Browse all terms · 792

Jump to an entry using the letters or the term directory. Your browser’s find function also searches every explanation.

A

Absolute pressure

Absolute pressure is referenced to a vacuum. It is the pressure basis required for ideal-gas equations and many property relationships. A value expressed only in bar does not identify that reference. The number and the explicit label “absolute” therefore belong together in a state description.

A sensor reading of 0.20 bar gauge at an atmospheric pressure of 0.98 bar corresponds to 1.18 bar absolute. Inserting 0.20 bar into an ideal-gas equation substantially changes the calculated amount of gas. A negative relative pressure can still correspond to positive absolute pressure. A pressure reading alone establishes no permissible equipment load; design limits and their reference basis must be considered separately.

Foundations: OpenStax College Physics 2e: Gauge pressure and absolute pressure

Used in these chapters · 9
Back to the term directory

Acceptance criterion

Related search terms: acceptance criteria

An acceptance criterion specifies which result or behaviour is sufficient for a particular assessment. It may concern a numerical range, minimum performance or observable function. Define the measurand, conditions and decision rule together.

For a mixing trial, specify the deviation to be achieved at the relevant measurement locations. Choosing a more favourable limit afterwards does not erase an earlier failure. Derive criteria from intended use and relevant consequences rather than from whichever result happens to be obtained.

Used in these chapters · 7
Back to the term directory

Access authorisation

Related search terms: authorization, authorisation, access authorization

Access authorisation in IT systems grants or checks permission to access particular resources or functions. It concerns which action an identified entity is allowed to perform. A known identity alone does not justify unlimited rights.

Bioreactor control may distinguish reading, starting runs, editing recipes and managing accounts. Align permissions with duties and responsibilities. Technical permission nevertheless does not replace any required scientific assessment of the action’s process consequences.

Foundations: Authorization

Used in these chapters · 1
Back to the term directory

Acid-neutralising capacity

Related search terms: ANC

Acid-neutralising capacity describes a sample’s ability to neutralise added acid under a specified procedure. The USGS method convention distinguishes ANC of an unfiltered sample from alkalinity of a filtered sample.

Reactive particulate constituents can consequently produce different results. This methodological distinction is documented alongside filtration, endpoint evaluation and unit. It does not justify treating a filtered clear-effluent value as interchangeable with an unfiltered sludge result.

Foundations: National Field Manual for Collection of Water-Quality Data

Used in these chapters · 2
Back to the term directory

Activated-sludge process

Related search terms: Activated sludge

Activated-sludge treatment converts wastewater constituents using suspended microbial communities. It combines biological reaction zones with biomass separation or retention and controlled excess-sludge removal.

Depending on configuration, aerobic, anoxic and anaerobic zones serve different purposes. Sludge contains biomass and other solids rather than exclusively active cells. Recycle, solids retention time and loads are assessed together; conventional operation is not sterile cultivation.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Activity coefficient

Related search terms: activity coefficients

An activity coefficient connects a substance’s activity to its concentration or molality under a specified standard-state convention. It describes nonideal thermodynamic behaviour and depends on factors including composition and temperature.

A value estimated for a simple salt model is not automatically suitable for a complex medium. It must not be adjusted arbitrarily to force an incomplete balance to match a desired pH result.

Foundations: 11.4 Colligative Properties · Quantities, Units and Symbols in Physical Chemistry (IUPAC Green Book)

Back to the term directory

Adenosine triphosphate

Related search terms: ATP

A nucleotide comprising adenine, ribose and three phosphate groups, abbreviated ATP. Cells use reactions coupled to ATP for processes including biosynthesis and transport. Hydrolysis to adenosine diphosphate and inorganic phosphate can provide free energy through the overall reaction; breaking a bond alone does not release energy.

Available reaction free energy depends on conditions and the activities of the participating substances. A measured ATP inventory is also not an ATP turnover rate. A carbon balance or substrate-based maintenance coefficient therefore does not determine ATP formation and consumption without additional metabolic assumptions.

Foundations: 6.4 ATP: Adenosine Triphosphate, Biology2e

Used in these chapters · 2
Back to the term directory

Adherent cells

Related search terms: Anchorage-dependent cells

Adherent cells attach to a surface; many also require attachment for normal growth and maintenance of function. This interaction involves cell-surface proteins and components of the extracellular environment. Surface characteristics consequently become biological process variables extending beyond the amount of available area. Not every cell that adheres is strictly anchorage-dependent under all conditions.

Available growth area, cell density and cell contacts can limit expansion. Adding more medium does not automatically create additional growth capacity. Detachment for further culture or harvest is also a biological intervention that can affect function and recovery. A suitable surface must therefore support both the intended expansion and the subsequent use of the cells.

Used in these chapters · 4
Back to the term directory

Adjustment

Adjustment changes a measuring system so that its indications correspond to prescribed reference values. For a sensor, this may involve changing the zero point or slope of its response curve. A dependable determination of the deviation must come first; an unexpected process reading alone is insufficient justification for adjustment.

Distinguishing calibration from adjustment shows how the instrument performed before intervention and what performance was achieved afterwards. Both states should remain traceable, and the result needs checking after the change. Numerical correction cannot indefinitely compensate for ageing, dirty membranes or unsuitable installation. Large or repeatedly changing corrections therefore warrant investigation of the cause rather than the display alone.

Used in these chapters · 21
Back to the term directory

Adsorption

Related search terms: adsorptive, adsorption loss

Adsorption is enrichment of a substance at a surface or interface. In bioprocessing it can deliberately bind product to chromatography material or undesirably retain product on membranes, tubing or vessels. It differs from uptake into the bulk of a material.

Relevant adsorbed material is a separate inventory in the balance. Later release can change a product stream without representing new biological formation. Reversibility and binding strength depend on substance, surface and conditions.

Foundations: CaptivA HF Protein A Affinity Resin · Dialysis Methods for Protein Research · Protein preparation handbook

Used in these chapters · 12
Back to the term directory

Affinity chromatography

Related search terms: affinity capture

Affinity chromatography uses suitable binding between a target and a ligand attached to the stationary phase. Following loading, selected unbound components can be removed and bound material recovered under appropriate conditions.

Suitability depends on actual product and matrix. Strong binding alone guarantees neither sufficient selectivity, complete elution nor preserved function. A process comparison establishes conditions, capacity, losses and product state together.

Foundations: Protein preparation handbook

Back to the term directory

Agarose gel electrophoresis

Separation of DNA through a gel matrix in an electric field. Comparable linear fragments can be sized approximately against a suitable standard.

Band position alone does not identify sequence. Different plasmid conformations can also affect migration, so size comparisons require an appropriate reference basis.

Foundations: Addgene

Back to the term directory

Agitation speed

Related search terms: Impeller rotational speed, Stirrer speed, rpm

Agitation speed states how many revolutions an impeller shaft completes per unit time. Displays commonly use revolutions per minute, or rpm, whereas engineering equations often require revolutions per second, expressed as s⁻¹. Divide the numerical rpm value by 60: 300 rpm equals 5 s⁻¹. Confusing these units causes substantial errors when calculating impeller tip speed or power.

The effect depends on impeller diameter and shape, vessel geometry, working volume, aeration and medium properties. Equal rotational speeds therefore do not establish equal mixing or cell stress. During scale-up, speed must be derived from suitable process criteria and verified experimentally; it is not a universal constant to transfer unchanged from laboratory to production.

Used in these chapters · 8
Back to the term directory

Agitator shaft

An agitator shaft transfers torque from the drive to one or more impellers and maintains their intended positions. It experiences bending and fluctuating hydrodynamic loads as well as torsion. Length, diameter, bearing arrangement and impeller placement therefore jointly determine acceptable mechanical operating conditions.

Extending a shaft for a taller vessel cannot be justified simply by retaining the same rotational speed. Natural frequencies, deflection and loads at the coupling or seal must suit the changed geometry. A matching shaft diameter also does not establish interchangeability: connection dimensions, material, surfaces and the installation arrangement matter. The shaft is a designed component of the complete agitation system, rather than an arbitrarily scalable connecting rod.

Back to the term directory

Air removal in steam sterilisation

Related search terms: air purging

Air removal clears air and other non-condensable gases from regions intended to receive steam treatment. These gases can obstruct contact with saturated steam and prevent total pressure from corresponding to the expected steam temperature. Suitable pipe routing, vent locations and cycle steps appropriate to the system support their removal.

Visible steam leaving an open connection does not prove that all internal spaces are free of trapped air. Dead-ended spaces, complex assemblies and porous loads need particular consideration. Effective air removal is evaluated together with temperature distribution and load configuration. The appropriate procedures and test scope differ between autoclaves and permanently connected equipment. General steam settings therefore cannot replace assessment of the actual system and its intended use.

Back to the term directory

Airlift bioreactor

An airlift bioreactor drives liquid circulation through a difference in gas content between two connected regions. The more strongly aerated riser has a lower average mixture density than the downcomer, creating a circulation loop. A draft tube can separate these regions inside one vessel; an external-loop arrangement connects separate flow passages.

The design combines gas supply and circulation without a mechanical impeller inside the culture chamber. Performance nevertheless depends on geometry, gas disengagement, hydraulic resistance and broth rheology. High viscosity or excessive gas carry-under can weaken circulation. Describing an airlift as gentle does not establish biological suitability: bubbles, narrow passages and local velocity gradients can still stress sensitive cells and aggregates.

Used in these chapters · 1
Back to the term directory

Alkalinity

Alkalinity describes the ability of a defined water sample to neutralise acid according to a specified method. It is often expressed in mmol charge equivalent L⁻¹ or mg L⁻¹ as CaCO₃; the latter does not assert that this mass of calcium carbonate is dissolved.

It is not pH. In an appropriate carbonate balance, carbon dioxide exchange can change pH without by itself changing total alkalinity. Filtration, titration evaluation and additional buffer systems limit comparability between analytical results.

Foundations: National Field Manual for Collection of Water-Quality Data · Alkalinity and Water

Used in these chapters · 7
Back to the term directory

Allele

An allele is a sequence variant at a particular genomic location. That location may belong to a gene but need not be a protein-coding region. The number of alleles present at a location depends partly on the chromosome complement; assuming exactly two is inappropriate for many production organisms.

For a production cell line, a variant description requires the location, reference sequence and population examined. Detecting a variant establishes neither increased productivity nor its cause. A cell-bank comparison should distinguish the sequence finding, its frequency and the measured process phenotype.

Foundations: NHGRI: Allele

Back to the term directory

Allocation in life cycle assessment

Related search terms: allocation, LCA allocation

Allocation in life cycle assessment apportions shared material and energy flows and environmental contributions among multiple product functions. An example is assigning emissions from a shared utility. This differs from assigning available equipment or staff to operational tasks.

The accounting approach determines whether partitioning can be avoided and which justified relationships provide allocation factors. Physical and economic factors may produce different results. State the method and assumptions, apply them consistently, and examine influential differences through sensitivity analysis.

Foundations: Life Cycle Assessment & EF methods · Product Life Cycle Accounting and Reporting Standard, chapter 9: Allocation

Used in these chapters · 2
Back to the term directory

Allowlist

Related search terms: allowlist

An allowlist explicitly identifies elements permitted under a defined policy. Depending on the application, these can be programmes, communication counterparts or other objects. A list becomes effective only when the relevant system actually applies its rules.

For a bioreactor platform, a bounded list of permitted connections can describe intended data communication. Changes must preserve necessary workflows. Inclusion alone does not constitute comprehensive scientific or security assessment of every property of the listed object.

Foundations: Allowlist

Back to the term directory

Alternating tangential flow (ATF)

Related search terms: ATF

ATF denotes periodically reversing flow along a membrane. In common perfusion systems this movement connects the bioreactor with an external retention unit. Net harvest through the membrane differs from the oscillating loop quantity.

Flow reversal does not establish universally lower cell stress. Pump, geometry, medium and operating state affect actual exposure. Comparing retention arrangements requires appropriate cell, product and loss balances under stated conditions.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems · XCell ATF Systems

Used in these chapters · 1
Back to the term directory

Alternative splicing

Alternative splicing allows a precursor RNA to give rise to different mature RNA variants by joining selected regions in different combinations. A single gene can therefore produce multiple transcript variants. These may yield different protein forms; detecting an RNA variant does not necessarily establish the presence of a stable protein.

In cell-line characterisation, this explains why measuring total gene expression may be insufficiently specific for the intended product form. The analytical question should distinguish total transcript, a particular variant and the protein actually present. Transcript findings do not replace product-identity and functional measurements.

Foundations: NHGRI: Alternative splicing

Back to the term directory

Amino acid

Related search terms: Amino acids

An organic compound containing amino and carboxyl functions; protein-forming amino acids are building blocks of proteins. Their side chains differ and influence chain properties. The commonly named 20 standard amino acids are not all amino acids occurring in nature.

In media they can provide different material and nutritional contributions. Essential must be interpreted for the organism and context. Total amino-acid quantity does not automatically describe balanced supply or the concentration of every individual component.

Foundations: Amino acids

Used in these chapters · 9
Back to the term directory

Amount concentration

Related search terms: molarity, formal concentration

Amount concentration c = n/V relates the amount of a specified component to final solution volume, commonly in mol/L or mmol/L. It differs from molality, which uses solvent mass.

A formal concentration follows from total added amounts. It need not equal the concentration of a free species when dissociation, binding or precipitation matters. Temperature and final-volume determination belong in the documented preparation basis.

Foundations: 3.3 Molarity

Used in these chapters · 2
Back to the term directory

Amount of substance

Related search terms: molar amount

Amount of substance describes an inventory of specified entities on the molar scale. Its unit is mol; the entity may be a molecule, ion or formula unit. For a pure substance, n = m/M relates amount to mass and molar mass.

In a medium, specify whether a value means moles of salt, calcium or carbon atoms. Chemical formulae connect these quantities, but they are not interchangeable without stoichiometric conversion.

Foundations: 3.3 Molarity

Used in these chapters · 5
Back to the term directory

Amplicon

Related search terms: PCR product

Nucleic-acid segment produced by amplification. In ordinary PCR, template and primer pair define the targeted region.

Expected fragment size is only one verification criterion. A signal may contain unintended products; interpretation must match the detection method and controls.

Foundations: Addgene

Back to the term directory

Anaerobic

Anaerobic means without molecular oxygen. In biological nutrient-removal practice, the term is often used more narrowly for zones also lacking nitrate or nitrite as available electron acceptors.

During digestion, different groups of organisms cooperate in oxygen-free metabolic chains. Anaerobic means neither sterile nor biologically inactive. Which additional electron acceptors are excluded is specified for the particular process rather than mixing different disciplinary conventions.

Foundations: Nutrient Control Design Manual · How Does Anaerobic Digestion Work?

Used in these chapters · 6
Back to the term directory

Anaerobic ammonium oxidation

Related search terms: Anammox

Anammox is a biological conversion in which ammonium reacts with nitrite under oxygen-free conditions to produce predominantly gaseous nitrogen. Growth and additional nitrogen products belong in the complete process stoichiometry.

It is not simply complete aerobic nitrification followed by heterotrophic denitrification. Balances therefore require their own reaction terms and boundary conditions. Suspected anammox activity inferred from a total-nitrogen residual is not uniquely identified without additional evidence.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Anaerobic digestion

Related search terms: Digestion

Anaerobic digestion breaks down organic material through an oxygen-free microbial reaction chain and can produce biogas. Hydrolysis, fermentative steps and methane-forming conversions involve different interacting groups of organisms.

Methane formation is particularly associated with methanogenic archaea and must not simply be attributed to all participating bacteria. Substrate conversion, gas quantity and remaining digestate are balanced together. Higher organic loading does not guarantee proportionately greater stable gas production.

Foundations: How Does Anaerobic Digestion Work? · Nutrient Control Design Manual · Microbiology 4.6 Archaea

Used in these chapters · 2
Back to the term directory

Analysis of variance

Related search terms: ANOVA

Analysis of variance partitions variation in observations according to a specified model. A linear experimental model can thereby describe factor, block and residual contributions.

The calculation is matched to design, coding and dependence. Different sum-of-squares decompositions are not automatically equivalent for unbalanced data. A table entry therefore does not replace identifying the particular comparison estimated and the error assumptions required by a test.

Foundations: Testing missing or misspecified model terms

Back to the term directory

Analytical recovery

Related search terms: recovery factor

Analytical recovery describes the fraction of a known or added analyte quantity detected through a defined investigation procedure. State whether concentration, amount or mass is compared and which steps are included.

It is not automatically a process yield. Preparation may lose analyte or change its signal. A recovery correction needs suitable investigation of the matrix and relevant concentration range rather than an assumed favourable factor.

Used in these chapters · 3
Back to the term directory

Aneuploidy

Aneuploidy denotes gain or loss of individual chromosomes relative to a complete chromosome complement. It differs from a change involving entire chromosome sets. In cell lines, chromosome number and composition can vary between cells, so a single examined cell need not represent the whole population.

For production cells, the relevant reference is the characterised starting population. A change is assessed by its extent, frequency and relationship to the intended characteristics. Chromosome number alone predicts neither process performance nor a generally applicable release decision.

Foundations: NHGRI: Aneuploidy

Back to the term directory

Annuity present value factor

Related search terms: annuity present value factor

The annuity present value factor sums discount factors for n equal end-of-period payments. With constant i ≠ 0 it is [1−(1+i)⁻ⁿ]/i; at i = 0 it equals n.

It can represent modelled constant annual service payments. Maintenance peaks, price changes or beginning-of-period payments require an adjusted cash-flow series. The constant-payment assumption should therefore follow the project agreement or an explicitly named scenario.

Foundations: 11.3 Time Value of Money

Back to the term directory

Anoxic

In conventional biological wastewater treatment, anoxic denotes conditions without available molecular oxygen where oxidised nitrogen compounds such as nitrate or nitrite may act as electron acceptors.

The term is tied to this process context and distinguished from anaerobic zones lacking these acceptors. One low oxygen measurement describes neither the full spatial distribution nor automatically the intended conversion. Nitrate, substrate and reaction evidence are considered additionally.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Anti-windup

Anti-windup comprises measures that prevent or remove excessive integral accumulation when actuator output is limited. If a dosing pump already runs at maximum flow, a growing integral term cannot create additional physical action. It may nevertheless demand excessive output for too long afterwards and cause overshoot.

Suitable methods conditionally stop integration or feed the effective actuator output back into the integrator. Cascades and combined feedforward arrangements require the actual limits to be represented correctly. Anti-windup does not create extra equipment capacity or repair an incorrect control direction. It improves recovery from saturation and can support transfer between manual and automatic operation when controller states are tracked appropriately.

Used in these chapters · 1
Back to the term directory

Anticodon

An anticodon is a sequence of three nucleotides on a transfer RNA. During protein synthesis, that RNA recognises a corresponding messenger-RNA codon and contributes the associated amino acid to the growing chain. Codon and anticodon belong to different molecular regions; strand direction must be specified when complementary sequences are written down.

The term helps explain the relationship between an introduced coding sequence and its host’s translation machinery. DNA sequence alone does not fully describe protein production. A suspected translation limitation requires suitable biological evidence and cannot be diagnosed solely from an unusual fermentation curve.

Foundations: NHGRI: Anticodon

Back to the term directory

Antifoam

Related search terms: Defoamer

A substance or formulation used to reduce foam formation or break existing foam. In bioprocesses its effect depends on formulation, medium, dose and operating state.

Antifoams are also process inputs. Contributions to liquid inventory, organic carbon or downstream processing may matter despite their auxiliary role. A generic label does not replace assessment of the actual formulation and intended use.

Foundations: Setting up and modelling of overflowing fed-batch cultures of Bacillus subtilis for the production and continuous removal of lipopeptides

Used in these chapters · 10
Back to the term directory

Apoptosis

Related search terms: Programmed cell death

Apoptosis is a regulated form of cell death involving coordinated internal dismantling processes. Typical features include changes in cell shape, the nucleus and membrane organisation; many, but not all, associated pathways use caspases as execution enzymes. It therefore differs from simply observing that a cell is no longer viable and does not encompass every form of regulated cell death.

In animal cell culture, loss of survival signals, nutrient stress or other burdens can favour these programmes. Early stages may not immediately involve loss of membrane integrity. The productive population can consequently be affected before a simple overall assessment shows a clear decline. Identifying the cause requires several consistent observations rather than a single non-specific signal.

Back to the term directory

Apparent viscosity

In simple shear, apparent viscosity is shear stress divided by shear rate at the evaluated point. Its unit is Pa·s.

For non-Newtonian fluids it depends on shear rate and potentially on history. A value without temperature, measurement conditions and sample state is therefore not a complete material characterisation. In simple shear it is τ/γ̇, with units of Pa s. A power law gives Kγ̇ⁿ⁻¹. Comparisons consequently require at least shear rate, temperature, sample condition and relevant loading history; quoting a single value without these conditions can misleadingly suggest that different materials behave alike.

Foundations: Viscosity

Used in these chapters · 2
Back to the term directory

Areal productivity

Related search terms: Area-based productivity

Areal productivity is formed or recovered quantity per explicitly defined area and time. For photobioreactors, light-entry area, wetted wall area and occupied ground area may be very different reference quantities.

The numerator must also be clear: net biomass formation, harvest and purified target product are not interchangeable. A geometrically smaller denominator raises the metric without additional production. Comparable statements require the same period, numerator and area basis.

Foundations: A Simple and Reliable Formula for Assessment of Maximum Volumetric Productivities in Photobioreactors

Used in these chapters · 2
Back to the term directory

Artificial intelligence

Related search terms: AI

Artificial intelligence includes technical approaches to tasks such as perception, learning, reasoning and deriving predictions or decisions. It encompasses several method families; machine learning is one of them.

In bioprocess engineering, the label does not establish measurement accuracy or permissible control authority. A system is assessed through its task, data, model limits and demonstrated performance. A conventional balance calculation or automatic data transfer does not become a learning model merely through automation.

Foundations: Artificial intelligence — CSRC Glossary

Used in these chapters · 1
Back to the term directory

Asepsis

Related search terms: aseptic technique

Asepsis comprises measures that prevent unwanted microorganisms from entering a protected process. In a bioreactor, particularly vulnerable steps include inoculation, medium addition, replacement of connected containers and removal of material. Closed lines, suitable filters and controlled connection procedures preserve a microbiological barrier established beforehand.

Aseptic technique does not remove contamination already present. A sterilised reactor can become contaminated through a single unprotected opening. Conversely, deliberately adding the production organism is an intended process step, not contamination. The assessment therefore distinguishes the organisms wanted in the process from unwanted organisms and identifies their possible entry routes. Asepsis protects the culture system; protection of personnel and the surrounding environment requires a separate assessment.

Used in these chapters · 24
Back to the term directory

Aseptic connector

Related search terms: sterile connector

An aseptic connector joins suitable sterile fluid paths while shielding their protected internal surfaces from the surroundings. Depending on its design, protective membranes may be removed in a controlled manner or dedicated contact surfaces joined in a specified sequence. The important property is the performance of the complete connection under its intended handling conditions.

Not every tubing coupling is an aseptic connector. A mechanically leak-tight connection can still trap microorganisms during assembly. Even a suitable connector must be used with approved mating parts, sterilisation conditions and process limits. Damaged protective surfaces, incorrect activation and tensile loads can compromise the barrier. The description also does not automatically imply safe disconnection after use; connection and disconnection may require different components or procedures.

Back to the term directory

Assay (reported content)

Related search terms: analytical assay, assay, Assay, assay content

In a reported-content context, assay is a method-dependent quantitative statement about the component examined. Its basis may be material as supplied or dry matter. Chromatographic area purity is not a mass fraction without suitable justification.

Formulation correction requires matching analyte, chemical form, method and reference basis. The number alone does not establish biological equivalence between raw materials and must not be double-corrected using an already included water adjustment.

Used in these chapters · 25
Back to the term directory

Assimilation

Related search terms: Nitrogen assimilation

Assimilation incorporates taken-up material into cellular constituents. In a nitrogen balance, nitrogen assimilation may describe ammonium-N entering newly formed organic biomass nitrogen.

This does not make the element disappear from the system. Only export of nitrogen-containing biomass across the chosen boundary contributes to external removal. Decay and mineralisation can partly reverse incorporation, so net and gross contributions must be distinguished.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

At-line measurement

At-line measurement analyses a sample removed from the process in close physical proximity to the equipment. A cell counter or metabolite analyser beside the bioreactor, supplied by an operator with a freshly collected sample, is a typical example. This proximity distinguishes the arrangement from analysis in a more distant laboratory.

At-line analysis can deliver results promptly and allows flexible instrument selection. Withdrawal, identification and handling nevertheless remain separate sources of error. A sample is not automatically unchanged because the instrument stands nearby. Gas loss, continuing metabolism or waiting before analysis can still affect it. Interpretation therefore needs both sampling and measurement times, together with relevant preparation steps.

Back to the term directory

Attenuation coefficient

Related search terms: Effective attenuation coefficient

An attenuation coefficient describes reduction of a specified radiation quantity along a path. In the simple exponential model I(z) = I₀ exp(−kz), k has units of inverse length.

In a scattering suspension, an empirical k also depends on measurement geometry. It is not automatically a pure absorption coefficient. Concentration, pigment state, wavelength range, wall and detector position therefore accompany the reported parameter.

