform a simple sensitivity calculation: fit the line five times, omitting a different time on each occasion. These results show dependence on individual observations. They are not five independent biological replicates because four data points overlap between fits. Their spread consequently does not directly measure biological reproducibility. Their value is in fault finding and transparent assessment of model dependence.
A second check introduces a known disturbance. Multiplying the final concentration by 1.10 shifts its log value by ln(1.10). For times 0, 2, 4, 6 and 8 h, Σ(t − t̄)² = 40 h². The fitted slope therefore increases by 4 × ln(1.10)/40 = 0.009531 h⁻¹. The same relative error at the middle time does not directly change slope in this symmetric, unweighted fit, although it changes the intercept and residuals. This is an algebraic property of the selected arrangement.
An unusual observation should not automatically be deleted because the remaining curve looks better. It may represent a real state change, a documented analytical error or an unresolved finding. Where helpful, report both fits and explain which is used for the question at hand. In a planned experiment, sensitivity analysis can indicate where extra independent samples would be informative. It does not justify retrospectively retaining only points that produce the desired growth rate.
Translate a rate into a conditional time to target
For constant relative net increase, time to target is T = ln(M_target/M_start)/μ. The equation is useful because it separates the required multiplication factor from the rate. It assumes that the rate remains appropriate throughout the interval and that there are no additional inputs or outputs. A rate measured early in cultivation does not become a reliable late-stage forecast merely by extending the same exponential curve. State the physiological and technical limits of the projection.
A fictional culture must increase from 50 to 200 g biomass. At μ = 0.20 h⁻¹, the calculated time is ln(4)/0.20 = 6.931 h. Using an explicitly assumed scenario range of 0.18 to 0.22 h⁻¹ gives times from 6.301 to 7.702 h. This is not a statistical prediction interval; it is sensitivity to three stated rates. An additional initial loss of 10% extends the central scenario to ln(200/45)/0.20 = 7.458 h.
Calendar planning also includes activities for which the growth assumption may not apply: preparation, sample processing, release decisions and transfer. If the culture continues growing while it waits, estimate or measure the delivered quantity at the actual transfer time. If it leaves the demonstrated physiological range, simple extrapolation may become inappropriate. A scheduling allowance therefore does not mean the culture can wait indefinitely. Operational planning and the biological timeline must agree.
The next stage ultimately needs more than total target biomass: concentration must be compatible with the volume that can actually be transferred. Sufficient total material may be spread through too much liquid. An adequately concentrated sample may still come from a culture of uncertain origin. Connect the growth calculation to transfer quantity, culture history and scheduling. The result then remains a decision aid within a complete handover case.
Do not equate net increase with cell division
A net cell count describes how many cells remain within the counting method's definition. It does not count every division that occurred. In the simple model dN_v/dt = (μ_g − k_d)N_v, μ_g describes formation of viable cells and k_d represents proportional loss from that class. Observed net increase is μ_net = μ_g − k_d. A constant viable inventory can therefore reflect either limited activity or substantial formation accompanied by substantial loss. Endpoint counts alone cannot distinguish these cases.
In an original example, let μ_g = 0.20 h⁻¹ and k_d = 0.05 h⁻¹. The viable population increases at a net rate of 0.15 h⁻¹. Under constant conditions it grows by exp(0.60) = 1.822 over four hours. Its net population doubling increment is correctly calculated as 0.60/ln(2) = 0.866. This does not mean that each individual cell divided 0.866 times. Such an interpretation confuses a population quantity with events in individual cells.
Dry mass may require a different loss model. A cell classified as nonviable by a particular assay does not immediately disappear from measured dry mass. Lysis can move material from the particulate to the dissolved fraction. Different methods may consequently have different effective balance boundaries. Do not add a decay term solely because it improves a fit; first identify which measurable fraction the term actually removes.
A report should therefore use descriptions such as “net rate based on viable cell count during hours 2–6” when that is what was evaluated. Mechanistic statements about division or death require additional suitable observations. Net doublings in culture history follow the same reasoning. A shared definition keeps growth analysis, seed-train records and cell-bank documentation consistent and avoids apparent contradictions caused only by different meanings.
Worked case: three trajectories with the same final concentration
Three synthetic four-hour trajectories finish at 4 g/L biomass after starting at 2 g/L, but their liquid volumes differ. This permits direct comparison of concentration and inventory calculations. Assume no biomass input or output. The table presents a numerical comparison rather than observed differences between cultures.
| Question | Calculation or finding | Meaning for the decision |
|---|---|---|
| A: constant volume | 2 L → 2 L; biomass 4 g → 8 g. | Inventory growth is ln(2)/4 = 0.17329 h⁻¹, equal to concentration growth. |
| B: increasing volume | 2 L → 3 L; biomass 4 g → 12 g. | Inventory growth is ln(3)/4 = 0.27465 h⁻¹ despite identical final concentration. |
| C: decreasing volume | 2 L → 1.5 L; biomass 4 g → 6 g. | Assuming only water leaves, inventory growth is ln(1.5)/4 = 0.10137 h⁻¹. |
| Shared concentration calculation | ln(4/2)/4 = 0.17329 h⁻¹ in all cases. | This calculation alone does not distinguish the three biomass formation quantities. |
| Quantity decision | Formation is 4 g, 8 g and 2 g respectively. | The next stage needs actual available material, not concentration alone. |
| Model limit | The numbers explicitly assume no biomass output. | Cell loss, sampling or selective retention requires the complete balance. |
A useful solution identifies the quantity used in each trajectory and explains the volume correction. These are average logarithmic inventory rates over four hours, not evidence of constant instantaneous rates between endpoints. If liquid loss in C were broth rather than pure water, biomass would also leave and the stated calculation would be insufficient. Such counterquestions make equation checking useful by identifying the extra information required for real data.
Data and calculation
Every observation in this case is explicitly synthetic. These files do not describe a real culture or prescribe operating conditions. They can be analysed locally; the website sends no calculation to an external server.
The Python script uses only the standard library. It regenerates the datasets from stated assumptions and checks the material balances. The solution file also contains numerical results. Rounding differences in displayed tables are not process losses.
The supplementary short cases can be recalculated separately: Python, CSV, JSON, explanatory notes.
Terms in this chapter
33 terms explained in the glossary
- Assay (reported content)
- Biomass
- Calibration
- Cell counting
- Coefficient of determination
- CSV file
- Degrees of freedom
- Density
- Doubling time
- Evaporation
- Experimental factor
- Extrapolation
- Fed-batch culture
- Forecast
- Harvest
- Inoculum
- Least squares
- Light scattering
- Linear regression
- Material balance
- Material inventory
- Metabolism
- Net growth rate
- Optical density
- Prediction interval
- Product recovery
- Representative sample
- Response variable
- Sensitivity analysis
- Standard error
- Statistical residual
- Substrate
- Transfer efficiency