Foundations: Temporal scaling of the growth dependent radiative properties of microalgae · Optimal optical conditions for Microalgal production in photobioreactors

Used in these chapters · 2
Back to the term directory

Audit trail

An audit trail is a protected, time-associated record of relevant actions affecting electronic data or system settings. It should show who changed what and when, together with the reason where appropriate. For example, it may document an operator changing a pH setpoint or reprocessing an analytical result.

It differs from an ordinary measurement trend: the trend depicts the process, whereas the history explains interventions and processing steps. Its usefulness depends on event coverage, distinct user accounts, synchronised time and effective access protection. A log table is insufficient if it can be altered unnoticed or relevant entries receive no assessment. Recording, retention and appropriate review therefore belong together.

Used in these chapters · 1
Back to the term directory

Autoclave

Related search terms: steam steriliser

An autoclave is a pressure-resistant apparatus in which a suitable load can be treated with moist heat under defined conditions. Increased pressure enables the required water or steam temperatures. For sterilisation, however, the treatment actually received by the load matters, not chamber pressure alone. Liquids, wrapped components and porous materials require different cycle designs.

Fill volume, container shape and arrangement influence heating and cooling. A cycle suitable for small bottles is therefore not automatically suitable for a filled laboratory reactor. Safe cooling is particularly important for liquids. Closed containers that have not been designed for the treatment must not be handled like open loads. Equipment limits and a procedure appropriate to the actual load determine safe and effective use.

Used in these chapters · 3
Back to the term directory

Autocorrelation

Related search terms: Serial correlation

Autocorrelation describes the statistical relationship of a quantity with time- or space-shifted values of itself. In a time series it may show that consecutive observations do not represent independent information.

Slow process dynamics, filtering and shared disturbances can generate this dependence. The number of stored one-second values must therefore not automatically be treated as a sample size of independent reactor states. Residuals are also checked for remaining temporal structure.

Foundations: Autocorrelation · Assessing independence of random errors

Used in these chapters · 1
Back to the term directory

Axenic culture

Related search terms: Axenic cultivation

An axenic culture contains the intended organism without accompanying foreign organisms. In microalgal work, this differs from a unialgal culture, which contains one algal species but may still contain bacteria. Such companions can supply nutrients, consume substrates or affect measurements and product characteristics.

Axenicity therefore describes the composition of the culture rather than simply the condition of its vessels and media. It must be assessed with appropriate evidence and within the limitations of the detection approach. An apparently normal-looking culture is insufficient proof. Conversely, removing natural companion organisms can change growth behaviour. Comparisons between axenic cultures and cultures containing associates must take these biological interactions into account.

Used in these chapters · 6
Back to the term directory

B

Bacteria

Related search terms: Bacterial cultures

Bacteria are single-celled organisms without a membrane-enclosed nucleus. Their metabolism supports widely different lifestyles; industrial cultures may consume sugars, organic acids or particular gases. Many production strains proliferate relatively rapidly, so nutrient demand, oxygen demand and heat release can change substantially during cultivation. Bacteria nevertheless do not form one uniform engineering process class.

Cultivation depends on the specific combination of species, strain and production objective. Oxygen may be required, tolerated or harmful. Protein secretion and the ability to generate particular product attributes also depend on the organism. Successful operation with one bacterium therefore provides no universal settings for others. Interpreting the relationship between supply, growth and product formation is more useful than transferring a standard recipe without biological justification.

Used in these chapters · 5
Back to the term directory

Bacterial endospores

Related search terms: endospores

Bacterial endospores are resistant survival forms produced by certain bacteria. They develop within a vegetative cell and permit survival under unfavourable conditions. Their specialised structure and greatly reduced metabolic activity make them more resistant to many stresses than the corresponding growing cells. Spore resistance can therefore determine the challenge used when establishing a sterilisation process.

Endospores are not a means of multiplication: one cell generally produces one spore, which can germinate when conditions become suitable. Not every bacterium forms endospores, and different spores do not have identical resistance. An organism suitable for challenging moist heat is consequently not automatically suitable for irradiation or chemical treatment. Fungal spores also require separate consideration because their characteristics differ.

Back to the term directory

Baffle

A baffle is a stationary internal element that deliberately changes vessel flow. In a stirred tank, vertical elements near the wall commonly restrict the liquid from rotating as a single body. This can direct more of the impeller's action into circulation and mixing instead of bulk swirling with a pronounced surface vortex.

Number, width, wall clearance and immersion depth affect both the flow pattern and power draw. Adding a baffle is therefore not a hydraulically neutral modification. Probes and other internals may also disturb the flow, but they are not automatically equivalent to defined baffles. Their arrangement matters when transferring a process, especially if two vessels show different degrees of swirling at the same rotational speed.

Back to the term directory

Base load

Related search terms: base load

Base load here means utility demand continuously present over a specified observation interval. It is a property of the named operating case, not necessarily an unchanging plant constant.

A campaign may have continuous cooling demand alongside short heating events. Changing the boundary for rooms, auxiliary systems or standby users changes the reported base load. Time scale and system boundary therefore belong to the value.

Foundations: Steam Accumulators

Used in these chapters · 1
Back to the term directory

Batch culture

In batch culture, the main nutrient inventory is supplied before cultivation; deliberate nutrient feeding during the growth phase is outside this operating mode. Consumption and metabolism progressively change the medium, so cells commonly pass through successive growth phases rather than maintaining a constant physiological condition.

Batch does not mean a hermetically sealed vessel: gas supply, pH correction and small analytical samples may still be necessary. It is useful for straightforward experiments and processes that tolerate the initial substrate concentration. However, excessive initial concentrations can inhibit growth, while later nutrient depletion or by-product accumulation limits performance. Comparing batches therefore requires comparable inocula, medium composition and harvest stages.

Used in these chapters · 2
Back to the term directory

Bed volume

Related search terms: resin volume, column volume, bed volumes

Bed volume is the geometrical volume of a packed chromatography bed, equal to cross-section times height for an ideal cylinder. Liquid quantities may be expressed as multiples of it, with the reference space explicitly stated.

Bed volume differs from mobile liquid volume in pores and interstices. Nominal residence time V/Q often uses the entire bed. Actual molecular residence and dead-volume corrections need additional geometrical and distribution information.

Foundations: CaptivA HF Protein A Affinity Resin

Used in these chapters · 1
Back to the term directory

Beta distribution

The beta distribution is a continuous family on the interval from zero to one with two positive shape parameters α and β. Its density may be symmetric, skewed or elevated towards the boundaries, depending on the parameters.

It can model bounded proportions when continuous values and the distributional assumptions are appropriate. Its mean is α/(α + β). An ordinary continuous beta distribution assigns no positive probability to the individual endpoints zero and one; actual endpoint masses therefore need separate treatment.

Foundations: Beta distribution

Back to the term directory

Binomial distribution

The binomial distribution describes the number of successes in n independent trials with the same success probability p. Its mean is np and variance np(1 − p).

For cell counting, the meaning of a trial and success must be justified. Dependent cells in aggregates or varying success probabilities do not satisfy the simple model assumptions. A binomial calculation therefore does not automatically provide the full uncertainty of biological sampling.

Foundations: Binomial distribution

Back to the term directory

Bioburden

Related search terms: microbial burden

Bioburden is the load of viable microorganisms on a material or surface, or in a liquid, for example before sterilisation. It is measured using an appropriate microbiological method and expressed relative to a defined quantity or area. The type of organism matters alongside its number: a small population of resistant spores can present a greater treatment challenge than a larger population of sensitive vegetative cells.

Results depend on sampling, recovery efficiency and culture conditions. A low measured burden therefore cannot exclude every undetected organism. Controlled raw materials and limited holding times help constrain the challenge presented to subsequent treatment. The deliberately high cell concentration of a production culture should not be confused with an unwanted initial microbial burden.

Used in these chapters · 3
Back to the term directory

Biocatalyst

Related search terms: Biocatalysts

A biocatalyst enables or accelerates a chemical conversion through biological catalytic activity. Bioprocess engineering may use isolated enzymes or whole cells for this purpose. Growth is not essential: a resting cell can remain catalytically active. Enzyme amount and the reaction rate actually achieved are different quantities.

Reactor selection therefore requires a distinction between growing cells, using an existing cellular enzyme system and operating an isolated-enzyme reaction. Loss of activity may have causes other than loss of biomass. Substrate access, product inhibition and stability require suitable measurements. Calling something a biocatalyst establishes neither unlimited reuse nor particularly low resource consumption for the complete manufacturing process.

Foundations: Noor et al.: The protein cost of metabolic fluxes · Serial et al.: Quantifying enzyme immobilization in porous carriers

Back to the term directory

Biochemical oxygen demand

Related search terms: BOD, BOD₅, BOD5

Biochemical oxygen demand describes biologically caused oxygen consumption of a sample under specified test conditions. BOD₅ denotes a defined five-day test duration, with the remaining method conditions forming part of the result.

The quantity depends on biological activity, temperature, sample treatment and whether nitrification is inhibited. It is therefore neither equivalent to COD nor identical to a real plant’s immediate aeration demand. Results from different test conditions are not assumed interchangeable.

Foundations: Biochemical Oxygen Demand and Water · Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Bioconversion

Conversion of a substance through biological activity, for example whole cells or isolated enzymes. The term emphasises conversion and does not necessarily require substantial growth of the biological catalyst.

Balance converted substrate, formed product and catalyst quantity separately. High conversion rate does not automatically imply high target-product yield when side reactions occur. State the reaction and biological agent with the claim.

Foundations: The protein cost of metabolic fluxes: prediction from enzymatic rate laws and cost minimization

Used in these chapters · 1
Back to the term directory

Biofilm

Related search terms: surface-associated microbial community

A biofilm is a microbial community organised on a surface or interface, often surrounded by a matrix produced by the organisms themselves. This matrix can retain cells, bind substances and alter the access of cleaning or disinfecting agents. Residual moisture, inaccessible sealing areas and aqueous systems left standing can favour its establishment.

A biofilm does not have to appear as a visible deposit. Released cells or fragments can repeatedly contaminate a downstream process even when an intervening liquid sample gives an unremarkable result. Prevention therefore begins with drainability, appropriate holding periods and effective cleaning. Simply increasing disinfectant concentration does not reliably solve the problem if the matrix or the poorly accessible contaminated surface remains in place.

Used in these chapters · 3
Back to the term directory

Biogas

Biogas is a gas mixture produced by anaerobic breakdown of organic material. Major constituents are methane and carbon dioxide; water and other components depend on the feedstock and process.

Its usable energy depends strongly on methane content and the stated gas reference conditions. Raw gas is not automatically suitable fuel for every engine or gas grid. Upgrading and use are assessed against the specific gas quality and application interface.

Foundations: How Does Anaerobic Digestion Work?

Used in these chapters · 6
Back to the term directory

Biological containment

Related search terms: containment

Biological containment combines barriers, suitable equipment and working practices to reduce unintended exposure to or release of biological material. It may include an immediate barrier at the operation and supplementary facility measures. The required arrangement follows the specific risk assessment.

A closed bioreactor alone therefore does not demonstrate complete containment throughout the workflow. Sampling, inlet and exhaust gas, transfers, waste and maintenance also belong within the assessed boundary. Containment limits release, whereas aseptic processing limits unwanted entry. These objectives can support one another, but one demonstration does not automatically establish both.

Foundations: Biosafety in Microbiological and Biomedical Laboratories, sixth edition

Used in these chapters · 2
Back to the term directory

Biological indicator

Related search terms: BI

A biological indicator contains a defined population of microorganisms with known resistance to the treatment being assessed. It is placed at a justified location to evaluate biological effectiveness. Suitable spore preparations are used for certain steam processes, for example. Selection nevertheless depends on the treatment, carrier material and actual challenge.

A negative growth result is meaningful only when the indicator, handling and subsequent evaluation were appropriate. An improperly stored indicator or an inactive starting population can produce a misleadingly favourable finding. Likewise, an indicator beside a vessel does not automatically represent the interior of an inaccessible line. Biological indicators complement physical process data; they do not replace a clear load description or assessment of measurement positions and treatment conditions.

Back to the term directory

Biomass

Related search terms: Cell mass

Biomass is the biological material formed by the cultivated organisms. Material balances often express it as dry mass per culture volume, for example grams per litre. Animal cell processes frequently use viable cell numbers per volume instead. These quantities are not interchangeable because cell size, water content, storage compounds and the fraction of dead cells can change.

Biomass may be the intended product, or it may provide the catalytic capacity to manufacture another substance. A high biomass concentration consequently does not guarantee a high product formation rate. Cells can divert nutrients into storage lipids or other reserves, increasing their mass more than their productive activity. Every reported biomass value needs an explicit measurement basis.

Used in these chapters · 45
Back to the term directory

Biomass-time integral

Related search terms: Biomass–time integral

Integral of biomass quantity present inside the boundary over a time window, such as ∫M_Xdt in g·h. It describes the biomass quantity available as a reference over time.

Total substrate consumption divided by this integral gives an average mass-specific uptake rate. Final biomass multiplied by duration is a different denominator in a growing culture. Account for withdrawals and the assumed interpolation between observations.

Used in these chapters · 2
Back to the term directory

Biomethane

Biomethane is methane-rich gas of biological origin obtained, for example, by upgrading biogas. Carbon dioxide and interfering constituents are reduced according to the intended application.

Biomethane does not denote a universal purity or automatic grid-entry permission. Composition, moisture and other quality requirements belong to the specific use. Methane losses during upgrading and supply are included in material and environmental balances.

Foundations: How Does Anaerobic Digestion Work?

Used in these chapters · 1
Back to the term directory

Bioreactor

Related search terms: Cultivation reactor

A bioreactor provides a technically controllable reaction environment for biological conversions. Living cells may grow and form products, while resting cells or isolated enzymes can also act as biocatalysts. The reactor must provide suitable conditions and match material and energy flows to biological activity. Relevant functions include nutrient provision, heat removal and the gas environment required by the particular process.

Biology therefore determines the equipment requirements: animal cells, rapidly growing bacteria and light-dependent algae have different needs. A vessel with an agitator and temperature control is not automatically suitable for production. Suitability depends on maintaining the required environment throughout the process while preserving the relevant function of the biocatalyst.

Used in these chapters · 51
Back to the term directory

Biot number

The Biot number Bi = hL_c/λ compares external heat transfer with conduction inside a body. Here h is heat-transfer coefficient, λ thermal conductivity and L_c a geometry-appropriate characteristic length.

It helps assess whether internal gradients may be neglected in a simplified thermal model. It is not a universal release criterion. Different length conventions or time-varying heat transfer must be considered explicitly in comparisons.

Foundations: 18.3 Transient Heat Transfer

Back to the term directory

Birnbaum–Saunders distribution

Related search terms: Fatigue life distribution

The Birnbaum–Saunders distribution is a continuous lifetime distribution with positive support in a common two-parameter form. Shape and scale determine its form; extended representations add a location parameter.

It is investigated as a possible model of fatigue-related failure times. For bioprocess equipment, failure mode, loading and right-censored units still functioning must be considered. The distribution’s name proves no fatigue mechanism and provides no maintenance interval on its own.

Foundations: Birnbaum-Saunders distribution

Back to the term directory

Blocking

Related search terms: Experimental block, Block effect

Blocking groups experimental units that share a known source of variation, such as measurement day or inoculum batch. Conditions to be compared are distributed within these blocks where possible.

This allows a treatment effect to be separated from a modelled block difference. If condition A occurs only on day one and B only on day two, condition and day are confounded. A block model cannot retrospectively supply the missing comparison.

Foundations: Randomized block designs

Used in these chapters · 12
Back to the term directory

Bond number

The Bond number Bo = ΔρgL²/σ compares gravity from a density difference with surface tension. Specify the selected length and both phases.

A vessel may exhibit gravity-dominated waves at its overall scale while small bubbles remain strongly affected by surface tension. Values based on different length scales are not interchangeable. At unchanged material properties, Bo grows with length squared: a tenfold reference length produces a hundredfold value. This geometrical effect explains why different influences can dominate at different scales. It does not replace assessment of motion, viscosity or interface behaviour in the actual process being considered.

Foundations: A simulation modeling framework for fluid motion and transport in a rocking bioreactor

Back to the term directory

Bottleneck

Related search terms: capacity bottleneck

A bottleneck is an effective constraint on the desired system outcome in the state considered. It may involve processing, utilities, staffing or a mandatory material condition. The longest single step is not automatically limiting when resources operate in parallel.

A targeted counterfactual changes the suspected constraint and checks system response. Another restriction may become limiting after improvement. Always describe a bottleneck alongside product mix, schedule and the specific performance question.

Foundations: Bioprocess Simulation, Economics and Design, lecture10 · Basic Concepts in Queueing, lecture8

Used in these chapters · 12
Back to the term directory

Bracketing

Bracketing examines justified boundary variants to support conclusions about variants within them. It requires those boundaries to represent the relevant challenge; ordering equipment by nominal volume is insufficient.

Geometry, air removal or load distribution can make an intermediate thermal variant more challenging. Document the inclusion rationale and reassess changes. Bracketing is not a universal substitute for necessary measurements.

Used in these chapters · 1
Back to the term directory

Break-even volume

Related search terms: break-even volume

Break-even volume covers fixed costs through unit contribution margin in the defined cost model. For one product, volume equals fixed costs/(price − variable unit cost), provided the denominator is positive.

For a bioprocess, the unit must represent saleable quality-conforming quantity when that generates revenue. A calculated result above technically available capacity exposes a contradiction in the business case. Multiple products require a justified sales mix.

Foundations: 3.2 Break-Even Point

Back to the term directory

Bubble-column bioreactor

A bubble-column bioreactor uses rising gas bubbles to circulate liquid and exchange material between the gas and liquid phases. Its basic design has no mechanically driven impeller and no deliberately separated riser and downcomer, unlike an airlift reactor. Buoyancy, bubble distribution and vessel geometry establish the circulation pattern.

Few moving internals simplify the culture chamber, but the resulting flow is not necessarily simple. Increasing gas loading can create clusters of bubbles and strongly fluctuating liquid motion. Doubling gas flow therefore does not guarantee twice the mass transfer. Comparisons between sizes require attention to column diameter, liquid height, broth properties and the bubble population that actually develops during operation.

Used in these chapters · 1
Back to the term directory

Bubble-point test

Related search terms: bubble point

In a bubble-point test, gas pressure above a fully wetted membrane is increased until liquid is displaced from its largest effective pores and gas flow rises sharply. The required pressure depends on surface tension, wetting and pore geometry, among other factors. Under comparable conditions, an unusually low value suggests larger passages or unsuitable wetting.

Interpretation therefore requires the specified wetting liquid, an appropriate temperature and filter-specific acceptance limits. Product residues can alter surface tension and invalidate comparison with a water-based test. The method is not a universal means of directly measuring every pore. It tests a physical property whose relationship with the intended microbial retention must have been established for the filter concerned.

Back to the term directory

Bubble-size distribution

The bubble-size distribution describes the bubble diameters present in an aerated liquid and their relative abundance. One average diameter can conceal very different populations. For mass transfer, the relationship between gas volume and interfacial area is particularly relevant, which is why the Sauter mean diameter is often used: it preserves the population’s volume-to-surface-area ratio.

Formation, break-up, coalescence and transport establish the distribution, which may vary across the vessel and over time. The mean near the sparger may therefore not represent the whole culture. Small bubbles provide more area at equal gas volume, but useful transfer also depends on residence, interfacial mobility and circulation. A single photograph is consequently not a complete characterisation of mass-transfer performance.

Back to the term directory

Buffer capacity

Buffer capacity describes how much strong acid or base is needed for a small pH change under specified conditions, often per solution volume. It depends on buffer inventory, current pH and active equilibria.

Solutions can have the same pH but respond differently to the same dose. CO₂-exchanging systems also require gas boundary and timescale: a closed titration does not automatically measure the buffering response of an aerated culture.

Foundations: 14.6 Buffers

Used in these chapters · 4
Back to the term directory

Buffer temperature coefficient

A buffer temperature coefficient describes change in a suitably defined buffer pH or pKₐ with temperature. Composition, pressure and gas boundaries must be specified.

Automatic temperature compensation of a pH instrument corrects electrical response; it does not remove the sample’s chemical temperature dependence. Reactor/offline comparisons therefore need actual sample temperature, with possible gas exchange additionally considered for CO₂-containing media.

Foundations: Evidence-based guidelines for controlling pH in mammalian live-cell culture systems · 14.6 Buffers

Back to the term directory

Business Impact Analysis (BIA)

Related search terms: BIA

A Business Impact Analysis examines how interruption of particular functions affects an organisation’s activities. It considers dependencies and consequences over time. It differs from a simple list of possible technical faults.

Loss of temperature control in a bioprocess facility can have different consequences from delayed report generation. The analysis helps prioritise recovery objectives and reserves according to actual effects. Without suitable data, it does not provide precise probabilities of future failures.

Foundations: Business Impact Analysis

Back to the term directory

C

Calibration

Calibration establishes the relationship between known reference values and indications from a measuring system under specified conditions. It includes uncertainty associated with both the reference and the measurement. This relationship is then used to establish how an indication translates into a measured value with associated uncertainty. For example, it can establish the readings and deviations obtained when a pH sensor measures defined buffer solutions.

In strict metrological usage, calibration does not automatically alter the instrument; subsequent adjustment is a separate operation. Practical records need reference material, temperature, measurement range and results. Passing a comparison at one point does not guarantee correctness across the full range or under process conditions. Reliable calibration before sterilisation also does not replace assessment of changes caused by sterilisation, ageing or deposits during use.

Used in these chapters · 36
Back to the term directory

Capacitance-based biomass measurement

Related search terms: dielectric spectroscopy, permittivity measurement

Capacitance-based biomass measurement exploits cellular polarisation in an alternating electric field. Intact membranes separate conductive regions and create a frequency-dependent contribution to suspension permittivity. This contribution can correlate with the volume of membrane-intact cells, allowing continuous estimation of viable biomass.

Conversion to cells per millilitre requires an appropriate reference and is not independent of cell size. Changes in diameter, membrane properties or culture phase can shift the relationship. The signal is therefore neither a universal direct cell count nor a complete demonstration of functional viability. In perfusion it is particularly useful for demand-based medium addition, provided that the correlation is verified across the relevant operating range.

Back to the term directory

Capacity headroom

Related search terms: capacity headroom

Capacity headroom here is the difference between available capacity and the demand under consideration, each under specified conditions. A percentage requires an explicitly stated denominator.

In a production campaign, free reactor hours can coexist with fully occupied purification equipment. Headroom therefore needs evaluation by resource and time. It is not an automatic promise of additional quality-conforming product output.

Foundations: Basic Concepts in Queueing, lecture8 · University Health Service process analysis, lecture10

Back to the term directory

Capital expenditure (CAPEX)

Related search terms: CAPEX, capital costs

CAPEX describes spending to acquire, build or substantially extend assets used over a longer period. Operational and accounting boundaries depend on context. Engineering estimates do not always use identical scope.

A bioreactor project may include installation, utilities and integration as well as equipment. A published factory investment is therefore not a reactor price. Comparisons need explicit boundaries and included services.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 2
Back to the term directory

Capital recovery factor

Related search terms: capital recovery factor

The capital recovery factor is the reciprocal of the annuity present value factor. It converts a present amount to n equal end-of-period payments at a specified constant rate. At i = 0 it is 1/n.

Equipment comparisons can use it to express investment as an annual model amount. Residual value, later investment and financing costs must not silently be omitted or counted twice. The conversion is a calculation convention, not an actual loan agreement.

Foundations: 11.3 Time Value of Money

Back to the term directory

Carbon dioxide equivalent

Related search terms: CO2-equivalent, CO₂-equivalent, CO2e

CO₂-equivalent expresses contributions from different greenhouse gases on a common basis using a stated assessment method. Quantities are combined with appropriate characterisation factors; time horizon and factor set belong to the result.

It is not identical to directly measured CO₂ mass in reactor exhaust. A product climate inventory may include other gases and life-cycle stages. It also does not automatically assess water scarcity, resource use or other environmental effects.

Foundations: Product Life Cycle Accounting and Reporting Standard

Used in these chapters · 1
Back to the term directory

Carbon dioxide evolution rate

Related search terms: CER, CO₂ evolution rate

Carbon dioxide evolution rate, CER, describes CO₂ formation or its release determined by a balance, per unit time. It is often normalised to culture volume and expressed in mmol/(L·h). Interpretation requires distinguishing biological production from the CO₂ currently leaving through the gas phase.

These quantities can differ during transitions because dissolved CO₂ and other inorganic-carbon species form a changing reservoir. Changes in pH and non-biological CO₂ input also need to be included in the balance. A sudden increase in exhaust CO₂ therefore does not alone demonstrate increased metabolic activity. Comparable CER values require an appropriate system boundary and treatment of input, output and accumulation terms, particularly during changing operating conditions.

Used in these chapters · 3
Back to the term directory

Carbon mole

Related search terms: C-mol

An amount-of-substance basis representing one mole of carbon atoms. One mole glucose contains six C-mol and one mole ethanol contains two. Different carbon-containing compounds can therefore share an elemental balance without equating their molecule amounts or masses.

Biomass is often represented by an empirical formula normalised to one carbon atom. Mass per C-mol depends on composition and material basis. A carbon mole is not a new substance and alone specifies neither degree of reduction nor available energy.

Used in these chapters · 3
Back to the term directory

Carbon recovery

Related search terms: Carbon closure

Fraction of the accounted carbon input recovered in recorded outputs and retained or newly accumulated inventories. The definition must state how initial inventory and unconsumed substrate enter numerator and denominator.

A value near 100% supports consistency of the selected balance but does not establish complete knowledge of metabolic pathways. Higher or lower values call for checks of boundary, composition and uncertainty. A residual does not automatically identify an unknown product.

Used in these chapters · 1
Back to the term directory

Carbon source

Related search terms: Carbon substrate

A carbon source supplies carbon atoms for cellular material and, where applicable, the desired product. Heterotrophic cultures use organic compounds such as sugars, whereas autotrophic cultures obtain carbon mainly from inorganic compounds. Carbon source and energy source are consequently not always the same: a photoautotrophic alga uses inorganic carbon but obtains energy from light.

The chosen source influences metabolic pathways, reducing equivalents and by-products. Its presence does not establish that the particular strain can consume it. High total carbon content also reveals little about the usable fraction. Comparing substrates requires consideration of their chemical composition, not just their mass, and of the fractions ultimately directed towards biomass, product or carbon dioxide.

Used in these chapters · 9
Back to the term directory

Cascade control

In classical cascade control, an outer controller sets the target for a faster inner control loop. A culture-temperature controller may, for example, specify the jacket temperature, which is then controlled separately. Disturbances in the inner loop can thus be corrected before fully affecting the primary variable.

Bioprocess practice also uses the term DO cascade for staged activation of agitation, gas flow and oxygen enrichment. Sequential use of actuators is not automatically the same structure as two nested feedback loops. Reliable design requires knowledge of actuator sequence, limits and actual feedback paths. An inner loop that is too slow or conflicting actuator ranges can remove the expected benefit and introduce oscillation.

Used in these chapters · 2
Back to the term directory

Catabolite repression

Related search terms: Carbon catabolite repression, CCR

Catabolite repression is regulation through which an easily utilised nutrient source can reduce the cellular machinery for using other substrates. Cells thereby allocate limited resources to pathways that are advantageous under current conditions. The signals and regulators differ between organisms; the term does not describe one identical molecular switch everywhere.

This matters in production when the desired pathway becomes strongly active only under particular nutrient conditions. Abundant glucose may, for example, promote growth while reducing the formation of an enzyme needed for production. A substrate change can consequently cause an adaptation period. The presence of several usable carbon sources does not establish that all will be consumed equally quickly or simultaneously.

Back to the term directory

Cauchy distribution

The Cauchy distribution is a symmetric continuous distribution with location and positive scale parameters and heavy tails. Its expectation and variance are undefined, although its median and location parameter exist.

It illustrates why symmetry alone does not justify ordinary mean or variance interpretation. For extremely variable data, errors, mixed populations and a suitable distributional form must first be distinguished. Replacing a normal distribution with Cauchy is not an automatic solution to unexplained outliers.

Foundations: Cauchy distribution

Back to the term directory

Cell bleed

A cell bleed is a deliberate withdrawal of cell-containing culture from a process that uses cell retention. Whereas a largely cell-free perfusion outlet mainly removes medium and transmissible products, the bleed directly reduces the number of cells remaining in the system. Withdrawal may be continuous or performed in defined steps.

Bleeding helps maintain a target cell density and prevents excessive demands on oxygen supply or nutrients. It also removes medium, product and productive cells. Reliable balances therefore record bleed separately from the product stream and analytical samples. A falling cell concentration can only be interpreted correctly when actual cell withdrawal, growth and cell death are considered together.

Used in these chapters · 3
Back to the term directory

Cell counting

Related search terms: total cell concentration

Cell counting determines how many cells are present in a defined sample. The count, examined volume and dilution factor give a cell concentration, commonly in cells/mL. Haemocytometers, imaging instruments and other suitable single-cell methods can be used; each needs explicit rules for distinguishing cells, aggregates and particles.

Total cell concentration differs from viable cell concentration. They serve different purposes in growth assessment, inoculation and perfusion control. Counting small numbers creates statistical variability, while clumps and sedimentation can introduce systematic bias. Automation does not inherently remove these problems. Comparability requires documented sample handling, dilution, detection thresholds and aggregate treatment appropriate to the particular cell type.

Used in these chapters · 20
Back to the term directory

Cell disruption

Related search terms: Cell lysis

Opening or breaking cells to make intracellular components accessible, using mechanical, chemical or enzymatic effects depending on the method. Disruption differs from merely separating intact cells from medium.

It releases other cellular constituents alongside the desired product. Extent of disruption, product function and subsequent separability are therefore separate questions. More released total protein does not automatically mean more intact target product; method choice depends on material and purpose.

Foundations: Recovering plasmid DNA from bacterial culture

Used in these chapters · 6
Back to the term directory

Cell lifeline

Related search terms: lifeline, cell trajectory

A cell lifeline describes the temporal sequence of environmental conditions along a cell representative’s path, for example substrate, oxygen or pH.

A computed lifeline is not an observed biological response. Interpretation needs appropriate experiments or a justified response model with stated limitations. Analysis records the sampling grid, path identifier, variables and assumptions governing movement. Equal mean concentrations or zone time fractions do not establish the ordering and duration of individual episodes. Those features, together with coincident conditions, may be critical when formulating a hypothesis about biological response.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Used in these chapters · 3
Back to the term directory

Cell line

Related search terms: Production cell line

A cell line is a population maintained through continued culture with a traceable derivation. It may have a finite capacity to proliferate or may be a continuous line capable of prolonged cultivation. A cell line is not automatically a clone: derivation from one starting cell requires its own supporting evidence. Even populations of clonal origin can change over time.

In production, growth, product formation and relevant cellular characteristics matter more than the name alone. Medium changes and repeated passages can favour different subpopulations and alter culture behaviour. Statements about suitability should therefore identify the bank, its history and the cultivation range examined. Indefinite proliferative capacity does not mean indefinite functional consistency.

Used in these chapters · 15
Back to the term directory

Cell retention

Cell retention separates cells from outgoing culture medium and keeps them in, or returns them to, the reactor. Membranes, sedimentation and acoustic methods are possible mechanisms. In tangential flow filtration (TFF), liquid flows along a membrane; alternating tangential flow (ATF) uses a reversing flow direction.

Retention decouples cellular residence from medium exchange and is central to many perfusion processes. Its efficiency is not an immutable property of the culture mode: cell size, aggregation, membrane deposits and operating conditions affect cell loss. Product transmission also requires evaluation. Strong cell retention combined with poor product passage can raise the measured reactor titre without producing a corresponding increase in recoverable yield.

Used in these chapters · 16
Back to the term directory

Cell-specific perfusion rate

Related search terms: CSPR

Cell-specific perfusion rate, or CSPR, expresses the medium volume supplied per viable cell per day. With medium flow F, culture volume V and viable cell concentration Xᵥ, CSPR = F/(VXᵥ). A common unit is pL/(cell·day); all quantities must use compatible units before calculation.

CSPR connects medium consumption with the population that requires support. As viable cell density rises, medium flow must increase to maintain a constant CSPR. The suitable value depends on medium composition, cell line and metabolic state, however; it is not a universal minimum allowance. Errors in viability or cell counting directly affect the calculated supply and may misdirect an automated feeding strategy.

Used in these chapters · 4
Back to the term directory

Cellular respiration

Related search terms: Respiratory metabolism

Cellular respiration transfers electrons through a membrane-associated transport chain to a terminal electron acceptor. The resulting electrochemical gradient can drive ATP synthesis. Oxygen serves as the terminal acceptor in aerobic respiration, while some microorganisms use other compounds instead. Respiration and oxygen consumption are therefore not identical concepts in every biological context.

In aerobic bioprocesses, this pathway connects nutrient conversion, gas demand and heat generation. The ATP obtained per substrate nevertheless depends on the organism and coupling state rather than being a universal constant. Respiring cells can also release by-products simultaneously. Adequate oxygen therefore guarantees neither complete substrate oxidation nor maximum biomass yield; regulation of the wider metabolic network remains important.

Used in these chapters · 2
Back to the term directory

Censoring

Related search terms: Right censoring, Right-censored

Censoring means a quantity is not observed exactly but a bound or interval for its value is known. For a right-censored lifetime, for example, a component is known still to function at the end of observation.

This observation is neither treated as a failure at the endpoint nor simply discarded. Either approach can distort lifetime assessment. Analysis and model must account for the censoring mechanism; different failure modes may require separate consideration.

Foundations: Censoring

Back to the term directory

Central composite design

Related search terms: CCD

A central composite design combines a factorial core with axial points and centre runs. It can thereby support estimation of a quadratic response-surface model.

Axial-point placement determines whether points lie inside, on or outside the factorial-level cube. A face-centred design is not generally rotatable. Required settings, replication and estimability must be checked against the specific process limits before use.

Foundations: Central Composite Designs

Used in these chapters · 1
Back to the term directory

Centrifugation

A separation method in which rotation accelerates movement of particles or phases with different sedimentation behaviour. For cells in liquid, size, density difference, shape and liquid properties affect separation.

Rotational speed alone does not specify acceleration because radius also matters. Time, rotor or equipment geometry and material state are relevant to comparison. High separation efficiency does not guarantee unchanged viability or product function.

Foundations: Absolute bacterial cell enumeration using flow cytometry

Used in these chapters · 3
Back to the term directory

Certificate of analysis

Related search terms: CoA, analysis certificate

A certificate of analysis connects an identified material lot to examined characteristics, methods or specifications and results. Its value depends on correspondence with the supplied lot and intended use.

It is not a general suitability certificate for every bioprocess. For medium ingredients, examine chemical form, assay basis, relevant impurities and traceable lot identity. Changing supplier may require additional comparison data despite similarly worded certificates.

Foundations: 11965 – DMEM, high glucose: formulation

Used in these chapters · 1
Back to the term directory

Certificate Revocation List (CRL)

Related search terms: CRL

A Certificate Revocation List identifies certificates revoked before their planned expiry. It is digitally signed and needs consideration within the relevant trust procedure. Expiry and revocation are different reasons for no longer accepting a certificate.

When service access to a bioreactor platform ends, knowing an old expiry date may be insufficient. Responsible personnel need to understand the mechanism used for withdrawal and checking. An outdated or unevaluated list does not provide effective revocation checking.

Foundations: Certificate Revocation List

Back to the term directory

Change control

Related search terms: controlled change

Change control assesses proposed modifications for their effect on the established suitability of a system or process. Examples include new seals, a changed sterilisation recipe, a different supplier or additional connections. Affected requirements, risks and existing evidence are considered before implementation, leading to necessary actions and, where appropriate, further testing.

An apparently small change can be functionally important: a longer tube may alter air removal or drainage. Conversely, not every identical replacement component requires complete requalification. The decision needs justification. Pharmaceutical quality systems address this formally, while a traceable change record is also useful in research laboratories. It prevents later results from being explained using evidence obtained for an earlier configuration that no longer exists unchanged.

Used in these chapters · 2
Back to the term directory

Charge equivalent

Related search terms: Equivalent concentration, meq

A charge equivalent relates amount of substance to a specified number of elementary charges or the proton or electron balance of a defined reaction. One mole of monovalent charge is one mole of charge equivalent.

In conventional alkalinity reporting, one mmol equivalent corresponds to 50 mg as CaCO₃. The appropriate equivalent mass depends on the substance and reaction; molar mass alone is insufficient. Reaction basis and unit prevent confusion between mg L⁻¹ expressed as different chemical reference substances.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Chelation

Related search terms: chelator

Chelation is complex formation in which a ligand coordinates through multiple binding sites to the same central entity, forming at least one ring. It is a specific form of coordination.

A chelator can change free metal-ion concentration without removing total metal. Media assessment must consider supply, competing ions and ligand amount together. Chelator presence establishes neither complete binding nor absence of biological availability.

Foundations: 19.2 Coordination Chemistry of Transition Metals

Back to the term directory

Chemical activity

Related search terms: species activity

Chemical activity is a thermodynamic quantity describing effective composition relative to a selected standard state. A concentration convention can write aᵢ = γᵢcᵢ/c°. Activity is dimensionless, with the activity coefficient representing departure from the chosen ideal reference.

Equilibrium constants require consistent activities. Analytical total concentrations cannot automatically replace free-species activities, especially in pH and precipitation calculations. The standard concentration and the coefficient convention must also agree; values tabulated under different conventions cannot be combined arbitrarily.

Foundations: 11.4 Colligative Properties · 15.1 Precipitation and Dissolution · Quantities, Units and Symbols in Physical Chemistry (IUPAC Green Book)

Back to the term directory

Chemical indicator

Related search terms: process indicator

A chemical indicator uses an observable chemical or physical change to show that particular treatment conditions have acted upon it. A colour change may indicate exposure to a process, while other designs respond to several selected variables. The meaning depends on the specific indicator type and its stated performance characteristics.

Changed autoclave tape on a package does not prove that the entire contents are sterile. It can nevertheless help distinguish treated from untreated items. For more demanding assessments, the indicator must match the question and its placement. Expired materials, incorrect storage and inappropriate interpretation limit the result. Evaluation is combined with relevant process records and does not replace a justified sterilisation validation programme.

Used in these chapters · 1
Back to the term directory

Chemical oxygen demand

Related search terms: COD

Chemical oxygen demand is a method-dependent aggregate measure of oxidisable constituents expressed as an oxygen equivalent. Wastewater balances commonly use mg O₂ L⁻¹ or the corresponding load.

COD is neither direct carbon mass nor automatically fully biologically available. Dissolved and particulate fractions and analytical interferences affect interpretation. Oxygen-demand calculations consistently account for remaining COD, biomass export and anoxic electron acceptors.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Chemical speciation

Related search terms: speciation

Speciation describes the chemical forms of a component and how its total inventory is distributed between them. Free ions, protonated forms, complexes and possible solids must be distinguished.

Total calcium is not a direct measurement of free Ca²⁺. A medium balance may close an elemental inventory without knowing all species fractions. A speciation model needs appropriate equilibria, state conditions and phase boundaries.

Foundations: 15.1 Precipitation and Dissolution · 15.2 Lewis Acids and Bases

Used in these chapters · 3
Back to the term directory

Chemically defined medium

Related search terms: Defined medium, CD medium

A chemically defined medium has known chemical components added in known amounts. Unresolved mixtures such as an undefined yeast extract therefore do not belong in this category. Defined composition supports targeted nutrient balances and investigation of individual component effects. It does not automatically describe a minimal or particularly simple formulation.

A defined medium may contain many components and be tailored to one cell line. The term also differs from serum-free and animal-origin-free, which address different attributes. Defined does not mean chemically unchanged throughout cultivation either: degradation, precipitation and cellular conversion can alter the composition actually present. The formulation is a controlled starting point, rather than a guarantee of constant nutrient availability.

Used in these chapters · 2
Back to the term directory

Chemometrics

Related search terms: multivariate data analysis

Chemometrics uses mathematical and statistical methods to organise chemical measurement data and extract relevant information. In process analysis, many spectral channels may be evaluated together to predict concentrations or recognise unusual conditions. Principal component analysis and partial least squares regression, for example, serve different purposes.

The result depends strongly on reference data, sample diversity and proper separation of model development from independent evaluation. Placing near-identical time points from one batch in both datasets can make predictive performance appear unduly favourable. High correlation also does not demonstrate selectivity against changed media or unfamiliar disturbances. Sound models need a stated applicability domain, traceable preprocessing and monitoring of performance during subsequent use.

Back to the term directory

Chemostat

A chemostat is a continuous culture in which a deliberately limiting nutrient and a prescribed medium throughput govern growth. Fresh medium enters and well-mixed culture broth leaves at equal volumetric rates. Without cell retention, new biomass must replace the cells lost through the outlet.

At an ideal steady state with negligible cell death, μ = D: specific growth rate μ equals dilution rate D, both expressed in h⁻¹. This enables experiments at defined growth rates. Constant biomass concentration does not demonstrate genetic stability, however. Wall growth, contamination, additional limitations or excessive throughput can invalidate the simple model and require separate monitoring during extended experiments.

Used in these chapters · 5
Back to the term directory

Chi-square distribution

Related search terms: Chi-squared distribution

A chi-square distribution with integer degrees of freedom ν arises from the sum of squares of ν independent standard normal variables. Its mean is ν and variance is 2ν.

It provides a reference for appropriate variance and goodness-of-fit questions. Not every sum of squared process deviations automatically follows it: scaling, independence and estimated parameters matter. The degrees of freedom used are derived from the specific model.

Foundations: Chi-square distribution

Back to the term directory

Chinese hamster ovary cells (CHO)

Related search terms: CHO cells, CHO

CHO cells are cell lines derived from Chinese hamster ovary tissue. They are an established host platform for recombinant proteins, particularly antibodies. As mammalian cells, they can fold, secrete and glycosylate proteins, although this does not automatically reproduce every feature of a human protein made in its natural tissue.

CHO denotes a family of different lines and production clones. Medium requirements, metabolism and productivity can differ substantially between them. Even an established clone responds to culture conditions, potentially changing lactate formation or product attributes. Process development must therefore consider growth and product quality together. A high final titre alone demonstrates neither the intended molecular characteristics of the product nor a consistently reproducible manufacturing process.

Used in these chapters · 6
Back to the term directory

Chlorophyll

Related search terms: Chlorophylls

Chlorophylls are a family of light-absorbing pigments with a magnesium-containing ring system that play a central role in photosynthetic organisms. Different chlorophyll types and molecular environments have different absorption spectra.

A chlorophyll value does not automatically describe total biomass or product formation. Photoacclimation can change pigment fraction. Measurement must therefore state chlorophyll type, extraction method and reporting basis; stronger colour alone is not evidence of greater growth.

Foundations: Biology 2e: Light-dependent reactions of photosynthesis · Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 1
Back to the term directory

Chromatin

Chromatin is the complex of DNA and associated proteins in the eukaryotic nucleus. It organises DNA spatially and influences its accessibility for cellular use. Chromatin is therefore more than passive packaging: an unchanged DNA sequence can exist in different organisational states.

This matters when evaluating production-cell-line stability. An unchanged sequence does not establish unchanged expression. To explain a sustained change in product formation, genetic findings and evidence about expression state must be assessed separately. A chromatin mechanism remains a hypothesis until supported by appropriate measurements.

Foundations: NHGRI: Chromatin

Back to the term directory

Chromatographic breakthrough

Related search terms: breakthrough, breakthrough curve

Breakthrough is the appearance or increase of a substance at the outlet during loading. A criterion may specify an outlet-to-inlet concentration ratio. Measurement position and timing must be known.

Ten per cent instantaneous breakthrough is not ten per cent cumulative product loss. Lost mass requires integration of actual outlet mass flow. Mobile inventories and transport volumes may also matter when determining binding capacity.

Foundations: CaptivA HF Protein A Affinity Resin

Used in these chapters · 2
Back to the term directory

Chromatography

Related search terms: chromatographic

Chromatography separates components through different interactions with stationary and mobile phases. Methods may differ in binding, partitioning or access to pore spaces; they do not all rely on the same molecular property.

Recovery-process evaluation considers capacity, selectivity, recovery and full occupancy together. An analytical separation signal and preparative process performance are different tasks. Select the step according to the target and impurities actually requiring removal.

Foundations: Protein preparation handbook

Used in these chapters · 8
Back to the term directory

Chromatography regeneration

Related search terms: resin regeneration

Chromatography regeneration is a treatment that restores a stationary phase to a suitable condition for reuse. Conceptually it differs from product elution, cleaning and subsequent equilibration, even when a procedure combines steps.

Resin reusability is assessed through appropriate performance and quality evidence. A nominal cycle count does not replace that evidence. Campaign models must also include the time and consumables needed for each planned regeneration.

Foundations: CaptivA HF Protein A Affinity Resin · Protein preparation handbook

Back to the term directory

Chromatography resin

Related search terms: resin

Chromatography resin is an engineered stationary separation medium, often porous particles with suitable surface groups or ligands. The name describes its technical function rather than necessarily the same chemical class as an everyday synthetic resin.

Particle and pore properties, ligand and packing state affect performance and hydraulics. Define resin volume as the actual packed or otherwise specified reference volume. Compare supplier capacity and service life only under their corresponding conditions.

Foundations: CaptivA HF Protein A Affinity Resin · Protein preparation handbook

Used in these chapters · 3
Back to the term directory

Circularity

A common circularity measure is 4πA/P², using projected area A and perimeter P. An ideal circle has value one in consistent continuous geometry.

Digital resolution and perimeter estimation affect the result. Circularity is neither sphericity nor direct evidence of compact or living biomass. A common definition is 4πA/P² using area A and perimeter P; an ideal circle has a value of one. Pixel resolution, smoothing and segmentation boundaries particularly affect perimeter. Comparisons therefore require the same definition and an assessment of sensitivity to the image-analysis procedure used.

Used in these chapters · 1
Back to the term directory

Citric acid cycle

Related search terms: TCA cycle, Krebs cycle

The citric acid cycle is a central metabolic pathway that converts acetyl groups and generates reducing equivalents and carbon dioxide. It also supplies intermediates for the construction of important cellular components. Most of its reactions occur in mitochondria in eukaryotic cells, whereas bacteria perform corresponding reactions without that organelle. The organisation and use of the pathway differ among organisms.

When intermediates are withdrawn for biosynthesis, replenishing reactions must restore the pool. The cycle is therefore linked to growth and product formation rather than operating as an isolated combustion unit. Its activity cannot be inferred from carbon dioxide release alone because other pathways also generate or consume carbon dioxide. Quantitative interpretation requires a broader metabolic balance.

Back to the term directory

Clarification

Related search terms: clarification step

Clarification removes selected suspended material from a liquid, such as cells or debris from harvest. Centrifugation and suitable filtration are possible methods. The following process duty determines which particles require removal.

An optically clear liquid is not automatically sterile or free of dissolved impurities. Sizing considers particle separation, product loss, processing time and downstream burden together. Effective clarification alone does not establish complete product purification.

Foundations: Biochemical Processing: Overview, lecture2

Used in these chapters · 9
Back to the term directory

Cleaning

Related search terms: equipment cleaning

Cleaning removes unwanted residues from a surface. These may include culture deposits, proteins, fats, salts and processing aids. Its effectiveness depends on the combined action of chemistry, temperature, mechanical input and time. The appropriate combination is influenced by the type of soil, whether it has dried and how readily the surface can be reached.

Cleaning does not automatically disinfect or sterilise equipment. It often establishes the conditions needed for a subsequent treatment to contact the surface effectively. A reactor that looks clean can still contain invisible residues, so the cleaning objective and suitable assessment should be defined beforehand. Excessively harsh conditions may damage materials or seals and create new contamination sites. Rinsing must also remove the cleaning agents themselves sufficiently.

Used in these chapters · 34
Back to the term directory

Cleaning in place (CIP)

Related search terms: in-place cleaning

Cleaning in place cleans the product-contact internal surfaces of equipment without dismantling the principal components intended for that procedure. Cleaning liquid circulates through pipework or reaches vessel surfaces through suitable distribution devices. A defined sequence may combine pre-rinsing, chemical cleaning and final rinsing. Connections, valve seats and areas behind internal fittings must also receive effective treatment.

CIP describes how cleaning is performed, not automatically how well it works. High flow in a main pipe says little about a poorly swept branch. The recipe, soil and equipment geometry must be compatible. Measurements such as conductivity can monitor execution but do not replace justified evidence of residue removal. Subsequent sterilisation remains a separate task with different effectiveness criteria.

Used in these chapters · 3
Back to the term directory

Cleaning out of place (COP)

Related search terms: off-line cleaning

Cleaning out of place means cleaning components away from their operating position after removal. Examples include detached lids, gaskets and small fittings cleaned in a suitable bath, parts washer or defined manual procedure. Dismantling makes surfaces accessible that cannot be reached adequately when the equipment is assembled.

Improved access introduces additional needs for identification, protection and correct reassembly. Mixed-up components, damaged gaskets or unprotected storage can negate the benefit of cleaning. COP is neither inherently worse nor inherently better than CIP; the achievable cleaning effectiveness and reliable handling determine suitability. Where manual steps are involved, their important conditions should be sufficiently clear for different operators to achieve comparable results. Any required sterilisation must be addressed separately.

Back to the term directory

Cleaning validation

Related search terms: validation of cleaning

Cleaning validation documents that a defined cleaning procedure reproducibly reduces relevant residues below justified acceptance limits. It considers soil, surfaces, cleaning conditions and permitted holding times. A difficult location or particularly persistent residue may be more decisive for the study than an average challenge.

Suitable investigations combine representative sampling locations with a sufficiently sensitive method and assessed recovery. A negative result has little meaning if the sampling procedure scarcely recovers the target substance from the surface. In pharmaceutical use, limits require scientific justification; an arbitrary universal limit does not suit every product. Cleaning validation must also be distinguished from ongoing verification of individual cleaning operations. Changes to the product, recipe or equipment can limit the applicability of existing evidence.

Back to the term directory

Cleaning-agent residues

Related search terms: detergent residues

Cleaning-agent residues are constituents of cleaning chemicals or their reaction products that remain after cleaning. They may adhere to surfaces or remain dissolved in retained liquid. In the next bioprocess, possible effects include altered pH, cell inhibition and unwanted interactions with the product. Effective removal of the cleaning chemistry is therefore part of the cleaning objective.

Clear rinse water is insufficient evidence because many dissolved residues are invisible. Conductivity can detect certain ionic substances but is not equally sensitive to every compound. The selected assessment must match the chemistry and acceptable limit. Rinse samples also do not necessarily represent inaccessible surfaces completely. Residual quantity, potential biological or chemical effect and the subsequent process together determine the necessary assurance.

Used in these chapters · 1
Back to the term directory

Cloning vector

DNA carrier used to receive and propagate a chosen DNA segment. Suitability depends on the particular construct and host.

Successful propagation of a cloning vector does not automatically make it a suitable expression system. Required product-related regulatory elements must also be present and functional.

Foundations: Addgene

Back to the term directory

Coalescence

Coalescence is the merging of two or more gas bubbles into a larger bubble. After bubbles approach, the liquid film between their interfaces must drain or change sufficiently for their gas volumes to join. A collision therefore does not necessarily result in coalescence. Surface-active substances and liquid properties strongly affect the probability of merging.

For an equal gas volume, one large bubble has less surface area than several smaller bubbles. Coalescence can consequently reduce available exchange area while changing rise behaviour and gas distribution. It competes with bubble break-up within a reactor, and both processes shape the observed population. A bubble pattern established in water is therefore not directly transferable to a protein-rich or otherwise surface-active broth.

Used in these chapters · 3
Back to the term directory

Codon

A codon is a three-base unit interpreted in a defined reading frame to specify an amino acid or a termination signal during translation. The standard code contains 64 triplets, including three stop signals. That standard does not apply without qualification to every organism and cellular compartment.

A production sequence therefore needs a compatible host, genetic code and reading frame. Different codons can specify the same amino acid, so a DNA change need not alter the protein sequence. Whether that change affects expression is a separate experimental question rather than an automatic consequence of its sequence description.

Foundations: NHGRI: Codon

Back to the term directory

Coefficient of determination

Related search terms: R², R2

The coefficient of determination R² commonly compares residual sum of squares with total sum of squares around the observed mean: R² = 1 − SSE/SST. The definition used and assessed dataset belong with the result.

A high value on fitting data does not demonstrate good prediction of new runs. For external predictions R² can be negative; with constant reference values this ratio is undefined. Additional model terms are therefore not adopted solely because R² increases.

Foundations: Metrics and scoring: quantifying prediction quality

Used in these chapters · 7
Back to the term directory

Coefficient of performance (COP)

Related search terms: COP

COP relates defined useful heating or cooling duty to driving power. For refrigeration it may mean removed heat divided by electrical input. State the precise system boundary.

A COP of four then means four units of cooling per unit of input energy. Pumps and auxiliaries are included only if the definition contains them. COP is not a universal constant independent of temperatures and load.

Foundations: 4.3 Refrigerators and Heat Pumps

Used in these chapters · 3
Back to the term directory

Coefficient of variation

Related search terms: CV

The coefficient of variation is standard deviation divided by the corresponding mean. It is dimensionless or expressed as a percentage and describes relative variation on a scientifically meaningful ratio scale.

It becomes unstable near a zero mean; interpretation is problematic for quantities with an arbitrary zero point. Light maps specify whether the spatial population or a sample is assessed and how area weighting is applied. A small CV alone does not establish biologically suitable light intensity.

Used in these chapters · 1
Back to the term directory

Cold spot

Related search terms: slowest-to-heat location

A cold spot is a location that experiences a particularly unfavourable temperature or the lowest relevant thermal effect during a treatment. It need not remain at the same geometrical position throughout the cycle. Heating behaviour and circulation can matter in liquids, while mass, shielding and contact conditions influence components.

For sterilisation assessment, the position with the lowest accumulated lethality is often more important than the lowest isolated temperature reading. Cold spots are therefore investigated under representative loading conditions. A conveniently installed control sensor is not automatically a cold-spot sensor. Changes in fill volume, internal fittings or loading can shift the least favourable location. Monitoring must maintain a defensible relationship with that changing physical challenge.

Used in these chapters · 2
Back to the term directory

Colligative property

Related search terms: colligative properties

A colligative property of a dilute ideal solution depends on the number of dissolved particles relative to solvent. Examples include freezing-point depression and osmotic pressure. A dissolved salt can produce several ions per formula unit; weighed mass alone therefore does not measure particle number.

Media assessment must distinguish an ideal calculation from measured behaviour. Ionic interactions and incomplete dissociation can modify the predicted contribution. Two solutions with the same measured osmolality need not have the same ionic composition or effect across a cell membrane.

Foundations: 11.4 Colligative Properties

Used in these chapters · 1
Back to the term directory

Commissioning

Related search terms: commissioning

Commissioning comprises planned technical activities that bring installed equipment into a functional operating state. Scope and completion criteria are defined for the system. It can contain testing but is not automatically equivalent to complete process validation.

Bioreactor commissioning involves connections, functions, settings and operational handover. Successfully powering equipment does not establish a suitable biological process. Describe transitions to acceptance, qualification and routine use explicitly.

Used in these chapters · 6
Back to the term directory

Compartment model

Related search terms: zone model

A compartment model divides a system into simplified regions with separate inventories and defined exchange flows. Ideal mixing is often assumed within each region.

Summed regional balances must reproduce the overall balance. Additional regions improve prediction only when they represent relevant distinctions supported by sufficient information. Each exchange appears as a departure from one zone and an arrival in another carrying the same material amount. This structure preserves internal conservation but does not establish spatial adequacy: a network may conserve total inventory exactly while failing to resolve brief local concentration extremes.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 3
Back to the term directory

Complex medium

Related search terms: Undefined medium

A complex medium contains at least one ingredient whose individual chemical components are not fully specified, such as peptone or yeast extract. These mixtures can supply amino acids, peptides, vitamins and other growth-supporting compounds simultaneously. They often support organisms with demanding or incompletely understood nutritional requirements. Complex refers to compositional definition rather than simply the number of ingredients.

Biological origin can introduce differences between ingredient lots. Adding the same nominal amount therefore does not guarantee identical provision of every active component. Recording the raw material lot and relevant quality attributes helps interpret process comparisons. Strong growth alone also does not identify which nutrient caused the observed advantage or show that the same advantage will extend to product formation.

Used in these chapters · 2
Back to the term directory

Complex viscosity

Complex viscosity describes frequency-dependent viscoelastic response in oscillatory shear. Its magnitude satisfies |η*| = |G*|/ω, with angular frequency ω, and has units Pa·s.

It does not automatically equal steady viscosity at a numerically equal shear rate. Any such equivalence needs empirical assessment for the material. Its magnitude uses |G*| = √(G′² + G″²). Substituting frequency in Hz for angular frequency without the factor 2π introduces a systematic conversion error. Frequency, temperature and amplitude therefore accompany a reproducible comparison, together with the sign convention if complex components rather than magnitude are reported.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

Complexation

Related search terms: complex formation

Complexation associates a central entity, often a metal ion, with ligands through coordination. The free-ion fraction can change without removal of the total elemental inventory from solution.

In a medium, total added metal must therefore be distinguished from biologically or analytically relevant free species. Amino acids or other ligands may influence a simple salt comparison. A suitable model needs the actual binding partners.

Foundations: 15.2 Lewis Acids and Bases

Used in these chapters · 2
Back to the term directory

Compound Annual Growth Rate (CAGR)

Related search terms: CAGR

CAGR is the constant calculated annual rate connecting a positive starting value to a positive ending value over n years: CAGR = (ending value/starting value)^(1/n) − 1. It smooths change between two points rather than describing the observed growth rate in every intervening year.

For bioreactor markets, interpretation depends on market definition, currency, price basis and period. Forecast CAGR remains a model assumption. Growth of medicine revenues cannot be treated as equal growth of equipment sales without further assumptions.

Used in these chapters · 3
Back to the term directory

Compressibility factor

Compressibility factor Z describes departure of a real gas from ideal behaviour through pV = ZnRT. An ideal gas has Z equal to one.

Temperature, absolute pressure and composition determine an appropriate value. Correcting for Z does not repair a flow value with an unspecified reference state or wet/dry basis. Converting the same molar flow between two states includes Z₂/Z₁ as well as temperature and pressure ratios. The factor is dimensionless. It should not be confused with the mechanical compressibility of liquids or an arbitrary instrument correction; its thermodynamic definition determines how it enters the calculation.

Back to the term directory

Computational fluid dynamics

Related search terms: CFD

Computational fluid dynamics, CFD, approximates flow fields within a spatially divided model domain. It solves conservation relationships for mass and momentum and, where relevant, energy and chemical species. In bioreactors, it can investigate circulation paths, local concentration differences and regions of intense mechanical exposure that are difficult to observe comprehensively in experiments.

Results depend on geometry, boundary conditions, material properties, mesh resolution and models for turbulence or multiphase flow. An attractive colour map therefore does not establish accuracy. Useful checks include conservation balances, sensitivity to spatial resolution and comparison with appropriate measurements. Biological conclusions additionally require defensible descriptions of consumption and cell responses, rather than relying on hydrodynamic outputs alone.

Used in these chapters · 4
Back to the term directory

Concentration gradient

A concentration gradient describes a spatial change in the concentration of a substance. It can arise in a bioreactor when local addition or consumption acts faster than transport can equalise the resulting difference. A feed location may then experience a temporarily high concentration while another region is poorly supplied, despite an apparently acceptable average.

Cells experience the environments they actually pass through. The magnitude, duration and repetition of differences may therefore matter more than one maximum or minimum value. A spatial gradient must also be distinguished from a time-dependent change occurring everywhere together. Scale transfer should assess the differences generated by geometry and demand, and whether a small experimental system represents the relevant exposure.

Used in these chapters · 1
Back to the term directory

Concentration polarisation

Related search terms: concentration polarization

Concentration polarisation is local enrichment or depletion near a membrane when transport towards the surface, passage and back-transport create different local states. Surface concentration can therefore differ from well-mixed bulk concentration.

It can affect observed passage and required pressure. Changes in flow or flux may alter the condition where the actual experiment permits. Concentration polarisation does not automatically mean permanent chemical or mechanical membrane damage.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems · Dialysis Methods for Protein Research

Used in these chapters · 3
Back to the term directory

Condensate

Related search terms: steam condensate

Condensate forms when steam changes into liquid and releases heat. This heat transfer is essential to many steam sterilisation processes. The resulting water must nevertheless be directed so that it does not create unfavourable accumulation, obstruct steam paths or flow backwards where it is unwanted. Slopes, drains and suitable steam traps therefore form part of the functional assessment.

The presence of condensate is not inherently a fault; without condensation an important heat-transfer mechanism would be absent. Uncontrolled accumulation and poorly monitored locations are the problem. Condensate can also carry substances from steam generation or distribution. Its chemical quality and its behaviour during the cycle are different questions. A hot drain alone demonstrates neither adequate steam quality nor treatment of every connected surface.

Used in these chapters · 21
Back to the term directory

Condensate subcooling

Related search terms: subcooled condensate, subcooling

Subcooled condensate is at a temperature below the boiling temperature of water at the local pressure. At that pressure it has lower specific enthalpy than saturated condensate. Heat delivered by a steam stream therefore also depends on the state in which condensate leaves the selected system boundary.

A low condensate temperature may inform an energy balance but does not prove adequate treatment of a neighbouring surface. Pressure, measurement location and actual contact remain relevant. Subcooling below the local saturation temperature here must not be confused with supercooled liquid water below its freezing point.

Foundations: Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam

Used in these chapters · 2
Back to the term directory

Confidence interval

A confidence interval is calculated by a procedure that, under its assumptions and repeated sampling, covers a fixed unknown parameter at the stated frequency. The confidence level belongs to the procedure.

An individual frequentist 95% interval does not mean that the fixed parameter has a post-data 95% probability of lying inside it. For process effects, the experimental unit, model and variation must be appropriate. An apparently narrow interval can mislead if independence is wrongly assumed.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 12
Back to the term directory

Configuration baseline

Related search terms: configuration baseline

A configuration baseline is an identified system state designated as the reference for further work. It connects relevant hardware, software, settings and documentation. Changes are described against this state so that the configuration actually used remains traceable.

For a bioreactor, pump scaling, sensor assignment and recipe revision may belong to the baseline. An earlier functional test initially applies to its earlier state. After changes, assess which results remain applicable and which affected functions need renewed verification.

Foundations: Annex 11: Computerised Systems

Used in these chapters · 2
Back to the term directory

Configuration item

Related search terms: configuration item

A configuration item is a bounded object or group of components managed as one entity in configuration management. It can include hardware, software and associated information. Choose the boundary according to the change evidence required.

For a bioreactor, a defined control application and its parameters may form one configuration item. Changes then have an identifiable reference. Overly broad boundaries can conceal affected functions; overly fine boundaries can create work without improving understanding.

Foundations: Configuration Item

Back to the term directory

Conformity decision and decision rule

Related search terms: Conformity assessment, Decision rule, Decision rule

A conformity decision assesses acceptance against specified requirements using a decision rule. The rule specifies how the measured value and relevant measurement uncertainty enter that assessment.

Requirement tolerance limits and decision acceptance limits may differ. A guard band can change the risks of false acceptance or rejection. A confidence interval alone specifies neither the decision rule nor the accepted decision risk.

Foundations: Evaluation of measurement data — The role of measurement uncertainty in conformity assessment

Used in these chapters · 6
Back to the term directory

Confounding

Related search terms: Aliasing, Alias structure

Confounding means that a design does not allow certain influences to be identified separately. Under exact aliasing, different model terms have identical or proportional columns in the model matrix.

An observed coefficient may then represent a combination of several actual contributions. Additional repeats of the same unsuitable combinations do not resolve this structural ambiguity. Additional informative conditions or explicitly justified modelling assumptions are required.

Foundations: Fractional factorial designs

Used in these chapters · 3
Back to the term directory

Conjugate acid–base pair

Related search terms: conjugate base, buffer forms

The members of a conjugate acid–base pair differ by one proton. Acid HA can release a proton to form its conjugate base A⁻. Actual charges depend on the chemical species; not every acid is electrically neutral.

A buffer balance first assigns added strong acid to the corresponding conversion of buffer forms and then evaluates equilibrium. Constant total buffer inventory does not imply a constant ratio between the forms.

Foundations: 14.6 Buffers

Used in these chapters · 1
Back to the term directory

Conservative tracer

A conservative tracer is neither formed nor consumed within the chosen boundary and adequately follows the transport being investigated. Its balance supports assessment of flow and mixing.

Adsorption, reaction, phase transfer or degradation violates this assumption. Suitability must be assessed for the marker, medium, materials and experiment duration. Conservativeness applies to a particular system, experiment duration and phase. A soluble substance may be retained at a surface or follow a sampling route differently from the cell of interest. Chemical stability alone therefore does not establish that every biologically relevant transport pathway is represented adequately.

Foundations: Chapter 16: Distributions of Residence Times for Chemical Reactors

Back to the term directory

Contamination

Related search terms: unwanted contamination

Contamination is the unintended introduction or presence of unwanted biological, chemical or particulate material. In a bioreactor, foreign microorganisms can alter the culture, cleaning agents can inhibit growth, and particles can affect the product or subsequent processing. The vessel is not necessarily the source: media, gas supplies, personnel, seals and connection procedures may also contribute.

An unexpected pH change or unusual turbidity can indicate contamination but does not establish it. Process faults and changes in the production organism can produce similar signals. An investigation therefore needs to confirm the finding, identify possible entry routes and consider affected materials. The intended culture itself is not contamination when its identity and use are consistent with the defined process.

Used in these chapters · 19
Back to the term directory

Contamination control strategy (CCS)

Related search terms: CCS

A contamination control strategy connects measures against unwanted microbial, particulate and, where relevant, pyrogenic contamination into a coherent approach. It considers sources, entry routes and the interaction between design, procedures and monitoring. For a sterile process, raw-material quality, connections, cleaning and preservation of protected regions need to work together.

An explicit regulatory example is the CCS described in EU GMP Annex 1 for sterile medicinal products for human use. That formal requirement must not be applied indiscriminately to every research laboratory. The technical principle remains useful: an additional final test cannot compensate for a systematically open contamination route. The strategy should explain why the combined measures are effective and how changes or recurring findings are assessed. A list of existing procedures alone does not explain those relationships.

Back to the term directory

Continuous culture

Continuous culture receives fresh medium while culture broth or a separated liquid stream leaves the reactor. Balanced liquid flows keep the working volume approximately constant. Several operating concepts fit this description: suspended cells leave with the outlet in a chemostat, whereas perfusion retains a substantial proportion of the cells.

Continuous exchange can support extended production and experiments under comparable conditions. It does not automatically establish a steady state. Feed fluctuations, biological adaptation and deposits may continue changing the culture. Over long runs, sterile connections, reliable medium supply, dependable measurements and clear assignment of harvested material to production periods become particularly important when evaluating process performance.

Used in these chapters · 2
Back to the term directory

Contract Development and Manufacturing Organisation (CDMO)

Related search terms: CDMO, contract manufacturing

A CDMO provides development and manufacturing services to other organisations. Its scope may range from process development to particular production and analytical tasks. Not every contract manufacturer automatically provides all development activities.

For a bioprocess, agree service scope, data access, responsibilities and transfer between locations explicitly. External capacity cannot be compared directly with reactor purchase price when staffing, analysis and documentation differ in scope. A provider’s capacity figures also require a technical and temporal reference basis.

Used in these chapters · 3
Back to the term directory

Contribution margin

Related search terms: unit contribution margin, total contribution margin, contribution margins, incremental contribution, lost contribution

Contribution margin is revenue minus variable costs. Unit contribution margin is selling price per unit minus variable cost per unit, expressed in currency per unit. Total contribution margin concerns revenue and variable costs for the entire quantity sold. With a uniform unit contribution margin, the total equals that amount multiplied by units sold.

This amount is available to cover fixed costs; a positive contribution margin is not yet profit. Period, quantity and cost classification must align. Contribution margin is a monetary amount; the relative contribution margin ratio is a different measure.

Foundations: 3.1 Explain Contribution Margin and Calculate Contribution Margin per Unit, Contribution Margin Ratio, and Total Contribution Margin

Used in these chapters · 3
Back to the term directory

Contribution margin ratio

Related search terms: contribution margin ratio

The contribution margin ratio divides contribution margin by the corresponding revenue. In a simple model, this revenue fraction remains after variable costs to cover fixed costs and profit.

The ratio depends on which costs are actually treated as volume-dependent. In fermentation, additional cleaning runs or shift changes can introduce step costs. These steps should be modelled separately instead of hidden behind one constant ratio across every output level.

Foundations: 3.2 Break-Even Point

Back to the term directory

Convection

Related search terms: Convective transport

Convection is transport of energy or material through fluid motion. The motion may be forced by an agitator or driven by density differences. In heat-transfer analysis, flow and local transport through the boundary layer act together; a mean fluid velocity therefore does not determine the complete heat-transfer behaviour.

Circulation can bring fresh medium to a carrier without removing diffusion distances inside it. Convection and diffusion should consequently be distinguished. Troubleshooting asks whether flow reaches the relevant region, whether it fluctuates over time and which local boundary layer remains. A high total circulation rate does not guarantee adequate supply to every reactor zone.

Foundations: OpenStax University Physics 2: Mechanisms of heat transfer

Back to the term directory

Convolution

Convolution combines an input history with the impulse response of a linear time-invariant system to obtain its output. Shifted contributions are integrated or discretely summed.

A broad tracer pulse and slow probe can broaden an observed curve. Their effects must be distinguished from a genuinely broad residence-time distribution. For causal continuous signals, y(t) = ∫₀ᵗh(t − s)u(s)ds with initial conditions handled appropriately. Input u and impulse response h are combined across past times. A finite tracer pulse is therefore not represented by simply multiplying the reactor response and input point by point.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

Copy number variation (CNV)

Copy number variation occurs when a defined DNA segment is present in different numbers of copies across genomes or cell populations. The segment may contain one gene, several genes or non-coding regions. A copy-number result requires a reference, measurement method and normalisation basis.

In production cells, the copy number of an introduced segment and its actual expression are separate questions. More copies do not guarantee proportionally more product. In heterogeneous populations, a mean value may describe many different cells rather than a largely uniform population; the interpretation must reflect that distinction.

Foundations: NHGRI: Copy number variation (CNV)

Back to the term directory

Correlation

Related search terms: Correlation coefficient, Pearson correlation

Pearson correlation normalises covariance by the product of the standard deviations. When these are positive and finite, it lies between −1 and +1 and describes linear statistical association.

Correlation establishes neither causal direction nor mechanism. A third influence such as culture age can change two process trajectories together. Zero linear correlation also does not exclude a nonlinear relationship, so the data pattern must still be examined.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 17
Back to the term directory

Cosine response

Related search terms: Cosine correction

An ideal planar irradiance measurement weights oblique directional radiation by the cosine of its angle to the surface normal. This represents projection onto the surface considered.

A sensor’s cosine-response error can bias measurements under oblique illumination. Orientation, shading and mounting therefore belong in the measurement record. A scalar-radiation sensor uses a different angular weighting; it is not simply a better-corrected planar sensor.

Foundations: Measuring PPFD and PPFFR with underwater sensors

Back to the term directory

Cost equality and break-even

Related search terms: break-even, cost equality

Break-even identifies a point at which defined quantities balance. Often it means equality of revenue and cost. In an option comparison it may instead mean equality of two bounded cost totals; distinguish these meanings.

A synthetic bioreactor comparison can calculate the batch count at which lower consumable costs offset higher initial spending. That cost equality establishes neither profit nor demand. It applies only to the stated price, quantity and performance assumptions.

Used in these chapters · 1
Back to the term directory

Counterion

Related search terms: counterions

A counterion balances the charge of an ionic component in a salt or specified formulation. Sodium in an organic-acid sodium salt is therefore part of the material input, not merely a naming detail.

Switching between a free acid, sodium salt and hydrochloride may introduce different ions at equal organic-component inventory. Media comparisons need these contributions and subsequent pH adjustments accounted for before assessing biological equivalence.

Foundations: 11965 – DMEM, high glucose: formulation

Used in these chapters · 6
Back to the term directory

Covariance

Covariance describes joint deviations of two quantities from their expectations. Its unit is the product of their units and it may be positive, negative or zero.

Covariance terms in uncertainty propagation may arise from shared calibration. For a difference, Var(X − Y) = Var(X) + Var(Y) − 2 Cov(X,Y). Zero covariance does not generally imply statistical independence.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 6
Back to the term directory

Coverage factor

Coverage factor k connects combined standard uncertainty to expanded uncertainty. Its selection depends on intended interval interpretation and available distribution information.

Do not describe a customary factor as guaranteeing a particular probability. Report factor, model and any claimed coverage together. One-sided decision limits also differ from two-sided uncertainty intervals. Changing k while keeping u_c fixed changes the reported interval but improves neither the sensor nor sampling.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 4
Back to the term directory

Crabtree effect

Related search terms: Aerobic alcoholic fermentation

The Crabtree effect describes ethanol formation by certain yeasts despite the presence of oxygen when carbon loading is sufficiently high. Cells then use fermentative and respiratory pathways alongside one another. The response can include both rapid reactions to increased sugar availability and longer-term metabolic adaptation. Its expression depends on species, strain and cultivation conditions.

For biomass or protein production, ethanol formation may divert useful carbon, whereas in ethanol manufacture the same diversion is part of the objective. Increasing aeration alone will not necessarily remove it. Assessment should therefore examine sugar uptake, respiration and ethanol formation together. Describing a yeast as Crabtree-positive does not establish one universal critical glucose concentration for every process.

Back to the term directory

Critical path

Related search terms: critical path

A critical path is a chain of timing dependencies determining earliest completion in a defined activity network. Extending a binding activity shifts completion when the sequence cannot compensate.

Resource limits can create dependencies absent from a material-only network. A visually shorter alternative is therefore plausible only after shared equipment and staffing are considered. Report timing slack against actual modelled conditions.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 1
Back to the term directory

Critical process parameter (CPP)

Related search terms: CPP, CPPs

Within pharmaceutical quality practice, a CPP is a process parameter whose variability affects a critical quality attribute and therefore needs suitable monitoring or control.

A recorded temperature or feed rate is not critical merely because it is measurable. Classification needs a supported relationship to product quality and a defined range. Correlation without suitable experimental design may arise from shared causes and does not automatically establish that relationship.

Foundations: Pharmaceutical Development

Used in these chapters · 1
Back to the term directory

Critical quality attribute (CQA)

Related search terms: CQA, CQAs

Within pharmaceutical development, a CQA is a quality characteristic whose appropriate limitation supports intended product quality. It concerns a product property, such as relevant activity or purity, rather than merely a recorded process setpoint.

Criticality follows product understanding and evidence. High protein mass with poor activity may miss the intended quality. Applying this reasoning to technical enzymes does not automatically impose pharmaceutical obligations.

Foundations: Pharmaceutical Development

Used in these chapters · 1
Back to the term directory

Cross-contamination

Related search terms: carryover between processes

Cross-contamination is the unintended transfer of material from another culture, batch or product line. Transferred material can include living cells, product residues, nucleic acids or processing aids. Shared equipment, inadequately cleaned pipework and incorrectly identified connections create possible routes. The term therefore extends beyond the entry of environmental microorganisms.

In cell culture, a foreign cell line may progressively replace the intended population without being detected by a routine bacterial contamination test. In multiproduct equipment, chemical carryover may instead be the principal concern. Controls must address the actual transfer route, for example spatial or temporal segregation, clear identification and demonstrated cleaning effectiveness. Separating cultures does not replace identity testing when a mix-up or admixture remains plausible.

Used in these chapters · 1
Back to the term directory

Cryptographic hash

Related search terms: cryptographic hash, hash value

A cryptographic hash function maps data to a compact value and is designed to make specified manipulation and collision searches computationally impractical. Identical unchanged input produces the same value with the same function. Hashing is not encryption and does not conceal data.

For archived process files, a trusted reference value can help detect later alteration. A hash alone proves neither authorship nor scientific correctness. If both file and reference are replaced without control, the necessary independent comparison is lost.

Foundations: Cryptographic Hash Function

Back to the term directory

Crystallisation

Formation and growth of an ordered crystalline solid phase from another phase, for example a supersaturated solution. It can recover or purify suitable compounds during downstream processing, but is not suitable for every bioproduct.

Recovery, purity, crystal form and particle-size distribution are distinct outcomes. Retained mother liquor or included impurities can affect the product basis. Compound quantity in crystals is therefore not established solely by the mass of a still-wet solid.

Foundations: 11.3 Solubility, Chemistry2e

Used in these chapters · 2
Back to the term directory

CSV file

Related search terms: CSV, Comma-separated values

A CSV file stores tabular values as text records containing separated fields. RFC 4180 describes a common comma-separated arrangement with an optional header and quotation rules. It is an informational description; software implementations may follow different conventions.

For bioprocess data, document delimiter, character encoding, decimal marker, time format and the meaning of empty fields. A numerical column alone supplies neither its unit nor sample identity. During import, check whether a value such as 1,25 was interpreted as one decimal number or two fields. Readable CSV establishes neither complete raw data nor traceable changes; provenance and acquisition context are also needed.

Foundations: RFC 4180: Common format and MIME type for CSV files

Used in these chapters · 28
Back to the term directory

Culture medium

Related search terms: Growth medium

A culture medium supplies the chemical environment and usable nutrients required by a culture. Its roles include providing building blocks and energy sources, together with suitable salt and buffering conditions. The required components depend on the organism’s biosynthetic capabilities and the production objective. A medium designed for cell expansion is not necessarily ideal for maximum product formation.

The medium changes during cultivation: nutrients are consumed, metabolic products accumulate and some components can degrade chemically or precipitate. A formulation therefore describes the starting condition only. Process interpretation also needs to consider which components remain biologically available and how their concentrations change over time. Identical starting recipes can consequently produce different environments when cellular consumption differs.

Used in these chapters · 12
Back to the term directory

Current ratio

Related search terms: current ratio

The current ratio divides current assets by current liabilities. Both amounts must use the same reporting date and boundary. The ordinary ratio is undefined when current liabilities are zero.

For equipment projects, this measure does not replace a payment schedule. Inventory can be technically necessary, slow to realise or unsaleable. A favourable ratio can therefore coexist with immediate funding needs for spare parts or qualification work.

Foundations: 19.1 What Is Working Capital?

Back to the term directory

Cyanobacteria

Related search terms: Blue-green algae

Cyanobacteria are bacteria that perform oxygenic photosynthesis and release oxygen. Despite their traditional name, blue-green algae, they have neither a nucleus nor the chloroplasts found in eukaryotic algae. Their photosynthetic structures are organised within the bacterial cell. Some species can also use molecular nitrogen, but this capability is by no means universal.

Biomass and pigments are among their production targets. Cultivation requires coordinated provision of light, inorganic carbon and suitable mineral nutrients. The considerable diversity within the group prevents general conclusions about pH preference, salt tolerance or product suitability. Strong culture colour likewise cannot directly establish rapid growth or a high concentration of the particular pigment sought.

Used in these chapters · 2
Back to the term directory

D

D-value

Related search terms: decimal reduction time

The D-value is the time required under specified conditions to reduce a viable population by one decimal logarithm, or a factor of ten. For thermal treatment, the temperature is stated, for example D at 121 °C. Assuming log-linear inactivation, log₁₀(N₀/N) = t/D, where N₀ and N are the initial and surviving populations, and t and D use the same unit of time.

A D-value belongs to a particular organism in a particular environment. Moisture, medium and physiological state can change it, so calculations cannot be transferred to different materials without appropriate data. Shoulders or tails in a survival curve also violate the simple model. The value describes inactivation, not prevention of subsequent recontamination.

Used in these chapters · 2
Back to the term directory

Daily light integral

Related search terms: DLI

Daily light integral is the time integral of a defined photosynthetically active photon flux density over one day, usually in mol m⁻² d⁻¹. It describes daily photon quantity per measurement area.

For constant PPFD, the value is multiplied by illumination time; variable light requires time integration. Equal daily integrals can contain very different peaks and dark periods. The integral alone therefore predicts neither identical biological responses nor equivalent spatial light supply.

Foundations: Measuring PPFD and PPFFR with underwater sensors

Used in these chapters · 1
Back to the term directory

Data integrity

Data integrity concerns whether information remains complete, consistent and reliable throughout its life cycle. Bioprocess records require more than final values: provenance, timestamps, units, equipment status and traceable changes also matter. A numerically correct temperature can be practically unusable without the associated batch or time zone.

Effective arrangements combine technical safeguards with defined working procedures, access rights and verified restoration of backed-up data. These principles also support research, independently of a particular regulatory setting. An attractive plot or read-only PDF alone does not demonstrate data integrity. If raw data, excluded observations or processing steps are missing, the underlying evidence may no longer be independently assessable or reproducible.

Used in these chapters · 1
Back to the term directory

Data leakage

Data leakage in model assessment occurs when model development uses information that should be unavailable at the intended prediction time or from an independent test set. Measured performance can consequently appear too favourable.

Examples include normalisation learned from all data and splitting neighbouring time points from one culture between training and testing. Data splitting and preprocessing are therefore defined before fitting to match later use. A confidentiality breach is a different meaning of the term data leak.

Foundations: Common pitfalls and recommended practices

Back to the term directory

Data migration

Related search terms: data migration

Data migration transfers data into another system or format. Information and meaning required for the intended purpose need preservation. Technically successful transfer does not fully establish this.

When changing bioreactor software, also verify units, timestamps, events and associations. Some records require continued analytical functionality. A PDF image or numerical list may then represent only part of the former dataset.

Foundations: Annex 11: Computerised Systems · Data Integrity and Compliance With Drug CGMP: Questions and Answers

Used in these chapters · 1
Back to the term directory

Data-driven model

A data-driven model derives a relationship between inputs and responses substantially from observed data. It can include simple regression as well as more complex learning methods.

Its claims are limited by data coverage, selection and preprocessing. High fit quality may reflect unwanted dependence on elapsed time or batch identity. Independent tests within the appropriate domain therefore support the later decision.

Foundations: Machine learning — CSRC Glossary · Common pitfalls and recommended practices

Used in these chapters · 1
Back to the term directory

Dead leg

Related search terms: dead space, poorly swept branch

A dead leg is a region that is inadequately swept, cleaned, drained or sterilised during the process step under consideration. Examples include long branches, unsuitable sensor connections and cavities behind seals. The description is functional: a region may be sufficiently mixed during production yet poorly reached during cleaning.

Geometrical criteria can assist design, but they do not replace consideration of flow direction, installation orientation and operating state. A single universal length-to-diameter ratio therefore cannot prove the hygienic suitability of every fitting. Residues may remain or microorganisms may survive in an unfavourable region. A useful assessment follows the actual liquid and steam paths, including valve positions, and establishes whether the critical area receives adequate treatment.

Used in these chapters · 2
Back to the term directory

Dead time

Dead time is the interval between a change at a process input and the first observable start of its effect at the chosen output. A liquid sample, for example, must travel along a transfer line before its changed composition reaches an analyser. This pure delay differs from a subsequent gradual sensor response.

Dead time limits how quickly a control loop can usefully react. Aggressive control may issue repeated corrections while the effects of earlier actions are still travelling through the system. Transport delays and timestamps therefore matter when comparing data. A fixed time shift is not always sufficient, because changing flow, mixing and sample preparation can create variable delay or additional temporal spreading.

Used in these chapters · 6
Back to the term directory

Deconvolution

Deconvolution attempts to recover an input or system response from an observed convolved signal. At least one contributing response must be sufficiently known.

Noise and missing frequency information can make the inverse problem unstable. Regularisation and uncertainty assessment are needed; reconstruction does not replace an adequately resolved experiment. Separation requires a known input or independently characterised measurement chain and a mathematical treatment suited to the model. Rapid noise may be strongly amplified by inversion. A numerically sharp reconstructed curve therefore does not demonstrate that equally rapid physical events were actually resolved by the original measurements.

Used in these chapters · 2
Back to the term directory

Defence in depth

Related search terms: defense in depth, defence in depth

Defence in depth combines different technical and organisational safeguards. Failure of one measure should not immediately remove every protective effect. The layers must fit actual workflows and dependencies.

In a bioprocess environment, controlled access, limited permissions and traceable changes can complement one another. Several similar measures sharing the same weakness do not necessarily provide independent protection. The strategy is not a promise of complete security, but a framework for coordinated safeguards.

Foundations: Defense In Depth

Back to the term directory

Degree of reduction

A stoichiometric measure of formal reduction content relative to stated reference substances. For neutral CHON compounds relative to CO₂, H₂O and NH₃, γ = 4C + H − 2O − 3N per molecule or corresponding amount-of-substance basis.

It supplements elemental accounting with an electron-equivalent balance. Reference quantity, charge and additional elements must be handled consistently. It is not a directly measured ATP yield; compounds containing equal carbon can have different reduction contents.

Used in these chapters · 1
Back to the term directory

Degrees of freedom

Related search terms: Residual degrees of freedom

Degrees of freedom describe the number of independent pieces of information remaining after estimated quantities or other constraints are accounted for. An ordinary linear model with n observations and p independently estimable parameters has n − p residual degrees of freedom.

This count enters residual-variance estimation and appropriate reference distributions. It is not automatically the number of measured samples. Dependence, block structure and the chosen model can substantially change the relevant information.

Foundations: Testing missing or misspecified model terms

Used in these chapters · 7
Back to the term directory

Deliquescence

Deliquescence is uptake of water vapour by a solid until a liquid solution forms under suitable surrounding conditions. It is more specific than modest moisture uptake.

This transition can strongly alter raw-material handling and quantity basis. Conditions depend on substance and temperature; the term supplies no universal humidity limit for medium salts. An affected weighed quantity requires appropriate identity and assay assessment.

Foundations: Salt crystallization and deliquescence triggered by humidity cycles in nanopores

Back to the term directory

Denitrification

Denitrification reduces oxidised nitrogen compounds through several steps to gaseous nitrogen. In conventional heterotrophic wastewater balances, organic carbon supplies electrons while nitrate or nitrite acts as electron acceptor.

Complete nitrate reduction to N₂ corresponds stoichiometrically to 40/14 kg O₂ equivalent per kg nitrate-N. Incomplete conversion may leave other products such as N₂O. Gas load inferred from an incomplete balance is therefore not a direct measurement of complete denitrification.

Foundations: Nutrient Control Design Manual

Used in these chapters · 5
Back to the term directory

Density

Density is the mass of a substance or mixture divided by its corresponding volume. Common units are kg/m³ and kg/L. It depends on state and composition. For an ideal-gas approximation at constant temperature and composition, density rises in proportion to absolute pressure. Liquid density should not automatically be treated as invariant either.

A litre of concentrated feed therefore need not weigh one kilogram. Substituting water density for a substantially more concentrated solution introduces a systematic error into converted mass and substrate flows. A density value needs its reference temperature, measurement or data source and phase definition. A gas-containing suspension also has a different average density from its degassed liquid phase.

Foundations: OpenStax Chemistry 2e: Gaseous substances and mixtures

Used in these chapters · 33
Back to the term directory

Depth filtration

Related search terms: depth filter

A depth filter retains components within a three-dimensional filter structure. Several capture and interaction mechanisms may contribute, differing conceptually from separation described only at an ideal thin surface.

Usable loading depends on feed and endpoint. Turbidity, pressure rise and product loss can impose different limits. Nominal area or pore designation therefore cannot replace examination of the complete harvest quantity under suitable conditions.

Foundations: Analysis of fouling and breakthrough of process related impurities during depth filtration using confocal microscopy

Used in these chapters · 2
Back to the term directory

Depyrogenation

Related search terms: pyrogen removal

Depyrogenation removes or inactivates fever-inducing substances in a defined material or system. In many technical applications, the principal objective is reduction of bacterial endotoxins. Depending on the object being treated, suitable methods may include demonstrated dry-heat treatment or an effective removal step. Selection must consider material compatibility together with the required reduction.

Depyrogenation and sterilisation are different tasks. A process can reliably inactivate bacteria without sufficiently reducing the endotoxins originating from them. Conversely, suitable endotoxin reduction does not address every other possible pyrogen. Assessment therefore requires a clearly identified target, appropriate recovery and justified acceptance criteria established beforehand. A procedure suitable for empty glass containers cannot simply be adopted for complex culture solutions.

Back to the term directory

Design of experiments

Related search terms: DoE, DOE

Design of experiments arranges factor combinations, experimental units and allocation so that the resulting data can answer a specified question. A design connects physically permissible settings with an appropriate analysis.

For a bioreactor study, the response, independent run, order, replication and possible block effects are specified beforehand. Varying several factors together can reveal interactions. A design alone establishes neither causality without further assumptions nor transferability to another scale.

Foundations: Two-level full factorial designs · Randomized block designs

Used in these chapters · 2
Back to the term directory

Design qualification (DQ)

Related search terms: design qualification

Design qualification documents whether the proposed construction is suitable for its intended purpose. It uses the requirements to identify avoidable problems before they become part of the finished equipment. For a bioreactor, the review may cover working volume, material selection, cleaning paths and the intended sterile boundary. A traceable connection between requirements and design decisions makes the assessment clearer.

DQ is not simply general drawing approval. A formally complete drawing can overlook a functional risk, such as a branch that cannot be vented adequately. Reviewing the design also does not prove that the eventual equipment has been built correctly. DQ forms part of pharmaceutical qualification; elsewhere, technical design review remains useful without automatically creating identical documentation obligations.

Used in these chapters · 1
Back to the term directory

Desorption

Related search terms: surface release

Desorption is departure of a previously adsorbed substance from a surface. Changed composition or other appropriate conditions may promote it. Controlled release can contribute to recovering bound product in a separation process.

A transient increase in outlet titre may therefore come from earlier stored product. Include decreasing bound inventory in the balance. A concentration rise alone proves neither greater culture productivity nor a specific molecular release mechanism.

Foundations: CaptivA HF Protein A Affinity Resin · Protein preparation handbook

Used in these chapters · 2
Back to the term directory

Detection limit

Related search terms: LOD, limit of detection

The detection limit is the smallest amount or concentration whose presence can be reliably distinguished from background by a suitable procedure under specified conditions. It concerns whether a substance is detectable rather than automatically establishing how accurately its quantity can be determined.

The limit depends on matrix, preparation, blanks, equipment and the decision procedure. A manufacturer’s value for a clean standard solution must therefore not be transferred to culture broth without verification. A result below the detection limit also does not mean that the true concentration is exactly zero. Reports need the limit, units and method. Calculated estimates should be checked using suitable samples near the relevant range.

Used in these chapters · 9
Back to the term directory

Diafiltration (DF)

Related search terms: DF, UF/DF

Diafiltration changes the composition of a retained product solution by adding exchange liquid and removing permeate. Addition may be continuous at approximately constant volume or follow another explicitly described sequence.

At constant volume with complete solute passage and solute-free incoming buffer, the ideal relation is c/c₀ = exp(−N). Partial retention, binding or buffer input changes the balance. Diavolume count alone therefore establishes neither complete removal nor a specified product purity.

Foundations: KrosFlo KR2i Tangential Flow Filtration System · Protein preparation handbook

Used in these chapters · 5
Back to the term directory

Diavolume

Related search terms: diavolumes

A diavolume expresses exchange-liquid or permeate quantity relative to a defined retentate volume during diafiltration. At a constant 200 L retentate volume, five diavolumes correspond to 1,000 L of added buffer and the same removed permeate quantity.

With changing retentate volume, state the reference-volume definition. Otherwise diavolumes from different strategies cannot be compared directly. The measure describes liquid exchange; removal additionally depends on solute passage and initial and incoming concentrations.

Foundations: KrosFlo KR2i Tangential Flow Filtration System · Protein preparation handbook

Used in these chapters · 3
Back to the term directory

Diffusion

Diffusion is material transport arising from random particle motion. In a simple isothermal dilute solution, a Fickian model describes net transport down a concentration gradient. The diffusion coefficient has dimensions of area per time, such as m²/s. This is an approximation under stated conditions rather than an unrestricted description of every multicomponent system.

Oxygen can be available at the surface of a colonised carrier while becoming scarce inside if consumption outpaces transport. A high average reactor concentration therefore does not establish uniform supply. Transport distance matters when comparing geometries: in a simple model, characteristic diffusion time scales with the square of distance. Doubling the distance then gives roughly four times the time, rather than twice.

Foundations: MIT: Conceptual model for diffusion

Used in these chapters · 4
Back to the term directory

Diffusive-flow test

Related search terms: forward-flow test, diffusion test

A diffusive-flow test measures gas flow through a wetted filter membrane at a specified pressure below its bubble point. An intact membrane still permits limited gas transport through the liquid occupying its pores. An additional passage or leak can increase the measured flow. The result is therefore compared with a limit established for the membrane area, material and test conditions.

A large filter area has a different baseline flow from a small one even when both are intact. Temperature changes, incomplete wetting and leaks outside the membrane also need consideration. Pressure decay can be used to infer flow, but requires a suitable, characterised test arrangement. The method demonstrates integrity only within its established relationship with the required retention performance.

Back to the term directory

Digestate

Digestate is the material remaining after anaerobic digestion, containing liquid and solid fractions. It includes unconverted material, microbial biomass, water and remaining nutrients in an altered composition.

Gas formation does not remove all original elements from the liquid and solids. Digestate quality, further treatment and possible use depend on feedstocks and process conditions. The name alone establishes neither hygienic acceptability nor general suitability as fertiliser.

Foundations: How Does Anaerobic Digestion Work?

Used in these chapters · 2
Back to the term directory

Digital certificate

Related search terms: public-key certificate

A digital certificate associates a public cryptographic key with an identified entity and carries a digital signature. It includes further information such as issuer and validity period. It is not a quality certificate for the biological performance of equipment.

In technical communication, a certificate can help verify the counterpart. Bioreactor systems require appropriate identity association, renewal and trust in the issuer. A technically valid certificate does not automatically grant an application every equipment permission.

Foundations: Certificate

Back to the term directory

Digital twin

A digital twin is a digital representation associated with a real system and synchronised with suitable system data for a defined purpose. Update rate and scope must match the intended use.

A static simulation does not become a twin merely through three-dimensional presentation. Prediction performance, uncertainty and domain are assessed for the specific application. Automatic write access to the reactor is not a necessary defining feature and requires separate assessment.

Foundations: Digital Twins for Advanced Manufacturing

Used in these chapters · 2
Back to the term directory

Dilution rate

Dilution rate expresses liquid throughput relative to working volume: D = F/V. If medium flow F is in L/h and culture volume V is in L, D has units of h⁻¹. The simple relationship requires a clearly defined volume basis and is typically applied to continuous operation at constant volume.

In an ideal chemostat without cell retention, D links throughput to the steady-state growth rate. This equality does not describe cellular growth in perfusion. When several inlet and outlet streams exist, the flows included in the calculation must be stated. Dilution rate also does not directly give the fraction of original liquid remaining after one hour.

Used in these chapters · 5
Back to the term directory

Dimensionless groups

Related search terms: Similarity parameters

Dimensionless groups combine physical quantities so that their units cancel completely. They often compare competing effects, such as inertia and viscosity in the Reynolds number. This helps organise relationships between differently sized equipment more clearly than treating every dimension and operating variable independently.

The selected groups must suit the question being investigated. Matching Reynolds number, for example, does not completely describe gas interfaces or heat transfer. Different definitions of the same named group may also produce different numerical values. Dimensional analysis organises possible relationships but does not automatically supply empirical coefficients or validity limits. A process comparison should therefore identify the physical meaning, reference quantities and important assumptions of every group used.

Back to the term directory

Discounting

Related search terms: discounting, present value, discount factor

Discounting weights a future payment using a stated rate and time interval to calculate present value. With annual compounding, a payment after t years has factor 1/(1+r)^t. The rate r is a model assumption.

Bioreactor comparisons should expose payment timing, price basis and any residual value. Discounted costs differ from the sum of euros paid. They replace neither technical suitability assessment nor evaluation of actual affordability.

Used in these chapters · 3
Back to the term directory

Disinfection

Related search terms: disinfecting treatment

Disinfection reduces or inactivates microorganisms to a level or effect defined for the application. Chemical agents and physical methods differ in the groups of organisms they affect. Performance depends on concentration, contact time, temperature and the presence of soil. For a liquid chemical surface disinfectant, adequate wetting throughout the required contact period is also essential.

Disinfection is not equivalent to sterilisation: an agent effective against vegetative bacteria may not adequately inactivate endospores. A product label does not replace assessment of the actual surface and application. In bioprocessing, material compatibility and possible residues are additional concerns. Cleaning should remove obstructing deposits; a disinfectant should not be expected to compensate for unsuitable equipment design or poorly executed cleaning.

Used in these chapters · 2
Back to the term directory

Disposable assembly

Related search terms: disposable assembly, single-use assembly

A disposable assembly combines single-use components for a defined purpose. It can include bags, tubing, filters, connectors and sensor regions. Its exact arrangement belongs to the configuration and is not specified by the term alone.

In bioreactor processing, connections, fluid volumes, materials and intended use affect suitability. A visually similar assembly is not automatically interchangeable. Assess changes against process, product-contact and integrity requirements.

Used in these chapters · 1
Back to the term directory

Dissolved carbon dioxide

Related search terms: pCO₂, dCO₂

Dissolved carbon dioxide is linked to the carbonate buffering system and to carbon dioxide partial pressure. Process sensors commonly report a pCO₂ associated with the liquid, for example in mbar, using a gas-permeable membrane and a suitable measurement principle. This value differs from carbon dioxide concentration in the exhaust gas.

Monitoring helps reveal inadequate carbon dioxide removal at high cell density. Controlled pH does not exclude elevated CO₂ exposure, because base addition can partly compensate for acidification. Conversely, pCO₂ does not represent all inorganic carbon, including bicarbonate. Degassing and temperature changes rapidly alter withdrawn samples, making prompt, controlled handling essential when comparing them with inline measurements.

Used in these chapters · 1
Back to the term directory

Dissolved oxygen measurement

Related search terms: DO measurement

Dissolved oxygen measurement describes molecular oxygen present in the culture liquid. Optical sensors use oxygen-dependent quenching or changes in luminescence lifetime; amperometric sensors measure current from an electrochemical oxygen reaction. Readings may represent concentration, such as mg/L, or a percentage of a defined saturation reference.

Interpretation and control require known temperature, pressure and calibration reference conditions. A reading of 100% air saturation does not mean that the medium contains 100% oxygen. It also describes a local concentration rather than the oxygen uptake rate of the entire culture. Bubbles on the sensing surface, inadequate liquid movement or unsuitable positioning can compromise its relevance to cellular oxygen supply.

Used in these chapters · 13
Back to the term directory

DNA ligation

Covalent joining of suitable DNA ends through bonds in the sugar–phosphate backbone, distinct from complementary pairing alone.

The resulting construct still requires verification. Evidence of joining, correct orientation and an unchanged target sequence answer different questions.

Foundations: Addgene

Back to the term directory

DNA – deoxyribonucleic acid

Related search terms: DNA, Deoxyribonucleic acid

A nucleic acid whose base sequence carries genetic information. Cellular DNA typically comprises two complementary strands with deoxyribose-phosphate backbones and adenine, cytosine, guanine and thymine bases.

Detecting a DNA segment does not automatically demonstrate expression or function of its product. Bank records therefore distinguish material identity, genetic findings and product function. State the sequence examined and the resolution of the evidence.

Foundations: Deoxyribonucleic acid

Back to the term directory

DO-stat feeding

DO-stat feeding uses dissolved oxygen as an indirect indicator of nutrient demand. When a carbon source is exhausted, for example, oxygen uptake may decrease and measured dissolved oxygen may rise. A suitable algorithm recognises this behaviour and adds substrate or changes the feed rate.

The method requires an established relationship between substrate supply and oxygen response in the actual process. Rising DO may also result from increased aeration, declining cellular activity or a measurement fault. Active oxygen control can suppress the signal of interest. DO-stat is therefore neither a direct glucose measurement nor another name for ordinary DO control: it adjusts feeding using an interpreted oxygen signal.

Back to the term directory

Docosahexaenoic acid

Related search terms: DHA

A long-chain omega-3 fatty acid with 22 carbon atoms and six double bonds, commonly called DHA or 22:6 n-3. It is a defined chemical component rather than the entire lipid or oil fraction of a product.

Total oil, DHA fraction and recovered DHA quantity are separate production measures. A percentage must state whether its basis is fatty acids, total oil or dry mass. The compound name alone establishes neither a health effect nor authorisation for use.

Foundations: Omega-3 fatty acids: health professional fact sheet

Used in these chapters · 1
Back to the term directory

Doubling time

Related search terms: Population doubling time

Doubling time is the interval required for exponentially growing biomass or a cell population to double. With constant specific growth rate, td = ln(2)/μ. If μ is expressed in h⁻¹, td is obtained in hours. A rate of 0.1 h⁻¹ therefore corresponds to approximately 6.9 hours. The relationship assumes stable growth conditions and an appropriate reference quantity.

An apparent doubling time calculated across the whole culture may combine adaptation, active proliferation and death, so it does not represent one consistent physiological state. Cell number and dry mass can also yield different doubling times if average cell mass changes. Comparisons should state the time interval examined and the biomass measure used.

Used in these chapters · 3
Back to the term directory

Downstream processing (DSP)

Related search terms: DSP, downstream

Downstream processing comprises operations after biological production that recover and prepare the required product form. These may include harvest, clarification, disruption, concentration, purification and formulation. Product location and target state determine actual scope.

Plan the sequence backwards from required final product. Every step changes quantities, composition and timing. High upstream formation is therefore not automatically equivalent to usable final quantity. State the upstream/downstream boundary explicitly for each comparison.

Foundations: Biochemical Processing: Overview, lecture2

Used in these chapters · 37
Back to the term directory

Draft tube

A draft tube is an open internal flow passage that directs liquid along a defined route and provides a separate return path through the surrounding space. It can create riser and downcomer regions in an airlift, while mechanically circulated systems may also use it to organise circulation loops. The tube guides flow rather than supplying the driving force itself.

Diameter, length and clearances at the bottom and upper end affect turning losses and exchange between regions. A restricted passage can limit the entire circulation loop. A draft tube also does not automatically create ideal plug flow: back-mixing, gas carry-under and local short-circuit paths remain possible and require assessment for the actual arrangement.

Used in these chapters · 1
Back to the term directory

Drainability

Related search terms: self-draining design

Drainability describes how completely liquid can be removed from equipment under specified conditions. Relevant features include slope, low points, valve orientation and connection geometry. Even small retained volumes may matter downstream, for example when rinse water dilutes medium or moist residues support microbial growth during a holding period.

The description “self-draining” needs a clear relationship with the operating state and acceptable residual volume. Surface tension, wetting and viscous liquids can leave residues despite a geometrical slope. Equipment may also drain differently in different valve positions. Tests should therefore reflect the actual operating sequence. Drainability supports cleaning and sterilisation, but on its own it is neither evidence of effective cleaning nor evidence of sterility.

Used in these chapters · 5
Back to the term directory

Dry cell weight

Related search terms: DCW, CDW

Dry cell weight is the cellular mass remaining after a defined separation, optional washing and drying procedure. Dividing by the original sample volume gives a biomass concentration, commonly in g/L. Removing variable water content makes the method useful as a reference for other biomass measurements and for material balances.

It does not measure viability: dead cells contribute alongside living cells, while incompletely removed salts or other solids can inflate the result. Excessive washing may instead lose material. Drying conditions and the criterion for sufficient mass constancy must be defined. Results from different procedures are therefore not automatically interchangeable. Weighing uncertainty can be substantial relative to very small samples or low biomass concentrations.

Back to the term directory

Dry heat

Related search terms: dry-heat sterilisation

Dry heat treats materials without the moist environment characteristic of steam sterilisation. It can be used for suitable heat-resistant components, such as certain glass or metal items. Because heat transfer and microbial inactivation differ from moist heat, treatment time and temperature cannot be exchanged directly between the two methods. Air circulation and the actual load also influence temperature distribution.

An adequate chamber reading does not prove that every component has reached the same temperature. Plastics, gaskets and coated surfaces may also suffer damage before treatment is complete. Under separately demonstrated conditions, dry heat can be used for depyrogenation. A sterilisation cycle is not established as effective for endotoxin reduction simply because its temperature is high.

Back to the term directory

Dry matter and dry basis

Related search terms: dry basis, loss on drying

Dry matter is the dry fraction established through a defined water-removal or analytical method. The method and any loss of other volatile constituents affect the result. Loss on drying is not inherently a selective water measurement.

An assay on a dry basis uses dry matter as reference mass. Applying it to weighed moist material requires consistent water and assay accounting. A water correction already included in the assay must not be applied again.

Used in these chapters · 3
Back to the term directory

Dry-gas basis

Related search terms: dry basis

On a dry-gas basis, mole fractions refer to gas excluding water vapour. On a wet basis, water vapour contributes to total gas amount.

A condenser changes composition and can affect other substances. Flow and analyser values must share a basis before uptake or production rates are calculated. For water-vapour fraction yH₂O, other components satisfy yi,wet = (1 − yH₂O)yi,dry. This conversion assumes that only the denominator changes. A physical drying step may additionally remove other substances; those losses are not automatically corrected by converting wet and dry fractions.

Foundations: Oxygen Uptake Rate Soft-Sensing via Dynamic kLa Computation

Used in these chapters · 2
Back to the term directory

Dulbecco’s Modified Eagle Medium

Related search terms: DMEM, Dulbecco Modified Eagle Medium

DMEM denotes a family of cell-culture basal media and stands for Dulbecco’s Modified Eagle Medium. Such media combine inorganic salts, amino acids, vitamins and a carbon source, among other constituents. The name alone does not specify one immutable formulation.

Variants differ, for example, in glucose concentration and the presence of glutamine, pyruvate or other components. Comparison therefore requires the actual product number, formulation and supplements added. A published DMEM example is neither automatically a complete growth medium for every cell line nor a universal target for osmolality or CO₂ supply.

Foundations: 11965 – DMEM, high glucose: formulation · Animal Cell Culture Guide

Used in these chapters · 1
Back to the term directory

Duty cycle

Duty cycle is the fraction of a periodic interval during which a signal or source is on. For rectangular pulses with unchanged peak output and no light in the off state, the time average is peak output multiplied by duty cycle.

Pulsed illumination additionally requires period, pulse width and spectral state. Equal averages at different duty cycles produce different peak exposure. Biological equivalence of these pulse sequences is a separate question requiring experimental evaluation.

Used in these chapters · 1
Back to the term directory

Dynamic binding capacity (DBC)

Related search terms: DBC

Dynamic binding capacity is product loading per chromatography-medium volume determined under defined flow and breakthrough conditions. Typical units are mg/mL or g/L resin. Test product, matrix and nominal residence time belong to its definition.

A larger number without matched test conditions is not a defensible resin comparison. Planned working load may justifiably be below measured capacity. Cycle count, ancillary time and recovery are additionally needed to size a complete campaign.

Foundations: CaptivA HF Protein A Affinity Resin

Used in these chapters · 2
Back to the term directory

E

Early Access

Related search terms: early access

Early Access provides access to a product or service before development or broader commercial introduction is complete. The phrase does not define a uniform technical maturity level. Available functions, support and possible changes require explicit description.

For a new cultivation platform, establish which results already have evidence and which will be developed with early users. Participation can support valuable learning, but is not equivalent to an unchanged, fully characterised production configuration.

Used in these chapters · 1
Back to the term directory

Eicosapentaenoic acid

Related search terms: EPA

An omega-3 fatty acid with 20 carbon atoms and five double bonds, often called EPA or 20:5 n-3. In environmental chapters EPA often instead means the US Environmental Protection Agency, so context must resolve the abbreviation.

Balance EPA content, total lipid quantity and recovery separately. A high percentage in a small biomass inventory can still produce little absolute product. This chemical definition makes no claim about a particular health application.

Foundations: Omega-3 fatty acids: health professional fact sheet

Used in these chapters · 6
Back to the term directory

Eigenvalue

Related search terms: Eigenvalues

An eigenvalue λ of a square matrix A satisfies A·v = λ·v for a non-zero eigenvector v. Along that direction, the linear map therefore acts as a scaling.

For a symmetric Hessian, the signs of its real eigenvalues help assess local curvature. Exclusively negative values indicate negative definiteness. Numerical values depend on variable scaling; they are not direct biological rate constants of a response-surface model.

Used in these chapters · 1
Back to the term directory

Electrical conductivity

Electrical conductivity describes how readily a liquid carries current through mobile ions. Process sensors determine it using electrodes or inductive arrangements. Common units include mS/cm and µS/cm; temperature or the applied temperature compensation must accompany the value because ion mobility changes with temperature.

Conductivity can reveal medium changes, dilution and cleaning phases. It remains a composite signal, however, and does not identify individual salts or nutrients. Different compositions can produce the same conductivity. Nor can conductivity be equated with osmolality without a matrix-specific relationship. A changed reading should therefore be checked against temperature, addition events and medium composition before attributing it to a biological cause.

Back to the term directory

Electron equivalent

An accounting quantity for transferred or formally transferable electrons in a defined redox reaction. One mole of electron equivalents corresponds to one mole of electron transfers. The number depends on oxidation states and the selected reaction reference.

In the oxygen balance used here, reduction of one mole O₂ to water accepts four moles electron equivalents. This is distinct from oxygen molecule count, carbon moles and energy. A consistent complete reaction equation remains the basis.

Used in these chapters · 1
Back to the term directory

Electroneutrality

Related search terms: charge balance

Electroneutrality means that positive and negative charge contributions balance within the macroscopic solution volume considered. For a homogeneous electrolyte solution this is written Σzᵢcᵢ = 0. Charge numbers zᵢ retain their signs, so calcium and chloride enter with different factors.

Charge balance supplements material balances and chemical equilibria. A supposedly complete recipe calculation with a substantial charge excess often indicates missing counterions or incorrect protonation states. This bulk-solution statement does not exclude spatial charge separation within an electrical double layer at an interface.

Foundations: Low Electrolytic Conductivity Standards

Used in these chapters · 3
Back to the term directory

Electropolishing

Related search terms: electrochemical polishing

Electropolishing is an electrochemical material-removal process in which the workpiece acts as the anode in a suitable electrolyte. Under appropriate conditions, microscopic protrusions are removed preferentially. This can improve surface topography while also removing certain near-surface contaminants. The method is used for product-contact stainless-steel surfaces, among other applications.

The result depends on initial condition, alloy and processing conditions. Deep scratches, pores and poorly executed welds do not reliably disappear through electropolishing alone. A lower measured roughness also establishes neither sterility nor complete cleanability. Geometry, crevices and accessibility remain relevant. Specifications should therefore describe the required final surface condition and appropriate verification, rather than treating the manufacturing process name itself as proof of quality.

Back to the term directory

Elution

Related search terms: elution pool, eluting

Elution carries a substance out of a chromatographic stationary phase with the mobile phase. In binding methods, appropriate changed conditions may promote release. The collected elution pool is a defined fraction of that outlet.

Pool boundaries affect quantity, purity and concentration. A broader collection window may recover more product while also collecting more impurities or liquid. Selection needs suitable analytical information and the requirements of the following step.

Foundations: Protein preparation handbook

Used in these chapters · 3
Back to the term directory

Emission factor

Related search terms: emission factor

An emission factor relates emissions to an activity, for example kg CO₂-equivalent per kWh of supplied energy. It needs origin, time reference, included substances and a clear boundary.

A direct-combustion factor is not automatically a full life-cycle factor. Electricity and heat factors are not interchangeable without matching definitions. Multiplying by consumption yields only the contribution represented by that factor.

Foundations: Product Life Cycle Accounting and Reporting Standard

Back to the term directory

Empirical biomass formula

Related search terms: Biomass formula

A simplified formula describing mean elemental ratios of a defined biomass fraction, often normalised to one carbon atom. CH₁.₈O₀.₅N₀.₂, for example, is an assumed teaching-case composition rather than a universal cell formula.

The formula converts mass into elemental amounts and supports bounded redox accounting. It must match the dry or ash-free material basis. Changes in cellular composition, storage material or retained salts can limit its applicability.

Used in these chapters · 1
Back to the term directory

Endotoxins

Related search terms: bacterial endotoxins

Endotoxins are components of the outer membrane of Gram-negative bacteria, principally lipopolysaccharides or lipooligosaccharides. They can enter process liquids during growth, membrane shedding and cell breakdown. For certain medicinal products they are critical because they can trigger fever and inflammatory responses. Biologically active amounts can also distort cell culture experiments.

Killing the bacteria does not reliably remove endotoxins already present. Ordinary sterilising filtration is likewise not general evidence of endotoxin removal. Microbial burden and endotoxin burden must therefore be considered separately. Suitable raw materials, controlled water quality and limited holding times help prevent unnecessary accumulation. Acceptance limits depend on the product, its use and the test method; a negative sterility test cannot establish compliance with an endotoxin limit.

Used in these chapters · 3
Back to the term directory

Energy balance

Related search terms: Heat balance, Energy balances

An energy balance accounts for changes in stored energy and transfers through heat, work and material streams across a stated boundary. It follows conservation of energy. Energy carried by flowing matter is commonly expressed using enthalpy; kinetic or potential contributions require justified simplification before they are omitted.

A reactor heat balance may consider biological heat release, agitation, feed temperature, evaporation and cooling. Constant culture temperature does not imply zero energy transfer: contributions may balance. Biological heat release converts chemical energy and must not be counted again if the same conversion is already fully represented in the stream enthalpies. Signs and reference states must be consistent.

Foundations: MIT: Control volume form of the conservation laws

Used in these chapters · 10
Back to the term directory

Energy dissipation rate

Energy dissipation rate describes how quickly mechanical flow energy is irreversibly converted into internal energy. Turbulence descriptions commonly express it per unit fluid mass as ε in W/kg, equivalent to m²/s³. Under suitable steady-state assumptions, P/(ρV) can estimate an average magnitude, using hydraulic power P, density ρ and liquid volume V.

That average is not equivalent to local values. Exposure near an impeller can differ substantially from conditions elsewhere in the vessel. Biological interpretation also requires considering how often cells pass through such regions. A numerically calculated dissipation rate therefore characterises a flow model first; translating it into cell damage needs additional relationships appropriate to the particular culture and its exposure history.

Back to the term directory

Enthalpy

Related search terms: specific enthalpy

Its definition is H = U + pV, with internal energy U, absolute pressure p and volume V. Per unit mass, h = u + p/ρ, where ρ is density and u is specific internal energy. Enthalpy is a thermodynamic state quantity; specific enthalpy is expressed per mass, for example in kJ/kg. Enthalpy difference between inlet and outlet often provides a useful energy-balance basis for flowing thermal processes.

A value requires an appropriate material state and reference definition. Total steam enthalpy is not automatically all useful heat at the consumer. Condensate state, other energy transfers and losses determine the relevant difference.

Foundations: Steam Consumption of Plant Items · 18.5 Heat Exchangers · 5.3 Enthalpy

Used in these chapters · 5
Back to the term directory

Enthalpy flow

Related search terms: enthalpy flow

Enthalpy flow is mass flow multiplied by specific enthalpy. Units of kg/s and kJ/kg give kJ/s or kW. A consumer commonly uses the inlet–outlet enthalpy-flow difference within its energy balance.

Enthalpy flow and transferred heat are not identical under every boundary. Work, storage and losses can contribute further terms. State streams, conditions and time assumptions explicitly.

Foundations: Steam Consumption of Plant Items · 18.5 Heat Exchangers

Back to the term directory

Enthalpy of mixing

Enthalpy of mixing is the enthalpy change on combining components under specified state conditions. Real mixtures may absorb or release heat even without consuming their main components in a simple reaction equation.

Concentrated-solution preparation can therefore produce temperatures differing from an arithmetic average of initial temperatures. A material balance is necessary but not an energy balance. Actual medium stocks require suitable properties and handling conditions.

Foundations: 5.3 Enthalpy · Animal Cell Culture Guide

Back to the term directory

Enthalpy of neutralisation

Enthalpy of neutralisation is the enthalpy change of a specified acid–base reaction under defined conditions, referenced to reacted amount or reaction equivalent.

Heat during concentrated-base dosing therefore depends on more than pump volume. Reaction path, concentration, dilution and heat removal affect local temperature. Transferring a value from another acid–base system requires a justified basis.

Foundations: 5.3 Enthalpy

Back to the term directory

Enthalpy of vaporisation

Related search terms: latent heat, latent heat of vaporisation

Enthalpy of vaporisation is the enthalpy difference between liquid and vapour for the phase change considered, commonly expressed specifically in kJ/kg. At saturation, h_fg = h_g − h_f.

Condensation can release this heat under the corresponding system boundary. Further condensate cooling is a separate contribution. One assumed constant value does not replace appropriate properties across a broad pressure range. Double counting occurs if an enthalpy difference already includes condensate cooling and that cooling is subsequently added again.

Foundations: Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam · What is Steam?

Used in these chapters · 2
Back to the term directory

Enzyme

Related search terms: Enzymes

A biological catalyst, usually a protein; some RNA molecules are also catalytic. An enzyme accelerates a reaction without being consumed stoichiometrically as a reactant.

Catalytic action does not imply unlimited stability. An enzyme may become inactive or degrade under process conditions. Enzyme mass, measured activity and actual reactor conversion are therefore distinct quantities with their own measurement and reference definitions.

Foundations: Enzyme

Used in these chapters · 14
Back to the term directory

Enzyme activity

Rate of an enzyme-catalysed conversion determined under stated assay conditions. Catalytic activity is expressed as amount converted per time; its SI unit is the katal, mol/s. Other commonly used units require an explicit assay definition.

Activity is not enzyme mass. Substrate, pH, temperature and evaluation method can influence the result. Preparations need a compatible measurement basis for comparison; high total protein does not automatically demonstrate high activity of the intended enzyme.

Foundations: The International System of Units, SI Brochure · The protein cost of metabolic fluxes: prediction from enzymatic rate laws and cost minimization

Used in these chapters · 3
Back to the term directory

Epistasis

Epistasis means that the effect of a genetic variant depends on the genetic background or on other variants. Two individually characterised changes need not produce the combined phenotype expected from their separate effects. Quantitative assessment requires the expected relationship to be defined explicitly.

This creates a practical strain-development question: does a beneficial individual change remain beneficial in the combined strain? Product formation, growth and by-products should be measured in the intended combination. An interaction in an experimental design does not, by itself, establish a particular molecular mechanism.

Foundations: NHGRI: Epistasis

Back to the term directory

Equipment maintenance

Related search terms: maintenance, equipment maintenance

Equipment maintenance covers activities intended to preserve equipment condition and limit deterioration; depending on usage, it can also include repair and broader upkeep. The agreed scope therefore needs an explicit description rather than reliance on the word alone.

A replaced pump tube or cleaned drive does not automatically demonstrate required measurement or delivery performance. Following intervention, verify affected functions according to their use. Maintenance, calibration and qualification answer different questions even when scheduled together.

Foundations: BioFlo 320 Performance Plans

Used in these chapters · 24
Back to the term directory

Equipment occupancy time

Related search terms: occupancy, occupation time

Equipment occupancy is the period during which a resource is committed to a task and unavailable for a competing task. It may include preparation, processing and restoration. The next required equipment state defines its end.

Occupancy differs from active labour and culture duration. Activities overlap only when their resources actually permit it. A complete definition prevents artificially high batch counts created by omitted supporting work.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 21
Back to the term directory

Equipment utilisation

Related search terms: utilisation, utilization

Utilisation relates occupied or used resources to explicitly defined available capacity. A time measure may divide occupied hours by available hours. Define both terms before comparison.

High local utilisation does not automatically imply high system output. A non-limiting reactor can generate additional waiting inventory. Useful reporting therefore combines utilisation, completed quantity, work in progress and requirement violations.

Foundations: Basic Concepts in Queueing, lecture8

Used in these chapters · 9
Back to the term directory

Equivalent annual cost

Related search terms: equivalent annual cost

Equivalent annual cost spreads the present value of a defined cost stream into equal annual model amounts using the capital recovery factor. Evaluation duration, discount rate and residual-value assumption are part of the result.

Comparisons of bioreactor systems with different lives must also specify replacement investments and a common service horizon. A smaller annual amount alone proves neither equal process performance nor equal failure risk. These properties require comparison before cost ranking.

Foundations: 11.3 Time Value of Money

Back to the term directory

Equivalent-circle diameter

Equivalent-circle diameter is the diameter of a circle with the same projected area as an observed object: d = 2√(A/π).

It reduces a two-dimensional image to one size descriptor. It does not establish the third dimension, volume, biomass or internal density of a pellet without additional assumptions. Measured projected area A gives d = √(4A/π). Two shapes with equal area therefore receive the same value despite different perimeters or branching. Accidentally merging two equal image objects increases calculated diameter by √2 without biological growth, making segmentation quality relevant to interpretation of size distributions.

Used in these chapters · 1
Back to the term directory

Essential amino acids

Related search terms: Essential amino-acid supply

Essential amino acids cannot be synthesised by a cell in sufficient amounts under the conditions considered and must therefore be supplied through the medium. Which amino acids are essential depends on the organism and sometimes on the particular cell line. The classification used in human nutrition cannot simply be transferred to every production organism.

Shortage of one required amino acid can restrict protein synthesis and growth even when considerable total nitrogen remains available. Conversely, excess supply does not necessarily improve productivity and can burden other metabolic pathways. Amino acids labelled non-essential may also become functionally limiting when demand is high. Medium development should therefore consider biosynthetic capacity, consumption and the manufacturing objective together.

Back to the term directory

Eulerian description

Related search terms: Eulerian perspective

The Eulerian description considers variables at fixed spatial locations. A concentration field or stationary probe provides this perspective.

The time history at one location is not identical to the history along a moving cell. Both perspectives complement assessment of spatial gradients. A stationary field means that the value at each fixed location does not change with time. A cell moving through it can nevertheless experience changing concentrations. Deriving a lifeline additionally requires motion and temporal association; a spatial mean alone does not supply that information about individual exposure.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Used in these chapters · 1
Back to the term directory

Evaporation

Related search terms: water evaporation

Evaporation is transfer of liquid to vapour at its surface, including below boiling temperature. Its rate depends on heat and mass transport and surrounding conditions.

Predominant water loss can concentrate nonvolatile medium constituents. Vessel mass loss alone does not establish water evaporation: sampling, liquid discharge and other gas flows must be considered in the same balance. A defensible attribution therefore balances medium, condensate and known inlet and outlet streams over the same time boundary.

Foundations: 11.4 Colligative Properties

Used in these chapters · 26
Back to the term directory

Event time

Time when a physical event or sample collection actually occurs. It may differ from display time, database arrival or result availability. An offline result generally belongs to its sample-collection time when reconstructing the biological trajectory.

Reconstructing a past decision instead requires knowing when the result became available. Retain both timelines. Shifting a curve without evidenced timing can create or conceal an apparent biological delay.

Used in these chapters · 6
Back to the term directory

Exon

An exon is a region of a transcript retained in the mature RNA after splicing. In protein-coding genes, exons can contain translated as well as untranslated regions. Exon and protein-coding sequence are therefore not interchangeable terms.

The distinction helps when comparing genomic sequence, RNA measurements and the protein produced. An assay covering one exon region does not automatically establish the complete product sequence or identify every transcript variant. Cell-line findings should specify the region examined and the conclusions that the measurement can support.

Foundations: NHGRI: Exon

Back to the term directory

Expanded uncertainty

Expanded uncertainty U multiplies combined standard uncertainty by a stated coverage factor: U = k·u_c. Include the factor in the result report.

Choosing k = 2 alone does not establish exactly 95% coverage. Distribution, reliability of estimated contributions and the model must support the interpretation. A process comparison also requires distinguishing shared effects from independent differences. For example, u_c = 0.30 g/L and k = 2 give U = 0.60 g/L. U is the half-width of the interval y ± U; its full width is 1.20 g/L here. This calculation alone does not establish statistical coverage probability.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 4
Back to the term directory

Experimental factor

Related search terms: Factor

An experimental factor is an influence investigated in a design, such as medium type or a coded temperature setting. It may be numerical or categorical; its levels define the conditions compared.

The intended setting is distinguished from the observed process trajectory. An agitation-speed level does not automatically specify constant oxygen transfer. Physical and biological quantities that change alongside it are part of the interpretation of the factor effect.

Foundations: Two-level full factorial designs

Used in these chapters · 32
Back to the term directory

Experimental unit

The experimental unit is the unit to which a treatment is independently assigned. Depending on the question, it may be a reactor run, vessel or separately treated sample.

Several measurements from one culture do not automatically create several independently treated units. The number of units and the design determine which process variation can be estimated. Shared inoculum, day or equipment may introduce further dependence.

Foundations: Randomized block designs

Used in these chapters · 5
Back to the term directory

Exponential distribution

The exponential distribution with positive rate λ has density λ exp(−λt) for t ≥ 0. Its mean is 1/λ. It models a waiting time with constant event rate and has a constant hazard rate.

This assumption does not automatically suit ageing or learning systems. For equipment downtime, the dependence of event likelihood on elapsed time must therefore be justified. Rate and scale are reciprocals and must not be confused in a parameter table.

Foundations: Exponential distribution

Used in these chapters · 1
Back to the term directory

Exponential feeding

Exponential feeding increases the feed according to F(t) = F₀ exp(μₛt). F₀ is the initial volumetric flow, for example in L/h; μₛ is the target specific growth rate in h⁻¹ and t is time in h. The profile aims to match increasing substrate demand as biomass grows at an approximately constant specific rate.

Design requires initial biomass, feed substrate concentration and an appropriate yield coefficient. Maintenance and changing product formation may require additional terms. A programmed exponential profile therefore does not prove that cells actually grow exponentially. Oxygen or cooling limitations require feed restriction or adaptation; otherwise substrate can accumulate despite a mathematically consistent schedule.

Back to the term directory

Exposure

Related search terms: exposure duration

Exposure here means that a person, material or biological system is subjected to a specified influence, such as heat, radiation or a substance. A meaningful description identifies the influence, intensity or concentration, time history and relevant contact route.

Equal exposure duration does not imply equal effect. Half an hour at changing temperature differs thermally from half an hour at constant temperature; a concentration spike also differs from a gradual change. An integrated exposure quantity is only as informative as its justified effect model and does not by itself establish a universal harm threshold.

Foundations: Managing risks and risk assessment at work · Ultraviolet (UV) Radiation

Used in these chapters · 47
Back to the term directory

Exposure duration

Exposure duration is time spent under a defined condition. It may mean one uninterrupted episode or accumulated time across episodes; the choice must be specified.

Equal total duration does not establish equal biological effect. Magnitude, ordering and recovery between events can also matter. With sampled data, calculated duration depends on whether values represent interval starts, ends or averages. Brief events between samples may be missed. Threshold, integration convention and time step therefore belong with the reported duration; extra displayed decimal places do not establish equally precise exposure information.

Used in these chapters · 6
Back to the term directory

Expression vector

Genetic carrier whose elements are intended to enable production of a selected RNA or protein. Target sequence and regulatory context form one construct.

Detecting the target sequence alone does not establish stable production. Actual function in the intended host and process requires separate assessment.

Foundations: Addgene

Back to the term directory

Extractables

Related search terms: extractable substances

Extractables are substances released from a material under specified test conditions, often deliberately more severe than routine use. Such studies characterise the potential release profile of bag films, tubing and seals, for example. Solvent, temperature, duration and prior sterilisation influence the substances and amounts detected. Results therefore always belong to a clearly described experimental arrangement.

Extractables are not automatically present at the same concentrations in the actual process. The data provide a starting point for assessment under realistic contact conditions. A comprehensive supplier report is useful but must match the component's material formulation, irradiation history and operating limits. Changes in formulation or processing particularly require reassessment of whether existing information remains applicable to the component in use.

Used in these chapters · 1
Back to the term directory

Extrapolation

Applying a relationship beyond the range covered by the observations used to establish it. Examples include extending a growth curve into a later culture phase or estimating uptake at μ = 0 from higher growth rates only.

The calculation may be unambiguous while biological transfer remains uncertain. A small fitting error inside the observed range does not justify unlimited extension. State range, assumptions and possible state changes with every extrapolated result.

Used in these chapters · 12
Back to the term directory

F

F distribution

The F distribution arises as the ratio of two independent chi-square variables, each divided by its degrees of freedom. It therefore has separate numerator and denominator degrees-of-freedom parameters.

In suitable linear models it supports assessment of ratios of mean squares, for example in a lack-of-fit test. This reference distribution applies only under the required model assumptions. A large ratio identifies neither a biological cause nor practical importance.

Foundations: F distribution · Testing missing or misspecified model terms

Back to the term directory

F₀ value

Related search terms: F0, equivalent sterilisation time

The F₀ value expresses a changing temperature history as an equivalent treatment time at 121.1 °C, using a z-value of 10 K. It is calculated as F₀ = ∫10^((T(t) − 121.1 °C)/10 K) dt. If time is entered in minutes, F₀ is also expressed in minutes. Temperature represents the location being assessed within the load or equipment.

F₀ is consequently a modelled quantity, not a direct measurement of sterility. Two histories with equal F₀ are equivalent only in terms of the chosen inactivation model. Air pockets, inadequate moisture contact or different organism resistance can limit that interpretation. Product damage may also differ despite identical F₀ values. The required target must therefore be justified for the actual application.

Used in these chapters · 1
Back to the term directory

Factor coding

Related search terms: Coded factors

Factor coding maps physical settings to dimensionless coordinates. For a symmetric range, x = (value − centre)/half-range is a common linear coding.

This makes coefficients easier to compare within a design. A coefficient’s numerical value nevertheless depends on the coding. To implement a candidate, coordinates are converted back to the original units using the documented centres and range widths.

Foundations: Two-level full factorial designs

Used in these chapters · 1
Back to the term directory

Factor level

Related search terms: Factor levels

A factor level is a specified value or category of an experimental factor. A two-level design uses two levels per factor; the coded values −1 and +1 are not physical units.

The distance between levels determines the interval represented by an estimated effect. Comparing two settings does not provide an arbitrarily detailed dose–response curve. Permissible ranges are justified scientifically before a numerical design is generated.

Foundations: Two-level full factorial designs

Used in these chapters · 3
Back to the term directory

Factory acceptance test (FAT)

Related search terms: factory acceptance testing

A factory acceptance test examines equipment at the manufacturer's site against agreed criteria before shipment. Relevant functions, construction features and documentation can be assessed while corrections remain comparatively straightforward. Test conditions and limitations should be explicit, for example when only simulated utility signals or substitute media are available.

FAT is an acceptance activity, not automatically a complete qualification. Properly documented results may be used later when justified and when transport and installation cannot affect the tested characteristic. Other properties require renewed or first-time testing at the operating site. A signed acceptance record should identify open points, their significance and agreed resolution. The customer's presence at the test is not a substitute for traceable evidence of the results obtained.

Used in these chapters · 3
Back to the term directory

Failover

Related search terms: failover

Failover automatically transfers operation to a standby or redundant system when the active system fails or stops functioning normally. It differs from a manually prepared restart. Actual behaviour depends on the architecture.

For bioreactor control, verify correct handling of states, data and output signals during transition. Having two computers does not establish suitable failover. Demonstrate the required function, including switching time and possible shared dependencies.

Foundations: Failover

Back to the term directory

Fed-batch culture

Fed-batch culture supplies nutrients during cultivation without a matching continuous withdrawal of culture broth. The feed may remain constant, follow a time programme or respond to measurements. For example, carbon supply can be restricted while a substantial total amount of substrate is converted over the complete run.

This approach can reduce substrate inhibition and unwanted by-product formation. It does not guarantee a low residual substrate concentration: excessive feeding can exceed uptake, oxygen supply or cooling capacity. Working volume usually increases, changing both concentrations and engineering conditions. Interpretation therefore requires records of cumulative additions and volume changes. Small analytical withdrawals do not, by themselves, turn fed-batch cultivation into continuous culture.

Used in these chapters · 20
Back to the term directory

Feedback control loop

A feedback control loop compares a measured process variable with a setpoint and changes a manipulated variable to reduce the deviation. The chain comprises measurement, controller, actuator and the affected process. Temperature control, for example, adjusts heating or cooling from the difference between measured and desired culture temperature.

Feedback responds to disturbances but requires a dependable measurement and sufficient actuator capacity. A controller cannot replace missing heating power or correct an improperly installed probe. Aggressive settings, dead time or interaction between control loops can create oscillations. Troubleshooting should therefore examine the measurement, actual actuator effect and process dynamics together rather than changing controller parameters alone.

Back to the term directory

Feedforward control

Feedforward control changes an actuator in response to a known or anticipated load before the controlled variable deviates substantially. Increasing nutrient feed may, for example, trigger a predictive adjustment of oxygen supply when the relationship between feeding and demand is sufficiently understood. The action relies on a model or an experimentally established relationship.

Feedforward can accelerate the response but does not automatically capture unmeasured disturbances or model errors. It is therefore often combined with feedback that corrects remaining deviations. A purely time-programmed feed is also specified without feedback, but need not use a current disturbance measurement. What matters is the information triggering the action and how erroneous predictions are constrained.

Back to the term directory

Fermentation and fermenter

Related search terms: Fermentor, Fermenter

In industrial biotechnology, fermentation describes a controlled biological conversion, usually performed by microorganisms. Its vessel is commonly called a fermenter or fermentor. This engineering usage includes aerobic processes: strongly aerated production of microbial enzymes can still be described as fermentation. The word alone therefore specifies neither the oxygen requirement nor the product or operating mode.

In the narrower biochemical sense, fermentation transfers electrons generated during substrate breakdown to organic acceptors, as in ethanol or lactate formation, rather than relying on respiratory electron transport. These two meanings should be kept distinct. A useful process description explicitly identifies the organism, its metabolic activity and the oxygen conditions instead of treating fermentation as a synonym for oxygen-free operation.

Used in these chapters · 25
Back to the term directory

Fibre lumen

Related search terms: lumen, fiber lumen

A hollow fibre’s lumen is its internal channel, distinct from the membrane wall and the space outside the fibres. Lumen diameter is a geometrical quantity; membrane separation threshold is a different property.

A smaller lumen can produce different velocity and pressure loss at the same individual flow. Fibre count also affects distribution of total flow. Equal hollow-fibre area therefore does not establish equal conditions inside the lumens.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems

Used in these chapters · 1
Back to the term directory

Filamentous fungi

Related search terms: Moulds, Mycelium

Filamentous fungi grow mainly as branching threads called hyphae. Together these form a mycelium, which can remain dispersed in liquid culture or organise into denser aggregates and pellets. Growth form affects broth flow and the access of nutrients and oxygen to biologically active regions. Equal dry biomass concentrations consequently need not produce equal process behaviour.

These organisms are used to manufacture enzymes, organic acids and specialised metabolites. Their morphology results from interactions between strain, inoculum, medium and mechanical environment. Compact pellets can make a culture easier to handle but may develop poorly supplied interiors. Dispersed mycelium can instead raise viscosity. There is therefore no universally preferable morphology; its value must be judged against the specific production objective.

Used in these chapters · 3
Back to the term directory

Filter integrity

Related search terms: filter integrity testing

Filter integrity describes the undamaged, correctly assembled condition of a filter system in relation to its intended retention function. A suitable non-destructive test may use gas transport through a wetted membrane or a defined pressure response. Acceptance limits must match the filter and test conditions and have an established relationship with the relevant retention performance.

A passing test does not by itself show that the filtered product is sterile. Product compatibility, process limits and the downstream barrier must also be suitable. Incomplete wetting, temperature changes and leaks in the test arrangement can distort results. An unexpected finding therefore requires consideration of the complete system, not just the membrane. Repeating a test without justification until it passes does not provide reliable integrity evidence.

Back to the term directory

First-order reaction

Related search terms: first-order kinetics

For a simple first-order reaction, consumption rate is proportional to the concentration considered: r = kC. At constant k and volume, without other inflows or outflows, C(t) = C₀ exp(−kt). The rate constant then has the dimension of inverse time.

This compendium uses the kinetics as an explicitly simplified comparison between residence-time models, not as a universal law for biological uptake or growth. An exponential measured trace does not itself prove these reaction kinetics because transport and sensor dynamics can produce similar shapes. Measurement boundary and alternative dynamic processes must therefore be examined before assigning a mechanism.

Foundations: Integrated Rate Laws

Used in these chapters · 1
Back to the term directory

First-order system

Related search terms: first order system

A linear first-order system can be represented in a simple form by τ dy/dt + y = K u. Here τ is the time constant and K the steady-state gain. Following an input step, these assumptions give an exponential approach to the new final value; approximately 63.2 percent of the complete change has occurred after one time constant.

The model can approximate a sensor or a well-mixed store. Two delays in series do not, in general, reduce to one first-order delay. A good curve fit alone also cannot establish which delay belongs to the process and which to the measurement arrangement.

Foundations: 18.3 Transient Heat Transfer (Convective Cooling or Heating)

Used in these chapters · 1
Back to the term directory

Fixed cost

Related search terms: fixed costs

Fixed costs initially remain unchanged with the selected volume change within a defined time and activity range. Classification depends on the decision. Equipment committed today may create alterable costs in the longer term.

Lower output spreads the same fixed costs over fewer units. A local time saving does not automatically reduce them. Examine whether expenditure can actually be avoided or only its accounting allocation changes.

Foundations: 10.1 Identify Relevant Information for Decision-Making

Used in these chapters · 2
Back to the term directory

Flash steam

Related search terms: flashing

Flash steam forms when hot condensate partly vaporises during pressure reduction. Its existing enthalpy may exceed that of liquid at the lower pressure, transferring part of the mass to vapour.

Visible steam in a return therefore does not automatically establish live-steam leakage through a trap. Quantification needs appropriate inlet and outlet states and a consistent energy balance. For ideal adiabatic flashing, vapour fraction can be calculated from inlet enthalpy and the two saturation enthalpies at outlet pressure.

Foundations: What is Steam?

Used in these chapters · 1
Back to the term directory

Flat-panel photobioreactor

Related search terms: Flat-plate photobioreactor

A flat-panel photobioreactor holds a culture in a shallow, transparent chamber between broad walls. The small liquid depth shortens the optical path through the suspension. Gas bubbles or another circulation mechanism move cells between differently illuminated regions and support dissolved-gas exchange.

Panel spacing, orientation, mutual shading and heat removal matter when designing the system. A thinner culture layer does not increase useful productivity without limit: illumination, cell concentration and circulation must work together. Adding panel area may preserve the optical environment better than increasing the distance between walls during scale-up. The geometric wall area must also be distinguished from the area receiving effective illumination, particularly in closely packed installations.

Used in these chapters · 1
Back to the term directory

Flow bypass

Related search terms: bypass

A flow bypass is a route by which part of a stream shortens or avoids an intended contact or residence region. A residence-time experiment may show it as an early exiting fraction. Bypass fraction and residence duration are separate quantities; the mean alone does not describe the short pathway completely.

An early response establishes bypass only after injection behaviour, time origin and measurement dynamics have been assessed. Process consequences additionally depend on the reaction or exposure missed along that route. The term is not synonymous with channeling in a bed, which describes a particular spatial maldistribution and may be one possible cause.

Foundations: Chapter 16: Distributions of Residence Times for Chemical Reactors

Used in these chapters · 1
Back to the term directory

Flow channelling

Related search terms: channeling

Flow channelling denotes preferred pathways that leave parts of a bed or reaction space less effectively contacted. Uneven packing, growth or changing resistance can contribute.

An early tracer response is a possible indication, not unique proof of the spatial pattern. Identifying a cause needs additional information on inlet distribution, packing and deposits. Total flow can appear normal while parts of the bed receive little exchange. Tracer experiments and spatial measurements can provide useful evidence. An early tracer response alone is not conclusive until injection behaviour, measurement delay and other possible short pathways have been examined for the same system boundary.

Foundations: Chapter 16: Distributions of Residence Times for Chemical Reactors

Back to the term directory

Fluidisation

Related search terms: fluidization

Fluidisation is expansion and movement of a particle bed by a flowing fluid supporting a substantial part of effective particle weight. The fluid may be liquid or gas.

Distinguish this state from flow through a fixed bed and from complete particle entrainment. Gas–solid correlations cannot be transferred uncritically to liquid beds containing biomass. The transition changes void fraction, particle movement and exchange. It does not guarantee perfect uniformity; bypass, aggregation or entrainment can remain relevant. For biological carriers, growth may change density, size or surface properties, shifting the original fluidisation condition and limiting transfer of measurements from clean particles.

Foundations: Fluidized Bed Reactors, Professional Reference Shelf

Used in these chapters · 1
Back to the term directory

Fluidised-bed bioreactor

A fluidised-bed bioreactor suspends solid carrier particles in an expanded, moving bed using upward flow. Fluid drag counteracts the effective weight of the particles. Within a suitable velocity range, the carriers remain in the reactor while liquid flows around them and transports material to attached or entrapped cells.

Unlike a packed bed, individual particles can change position, altering contact and flow paths. Insufficient flow allows settling, whereas excessive flow may carry particles out of the vessel. The operating window depends on particle size, density, biomass growth and liquid properties. Greater bed expansion alone does not prove better supply or higher productivity; it can also change particle interactions and the distribution of biomass.

Used in these chapters · 1
Back to the term directory

Fluorescence measurement

Fluorescence measurement detects light emitted by suitable molecules after optical excitation. Selecting excitation and emission wavelengths defines the measurement channel. In bioprocesses, natural fluorophores, introduced reporters or specific dyes can provide information about cells, metabolic conditions or particular target molecules.

Signal intensity does not depend solely on analyte quantity. pH, temperature, oxygen, optical attenuation and quenching by other molecules can change it. Signals from different fluorophores may also overlap. High sensitivity therefore does not replace selectivity assessment. Falling intensity may reflect less target material, a changed environment or photobleaching; interpretation needs appropriate controls and normalisation suited to the actual scientific question.

Used in these chapters · 1
Back to the term directory

Foam

Liquid foam consists of gas bubbles separated by liquid films and interconnected liquid regions. It can accumulate above the bulk liquid surface. Formation and lifetime depend on gas supply, surface-active constituents, drainage from the films, and bubble coalescence or rupture.

Foam height is therefore not a direct measure of gas holdup in the underlying culture liquid. Two media can show different foam stability at the same aeration rate. Diagnosis should distinguish formation, decay, liquid carryover and wetting of the exhaust path; a foam sensor reports only the local situation accessible to its measurement principle.

Foundations: 11.5 Colloids

Used in these chapters · 17
Back to the term directory

Foam sensor

A foam sensor detects whether foam reaches a defined height or sensing zone. Conductivity-based probes, for example, respond when conductive foam establishes an electrical path between the probe and a reference point. Other designs detect changes in capacitive or optical properties. The signal can trigger a timed antifoam addition or another corrective action.

The sensor does not automatically measure total foam volume or stability. Adhering liquid and deposits can cause persistent detection, while poorly conductive foam may be missed. Suitable positioning, switching delays and limited dosing prevent unnecessary additions. Because antifoam can affect mass transfer and downstream processing, the actual cumulative quantity should be recorded.

Back to the term directory

Forecast

Related search terms: forecast, market forecast

A forecast describes future development using data, assumptions and a method. It differs from an already observed quantity. Publication date, forecast period and model assumptions govern interpretation.

Bioreactor-market forecasts can differ because of boundaries or price assumptions. Repeating the same number later does not turn it into a new observation. Decision-making requires examination and revision of assumptions as circumstances change.

Used in these chapters · 6
Back to the term directory

Fourier number

The Fourier number Fo = αt/L_c² is dimensionless conduction time using thermal diffusivity α and characteristic length L_c. It relates process duration to internal thermal relaxation.

Equal elapsed time does not imply equal Fourier number for different geometries or materials. A temperature history additionally requires initial and boundary conditions. The number is unrelated to calling a signal-processing Fourier transform an equivalent thermal model.

Foundations: 1.6 Mechanisms of Heat Transfer

Back to the term directory

Frameshift mutation

A frameshift mutation occurs within a coding sequence when insertion or deletion of bases changes the downstream triplet pattern. A typical cause is a length change that is not a multiple of three. The following amino-acid sequence may change and a premature termination signal may arise.

Assessing a production sequence requires the position, affected region and actual transcript or protein consequence. A sequence change outside the translated region is not a frameshift merely because of its length. Loss of function may be plausible, but the relevant product or cellular property needs appropriate investigation.

Foundations: NHGRI: Frameshift mutation

Back to the term directory

Frequency response

Frequency response describes how gain and phase shift depend on sinusoidal input frequency in a linear time-invariant system.

It helps assess which process fluctuations a measurement chain can resolve adequately. Good static calibration does not demonstrate sufficiently fast dynamic response. A sinusoidal input can appear attenuated and shifted in the steady periodic output. For a normalised first-order lag, the amplitude ratio is 1/√[1 + (ωτ)²]. Here ω is angular frequency in rad/s; frequency expressed in Hz must first be multiplied by 2π.

Foundations: Lesson 4: Two Tanks in Series

Back to the term directory

Froude number

A common Froude number is Fr = U/√(gL), comparing velocity with a gravity-based scale. Some disciplines instead use its square.

For comparisons involving waves or free surfaces, state the definition and length scale. Fr and Fr² cannot be inserted interchangeably into a correlation. Impeller correlations may use N²d/g with rotational speed N in s⁻¹. This is not simply the numerical value of U/√(gL) without defining U and L. Before transferring a correlation, check its formula, reference quantities and the experimental geometry from which it was established.

Foundations: A simulation modeling framework for fluid motion and transport in a rocking bioreactor

Back to the term directory

Frozen-rotor approach

A frozen-rotor approach uses a fixed relative position between rotating and stationary geometry regions in a simplified flow calculation. Rotation enters through the reference-frame formulation.

It reduces computational cost but does not automatically resolve every temporal interaction between impeller and internals. Adequacy depends on the target quantity. A fixed impeller position relative to internals cannot follow their instantaneous interaction through a complete rotation. A local time-dependent quantity may therefore require another calculation. Suitability should be tested against that quantity rather than judged solely from agreement in overall power consumption or another global summary.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Back to the term directory

Functional unit

Related search terms: functional unit

The functional unit quantifies the service used as the reference for an environmental assessment. For a bioprocess it may be a specified amount of suitable product at a stated handover point. Quality and function belong to the task.

A culture litre is not automatically equivalent to usable product mass. Different recovery can change ranking per service. Choose the functional unit before comparison rather than afterwards to favour an option.

Foundations: Life Cycle Assessment & EF methods · Product Environmental Footprint method

Used in these chapters · 2
Back to the term directory

Fungal pellet

Related search terms: pellet

A fungal pellet is a coherent aggregate of filamentous biomass in a culture. Size, shape, density and internal structure can vary substantially.

Smaller diameter does not establish higher productivity. Transport assessment includes internal consumption, effective diffusion and supply at the surface. An area-equivalent diameter initially describes the projection, not internal porosity or active biomass. Diffusion and local uptake can generate internal concentration differences. These observations do not establish a universal favourable pellet size; transport, organism and measurement definition must be considered together for the specific process question.

Foundations: A Library of Aspergillus niger Chassis Strains for Morphology Engineering

Used in these chapters · 4
Back to the term directory

G

Gamma distribution

The gamma distribution is a continuous family for positive quantities. With shape k and scale θ, its mean is kθ and variance kθ². Some programs instead use the rate parameter 1/θ.

It may be assessed as a model for certain positive waiting times or asymmetric measurements. Parameter convention must be clear before comparing analyses. Positive data alone are insufficient evidence that a gamma distribution suits the particular process question.

Foundations: Gamma distribution

Back to the term directory

Gas dispersion

Gas dispersion is the break-up and spatial distribution of a gas phase as bubbles within a liquid. It creates interfacial area and influences how long gas remains in contact with the culture. The sparger establishes initial conditions, after which impellers, buoyancy and liquid motion shape the evolving bubble distribution.

Effective dispersion therefore involves more than visible bubbles or a uniformly moving surface. Gas may rise through a narrow region while other areas receive little exchange. Assessment should combine bubble sizes, gas holdup, distribution and actual mass transfer. Stronger break-up can also change mechanical exposure and foam behaviour. The best setting follows from the complete process duty, rather than the smallest achievable individual bubble.

Used in these chapters · 3
Back to the term directory

Gas holdup

Related search terms: Gas hold-up, Void fraction

Gas holdup is the volume fraction occupied by gas bubbles in a gas–liquid dispersion. With gas volume VG and liquid volume VL, a common definition is εG = VG/(VG + VL). This dimensionless fraction differs from the ratio of gas volume to liquid volume.

Increasing gas holdup raises the dispersion level at unchanged liquid inventory and affects average density, circulation and available headspace. It does not directly measure interfacial area or oxygen supply: the same gas volume may occur as a few large bubbles or many small ones. A reported value should also identify whether it is local or averaged across a defined region of the vessel.

Used in these chapters · 5
Back to the term directory

Gas reference state

Related search terms: Gas reference conditions

A gas reference state specifies pressure, temperature and, where relevant, moisture basis for reporting a gas amount or volumetric flow. Labels such as normal litre or standard litre are insufficient when the underlying convention is unknown. Different reference temperatures yield different reference volumes for the same amount of substance.

For the same approximately ideal gas, V₂/V₁ = (T₂/T₁)·(p₁/p₂), using kelvin temperatures and absolute pressures. At unchanged pressure, 10 L at 273.15 K corresponds to about 10.73 L at 293.15 K. No additional gas has been produced. Before an off-gas balance, inlet flow, outlet flow and composition measurements must use compatible states and a common moisture basis.

Foundations: MIT: Changing the state of a system with heat and work

Used in these chapters · 5
Back to the term directory

Gauge and relative pressure

Related search terms: Gauge pressure, Relative pressure

Relative pressure is a pressure difference against a stated reference. For a conventional gauge-pressure instrument, the reference is the surroundings. A positive reading then indicates pressure above ambient, while a negative reading indicates pressure below it. Absolute pressure equals relative pressure plus the reference pressure.

A reactor and its cooling circuit may both operate above ambient while still imposing a pressure difference across their separating wall. That difference must not be confused with either individual reading. Sensor type, reference connection and installation position should be recorded. A differential-pressure sensor connected between two lines does not automatically measure either line’s gauge pressure relative to the atmosphere.

Foundations: OpenStax College Physics 2e: Gauge pressure and absolute pressure

Used in these chapters · 9
Back to the term directory

Gene

Related search terms: Genes

A genetic region whose information contributes to a functional RNA product and, where applicable, a translated protein. In cells this information is carried by DNA, and gene boundaries also depend on biological context.

Not every gene codes for protein, and a present sequence does not guarantee a particular expression level. Sequence, regulation and actual function should therefore remain distinct in production-strain records. A generic gene name does not identify the precise construct examined.

Foundations: Gene

Used in these chapters · 2
Back to the term directory

Geometric distribution

The geometric distribution describes the number of independent trials until the first success when success probability p remains constant. In this convention support starts at one and P(K = k) = (1 − p)^(k − 1)·p.

Another convention counts preceding failures only and starts at zero. This difference matters for software and expectations. With changing conditions or deliberately adapted subsequent experiments, constant p is not automatically plausible, so the simple model must be restricted.

Foundations: scipy.stats.geom

Back to the term directory

Geometric similarity

Geometric similarity means corresponding lengths in different reactors have the same ratios. Relevant dimensions include vessel height and diameter, impeller diameter, impeller spacing and the sizes and positions of important internals. If all lengths increase by a factor λ, areas increase by λ² and volumes by λ³.

This simple geometry already explains why heat-transfer area per culture volume decreases during proportional enlargement. Equal shape also does not ensure dynamic similarity: speed, gas flow and material properties additionally determine flow. Connections that are not scaled can create local differences. Geometric similarity is therefore a useful foundation for comparison, rather than sufficient evidence of equal supply, mixing time or biological performance.

Used in these chapters · 2
Back to the term directory

Glass bioreactor

A glass bioreactor has a culture vessel made predominantly from suitable glass, commonly borosilicate glass. Transparency allows direct observation of liquid level, bubbles, foam and broad circulation patterns. Single-wall and jacketed vessels provide different arrangements for heat transfer and require appropriate supports and connections.

The material name alone does not establish acceptable pressure, temperature changes or mechanical loads. These depend on the specific construction and its documented limits. Visible liquid motion also does not quantify mixing performance. A comparison with a metal vessel must consider geometry, internals, heat-transfer area and the actual working-volume range, alongside vessel capacity and impeller speed. A transparent wall is useful access to observations, rather than proof of uniform conditions.

Back to the term directory

Glycolysis

Related search terms: Embden–Meyerhof–Parnas pathway, EMP pathway

Classical glycolysis converts glucose into pyruvate through a sequence of enzyme-catalysed reactions. It generates directly usable ATP and the reducing equivalent NADH, while several intermediates also support biosynthesis. The pathway itself does not require molecular oxygen. Continued operation nevertheless requires regeneration of NAD⁺ from NADH.

How cells regenerate this carrier and process pyruvate depends on their metabolic state. Respiration, lactate formation and alcoholic fermentation produce different energy yields and by-products. High glycolytic activity therefore establishes neither oxygen shortage nor complete sugar oxidation. Furthermore, not every microorganism relies exclusively on the classical pathway. Alternative routes change the balance and need to be considered for the particular production organism.

Back to the term directory

Glycosylation

In biological contexts, enzymatic covalent attachment of sugar residues to suitable molecules such as proteins or lipids. Different occupied sites and glycan structures on a protein can produce distinct glycoforms.

This is a product-structure attribute rather than merely a concentration. Unchanged amino-acid sequence does not guarantee an identical glycosylation pattern. Nonenzymatic glycation is distinct and should not be used as a synonym.

Foundations: Glossary of glycoscience terms · Cellular organization of glycosylation

Used in these chapters · 1
Back to the term directory

Good manufacturing practice (GMP)

Related search terms: GMP

Good manufacturing practice comprises requirements and principles intended to ensure reliable production of suitable quality within a regulated manufacturing context. For medicinal products, GMP combines appropriate facilities, trained personnel, traceable documentation and controlled processes. Quality is therefore addressed during process design and execution rather than relying solely on a final product test.

A bioreactor is not “GMP compliant” for every application simply because of its construction. Its intended use, supporting evidence and the operator's quality system are decisive. Equally, not every university cultivation experiment automatically has the same pharmaceutical obligations. Applicable rules depend on the product, activity and jurisdiction. Technically useful principles can still be applied outside formal GMP operations, with an appropriate and clearly defined scope.

Used in these chapters · 9
Back to the term directory

Gradient of a function

Related search terms: Mathematical gradient

The gradient of a differentiable scalar function is the vector of its first partial derivatives. It describes local sensitivity to individual variables in the chosen coordinates.

For a response surface it shows how the predicted response changes under small factor changes. The direction of steepest increase depends on scaling and the chosen distance measure. A zero gradient alone does not prove a maximum and must be distinguished conceptually from a spatial concentration gradient.

Back to the term directory

Gravimetric feed control

Related search terms: gravimetric feeding, balance feedback

Gravimetric feed control uses mass measurement to quantify or regulate additions, often through the mass change of a feed reservoir. It differs from estimating volumetric flow solely from pump speed and calibration.

For bioreactors, consider measurement location, timing and other inflows or outflows. Reservoir mass loss does not under every condition equal simultaneous arrival in the reactor. Line inventory, delay or leakage can change the relationship and need consideration in the system model.

Foundations: xCUBIO benchtop configuration

Used in these chapters · 1
Back to the term directory

Greenhouse gas (GHG)

Related search terms: GHG, greenhouse gases

Greenhouse gases interact with thermal radiation and contribute to the greenhouse effect. A climate inventory explicitly states included gases and origins. Direct CO₂ measurement therefore does not automatically cover every product-related greenhouse contribution.

Product accounting may include raw materials, manufacturing, transport, use and end treatment. The GHG Protocol product method addresses a different level from a company-only inventory. Scope, allocation and assessment factors must match the report.

Foundations: Product Life Cycle Accounting and Reporting Standard

Used in these chapters · 1
Back to the term directory

Growth factors

Related search terms: Cellular growth factors

Growth factors are substances that enable or regulate growth and other cellular functions. In animal cell culture, the term frequently refers to signalling proteins that bind receptors and influence division, survival or differentiation. Microbiology uses a broader meaning that can include required organic compounds, such as vitamins, which an organism cannot synthesise adequately.

The biological context should therefore make the intended meaning clear. Increasing growth-factor supply does not increase cell numbers indefinitely: receptor responses can saturate and other resources remain limited. A signal can also change cell identity or function. In production, the relevant question is whether an addition merely raises cell numbers or also preserves the biological characteristics required for the product.

Used in these chapters · 2
Back to the term directory

Growth phases

Related search terms: Lag phase, Exponential phase, Stationary phase, Decline phase

A culture of limited duration often passes through adaptation, rapid proliferation, a stationary period and eventual decline of the viable population. These intervals are described as growth phases. During adaptation, cells may adjust their machinery to a new medium; during exponential proliferation, an appropriate biomass measure increases in proportion to its current value.

The phases do not form a fixed timetable. Their duration depends on inoculum, supply and culture conditions, and transitions can overlap. A stationary total cell count also does not mean that every cell is resting: division and death may occur simultaneously. Product formation need not follow the growth curve either. Process decisions should therefore address the physiological cause of a transition rather than relying only on its label.

Used in these chapters · 4
Back to the term directory

Growth-associated yield

A model parameter relating new biomass to substrate demand assigned specifically to growth. In qS = μ/Y_g + m, Y_g is the inverse slope of an appropriate qS-versus-μ relationship.

Observed overall yield μ/qS additionally includes the m term and can therefore be lower. The quantities assign consumption differently. Product formation, cell loss and changed biomass basis can limit interpretation of the estimated growth-associated yield.

Foundations: Setting up and modelling of overflowing fed-batch cultures of Bacillus subtilis for the production and continuous removal of lipopeptides

Used in these chapters · 3
Back to the term directory

Gumbel distribution

Related search terms: Extreme value type I distribution

The Gumbel distribution is an extreme-value distribution with location and positive scale parameters. Separate forms describe maxima and minima, and the direction must be specified.

Under suitable extreme-value assumptions it may be considered for block maxima or minima. One culture’s peak value is insufficient either to fit or justify this model. Block length, dependence and selection of extremes determine what conclusions are defensible.

Foundations: Extreme value type I distribution

Back to the term directory

H

Harvest

Harvest is the controlled removal of the desired biological material or product from cultivation. Secreted protein production often targets a cell-depleted supernatant, whereas intracellular products or cell therapies require the cells themselves. Harvest may occur at the end of a batch, repeatedly, or continuously.

Timing and transfer affect both recovery and quality. A high reactor titre offers limited benefit if the product degrades during holding or initial separation. Hold time, temperature, shear exposure and suitable collection vessels therefore belong in the harvest strategy. Harvest does not mean complete purification: clarification, cell disruption and further downstream operations may follow, each introducing additional recovery losses.

Used in these chapters · 43
Back to the term directory

Hazard

Related search terms: hazards

A hazard is a potential source of harm, such as a hot surface, stored pressure or a biological agent. Its description identifies how harm could occur. It is distinct from risk assessment, which also considers likelihood and potential consequences.

A bioreactor equipment or substance list alone is therefore insufficient. The same closed vessel can present different hazards during operation, sampling or opening for maintenance. Suitable controls relate to the actual state and people affected; simply naming a hazard does not constitute a complete risk assessment.

Foundations: Managing risks and risk assessment at work

Used in these chapters · 5
Back to the term directory

Hazard rate

Related search terms: Failure rate, Conditional failure rate

The hazard rate h(t) is the instantaneous event rate conditional on the event not having occurred before time t. For a continuous event time with density f(t) and cumulative distribution F(t), h(t) = f(t)/(1 − F(t)) wherever F(t) is below one. Its unit is inverse time.

A rate is not a probability and may exceed one per time unit. In reliability analysis the event can be a first failure. Constant positive hazard rate gives an exponential waiting-time distribution. This statistical concept differs from a safety hazard, which denotes a potential source of harm.

Foundations: NIST/SEMATECH: Failure (or hazard) rate

Back to the term directory

Headspace

Headspace is the gas-filled region above the culture liquid. It receives bubbles leaving the liquid, allows gas to exit and provides room for liquid-level changes or foam. In a surface-aerated system, its gas composition also directly affects supply through the exposed liquid surface.

Usable headspace depends on the actual liquid level, including expansion caused by dispersed gas, rather than simply the unaerated fill volume. Too little reserve can allow liquid or foam to reach the gas outlet. Conversely, a large headspace does not automatically improve oxygen transfer because interfacial area and surface renewal may still limit exchange. Headspace volume and suitable gas throughput should therefore be assessed together with liquid-side behaviour.

Used in these chapters · 16
Back to the term directory

Heat distribution study

Related search terms: heat distribution, distribution study

A heat distribution study examines spatial temperature conditions within a defined steriliser or equipment system. Locations and time histories are compared to identify non-uniform conditions and suitable monitoring positions. An empty-chamber study examines distribution without the load that will subsequently be treated.

This does not replace a heat penetration study of the actual load. A uniformly hot surrounding space may still contain a more slowly warming filter element or densely packed item. Measurement location, configuration, calibration and the rationale for the operating states examined consequently belong in the evidence.

Foundations: Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 1
Back to the term directory

Heat exchanger

Related search terms: heat exchanger

A heat exchanger transfers heat between fluids or thermal regions. In indirect exchange, a wall separates material streams. Duty depends on area, transfer coefficients, wall and local temperature differences.

Sufficient coolant flow is only a necessary quantity condition. Achieving required heat transfer also needs suitable thermal sizing. Supply, return and actual flow conditions are therefore checked together with process state.

Foundations: 18.5 Heat Exchangers

Used in these chapters · 5
Back to the term directory

Heat flow rate

Related search terms: Heat transfer rate

Heat flow rate is energy transferred per unit time because of a temperature difference. It is expressed in watts, with 1 W equal to one joule per second. Energy in kWh and power in kW are different quantities. Integrating power over time gives the energy transferred.

Removing heat from a culture medium at a constant 6 kW for ten minutes removes 1 kWh, or 3.6 MJ. This does not determine the temperature change without the mass, heat capacity and simultaneous heat-generation terms. Heating and cooling contributions require a consistent sign convention. Electrical motor power is also not automatically a measured heat flow through the reactor wall merely because both quantities use watts.

Foundations: MIT: Changing the state of a system with heat and work

Used in these chapters · 2
Back to the term directory

Heat penetration

Related search terms: penetration study

Heat penetration describes heating over time inside the material or load item being treated. It differs from heat distribution in the surrounding chamber or steam space.

Uniform chamber conditions therefore do not establish the same temperature history inside a filled bottle. Evidence requires measurement location, article, fill and load arrangement matching the intended application and described reproducibly. A small filled vessel and a solid component may have different internal temperature histories despite the same surrounding temperature history.

Foundations: Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 2
Back to the term directory

Heat recovery

Related search terms: heat recovery

Heat recovery reuses an otherwise rejected heat flow for a suitable heat sink. Usable power depends on temperature difference, heat transfer and temporal overlap between source and demand, among other factors.

Two hours of waste heat do not automatically help a later heating step without storage or another transfer arrangement. Campaign design therefore compares time profiles and achievable temperatures. Annual energy alone does not determine usable recovery.

Foundations: Improving Steam System Performance: A Sourcebook for Industry

Used in these chapters · 3
Back to the term directory

Heat transfer

Heat transfer is energy transport caused by a temperature difference. In a bioreactor, heat can pass through the vessel wall between culture and temperature-conditioning fluid, while motion and conduction distribute energy within each fluid. Biological heat release and mechanical power dissipation can simultaneously act as heat sources inside the culture chamber.

Required cooling duty therefore depends on all heat sources, losses and changing conditions, rather than the target temperature alone. A simplified steady-state estimate often uses Q̇ = U · A · ΔT, with heat flow Q̇ in W, area A in m² and an appropriate mean temperature difference ΔT in K. A powerful external unit cannot indefinitely compensate for insufficient transfer area or poor internal circulation.

Used in these chapters · 17
Back to the term directory

Height-to-diameter ratio

Related search terms: Aspect ratio, H/T

The height-to-diameter ratio describes the slenderness of a vessel or its liquid fill. Hydrodynamic comparisons often divide liquid height H by internal tank diameter T; H/T is dimensionless. It must be stated if total vessel height is used instead, because different fill levels can otherwise appear geometrically equivalent.

The ratio affects circulation paths, possible impeller stages, bubble travel and the hydrostatic pressure profile. A taller, narrower vessel does not automatically provide better supply: long distances between vertical regions can create additional mixing demands. H/T alone also does not establish geometric similarity. Impeller diameter, spacing, baffles and bottom shape must be characterised relative to vessel dimensions when assessing whether two designs are comparable.

Used in these chapters · 2
Back to the term directory

HEK cells

Related search terms: HEK, HEK293, HEK-293, HEK cell line

In biotechnology, usually cells of the human HEK293 lineage or its derivatives. The original 293 line was established from embryonic kidney tissue and transformed with adenovirus DNA. The abbreviation does not uniquely identify every derivative in current use.

Process and bank records should specify exact line, derivative, origin and culture form. One HEK293 derivative is not automatically identical to another or usable under the same conditions. Properties of a particular collection line cannot be generalised to the entire family.

Foundations: 293 [HEK-293], CRL-1573

Used in these chapters · 1
Back to the term directory

Henderson–Hasselbalch relationship

Related search terms: Henderson–Hasselbalch, Henderson-Hasselbalch

This relationship connects pH, pKₐ and the activity ratio of a conjugate acid–base pair: pH = pKₐ + log₁₀(a_base/a_acid). A concentration form needs suitable approximations or consistently determined apparent parameters.

After addition, determine changed inventories before applying the equation. It does not replace complete charge and component balances for a complex medium or justify arithmetic averaging of different pH values.

Foundations: 14.6 Buffers

Used in these chapters · 1
Back to the term directory

Henry’s law

Henry’s law relates the equilibrium concentration of a dilute dissolved gas to its partial pressure above the liquid. One convention is c* = Hcp · p. If c* is in mol/m³ and p in Pa, Hcp has units of mol/(m³·Pa). Other tables use inverse or differently normalised constants, so values cannot be exchanged without checking the definition.

The relation describes equilibrium, rather than how quickly equilibrium is reached. Temperature, liquid composition and gas identity affect the appropriate constant. For chemically reacting gases, physically dissolved gas must be distinguished from the total chemically bound forms. Higher gas pressure alone therefore does not demonstrate adequate instantaneous supply to a consuming culture.

Back to the term directory

Herschel–Bulkley model

The Herschel–Bulkley model adds a yield stress to a power law. In the flowing regime, a common scalar form is τ = τ₀ + K·γ̇ⁿ for positive shear rate.

An extra parameter can improve a fit without establishing a physical yield stress. Interpretation requires measurements over the relevant stress range. For positive shear above yielding, a common form is τ = τ₀ + Kγ̇ⁿ. The additional parameter also increases the information required for fitting. Measurements confined to a narrow high-shear range can constrain yield stress poorly even when the fitted curve agrees closely within that range.

Foundations: Herschel-Bulkley rheology from lattice kinetic theory of soft-glassy materials

Used in these chapters · 1
Back to the term directory

Hessian

Related search terms: Hessian matrix

The Hessian contains the second partial derivatives of a scalar function with respect to its variables. For a twice continuously differentiable function it is symmetric and describes local curvature.

At a stationary point, negative definiteness is sufficient for a strict local maximum and positive definiteness for a strict local minimum. An indefinite matrix indicates a saddle point; semidefinite cases require more than this test. Process constraints must additionally be considered.

Used in these chapters · 1
Back to the term directory

Heteroscedasticity

Related search terms: Heteroskedasticity

Heteroscedasticity means that error variance is not constant across the data region considered. Homoscedasticity denotes constant error variance.

Process data may, for example, vary more at high concentration than at low concentration. Residual plots help investigate this structure. Weighting or transformation requires a justified assumption; unexamined constant-variance formulas can yield misleading intervals.

Foundations: How can I tell if a model fits my data?

Back to the term directory

High-performance liquid chromatography

Related search terms: HPLC

High-performance liquid chromatography, or HPLC, separates dissolved sample components through different interactions with a stationary phase and a flowing liquid. Separated compounds reach a suitable detector at different times. The chromatogram provides identity-related information and, with appropriate calibration, concentrations.

Bioprocess applications include analysis of substrates, organic acids and product components. The name HPLC alone does not specify which substances are measured reliably: column, mobile phase, detector and sample preparation define the method. Identical retention times do not always establish identical compounds, and overlapping peaks can distort quantification. Filtration, dilution and possible preparation losses must be included in result calculations and assessment of method suitability.

Back to the term directory

Histone

Histones are proteins involved in organising DNA within eukaryotic chromatin. Several histones form the core of a nucleosome around which DNA is wrapped. They contribute to spatial organisation, and their states can also be associated with regulation of gene expression.

In a production cell line, a change in DNA packaging cannot be diagnosed from product titre alone. Sequence stability, expression state and measured production are distinct levels of evidence. The term is useful when reading cell-line and stability studies; it does not describe a directly adjustable equipment parameter.

Foundations: NHGRI: Histone

Back to the term directory

Hollow-fibre membrane

Related search terms: hollow fibre, hollow fiber, hollow fibers

A hollow-fibre membrane is a thin tubular membrane containing an internal channel. Many fibres may form a module. Depending on construction, liquid travels along the inside or outside and can pass through the membrane wall.

Internal diameter, length, fibre count and flow arrangement affect inventory, pressure loss and exposure. Total installed area alone therefore does not describe hydraulic or biological duty. Specify actual geometry and which side is used when comparing modules.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems · XCell ATF Systems

Used in these chapters · 1
Back to the term directory

Human-machine interface

Related search terms: HMI, operator interface

A human-machine interface, or HMI, comprises hardware or software through which operators observe a technical process and interact with its controller. It may include control panels, buttons, status indicators and graphical process displays. Depending on its implementation, it can display measurements and alarms or permit authorised changes to setpoints.

For a bioreactor, distinguish the operator interface, control functions and process-data storage when assessing the system. A displayed value alone establishes neither its freshness nor complete recording. Procurement and operation should therefore specify user permissions, units, timing, confirmation of entries and behaviour during loss of communication.

Foundations: SP 800-82 Rev. 3 publication page

Used in these chapters · 1
Back to the term directory

Hybrid model

A hybrid model combines scientifically motivated submodels with relationships estimated from data. A material balance may, for example, be retained while part of a reaction rate is inferred from measurements.

The combination must treat units, interfaces and shared parameters consistently. A learned submodel can still fail outside its data basis. The mechanistic component therefore does not automatically make every overall prediction plausible or transferable; both parts are assessed together.

Foundations: Digital Twins for Advanced Manufacturing

Used in these chapters · 1
Back to the term directory

Hydrate

Related search terms: hydrates, hydrate form, water of crystallisation, heptahydrate

A hydrate includes water within its specified solid chemical form. A crystalline salt often states the number of water molecules in its formula, such as MgSO₄·7H₂O, giving a different molar mass from the anhydrous form.

On dissolution, that water contributes to the water balance, not additional magnesium. Equal masses of different hydrate forms therefore do not preserve the same salt or elemental inventory.

Foundations: 11965 – DMEM, high glucose: formulation

Used in these chapters · 2
Back to the term directory

Hydraulic power

Related search terms: hydraulic power

Hydraulic power for an approximately incompressible liquid across a pressure difference is P = QΔp. Using m³/s and Pa gives watts. Flow and pressure difference must refer to the same operating point and boundary.

Electrical input is typically greater because of drive and pump losses. Conversion requires efficiency appropriate to that operating point. Maximum pump flow and maximum head are not automatically achieved together.

Foundations: Improving Pumping System Performance: A Sourcebook for Industry

Used in these chapters · 1
Back to the term directory

Hydraulic residence time

Hydraulic residence time characterises liquid exchange. At constant working volume V and steady throughput F, τ = V/F = 1/D. With V expressed in L and F in L/h, τ is measured in hours. A reactor containing 10 L with a throughput of 2 L/h therefore has a hydraulic residence time of 5 h.

This mean does not imply that every liquid element spends exactly five hours inside. Mixing, bypass flow and poorly exchanged regions produce a residence-time distribution. Cell retention may make cellular residence much longer. For secreted product stability, actual passage and retention of the product must also be considered.

Used in these chapters · 7
Back to the term directory

Hydrofoil impeller

A hydrofoil impeller uses shaped blade profiles to generate directed flow with a favourable relationship between pumping and power consumption. Many designs are predominantly axial-flow. The term nevertheless covers different geometries and does not prescribe one power number or a universally acceptable level of stress for cells.

Hydrofoils can be useful for bulk circulation, but their ability to distribute gas or suspend particles must be assessed for the actual duty. Low power draw at a fixed rotational speed is not sufficient evidence of superior performance if the required mixing task remains unmet. Comparing designs at equal required pumping or another clearly defined process outcome gives a more meaningful engineering assessment.

Used in these chapters · 1
Back to the term directory

Hydrostatic pressure

Hydrostatic pressure results from the weight of a stationary fluid. At constant density, pressure increases by ρgh with depth h below a specified reference level.

An aerated or flowing reactor involves additional effects. Headspace pressure alone is therefore not always the appropriate local pressure for gas-solubility calculations. At constant density, the pressure difference is ρgh. Pressure at the free surface supplies the boundary value, so the equation does not automatically give absolute pressure. An aerated or stratified system requires an appropriate local or height-dependent density and an assessment of the simplification being used.

Foundations: University Physics 14.1: pressure with depth

Used in these chapters · 3
Back to the term directory

Hygiene

Related search terms: hygienic operation

Hygiene comprises organisational and technical measures that prevent harmful contamination or keep it within appropriate limits. In bioprocessing, these include a cleanable environment, suitable clothing, controlled material movements and careful handling of open connections. Measures are selected according to the process and its possible contamination sources, rather than the visual impression of cleanliness alone.

Hygienic does not mean sterile. Hygienically designed and cleaned equipment may still contain viable microorganisms. Aseptic operation requires additional barriers and suitable sterilisation steps. Unhygienic storage or assembly can compromise the protected condition of a sterile component, particularly if its packaging or sterile barrier is affected. Effective hygiene therefore connects equipment construction, working practices and verifiable maintenance of the facility and its associated process equipment.

Used in these chapters · 5
Back to the term directory

Hygienic design

Related search terms: hygienic engineering

Hygienic design shapes equipment so that contamination is prevented and the intended cleaning procedures can work effectively. It includes accessible or adequately reached surfaces, suitable materials, properly executed connections and controlled drainage. Requirements depend on the product, soil and cleaning method; a polished appearance is not a reliable substitute.

Hygienic construction is not automatically aseptic. Preserving a sterile barrier requires additional consideration of seals, sterilisability and protected connection procedures. Certification of individual components also does not automatically establish suitability of the complete installation. Orientation, mating components and operating sequence can create new unfavourable regions. Design decisions should therefore be evaluated together with the intended operation and the way its effectiveness will be demonstrated.

Used in these chapters · 3
Back to the term directory

Hygroscopicity

Hygroscopicity describes a material’s tendency to take up water from its surroundings. Extent and rate depend on material form, humidity, temperature and exposure time.

Water uptake in a medium powder can change the basis of a weighed quantity. Closed storage and documented handling support consistent assay interpretation. Hygroscopic does not automatically mean complete liquefaction; the more specific term is deliquescence.

Foundations: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances · Water Activity (aw) in Foods

Back to the term directory

Hypha

Related search terms: hyphae

A hypha is a filamentous component of the vegetative body of a filamentous fungus. Hyphae can branch and contribute to mycelia or larger aggregates.

Length and branching describe morphology, not viability or product formation alone. Sampling and image processing can affect these structural measurements. Diameter, branching and length can contribute to description but are not interchangeable metrics. A two-dimensional projection may conceal overlaps. Observing a broken structure in an image also does not automatically show whether breakage occurred in the culture or during sampling and specimen preparation for analysis.

Foundations: A Library of Aspergillus niger Chassis Strains for Morphology Engineering

Used in these chapters · 3
Back to the term directory

Hysteresis

Hysteresis means that a system response depends on its preceding history. An instrument may show different readings at the same input depending on whether the measured quantity was previously increasing or decreasing. In switching functions, deliberately specified hysteresis instead describes the separation between activation and deactivation thresholds.

Such switching hysteresis can prevent a pump repeatedly starting and stopping because of small fluctuations or noise. It is then an intended feature rather than a sensor defect. Measurement hysteresis, switching hysteresis and simple time delay must therefore be distinguished. Checking a sensor only in one direction may miss relevant behaviour; increasing and decreasing reference sequences can reveal deviations hidden by a single calibration point.

Used in these chapters · 3
Back to the term directory

I

Image segmentation

Related search terms: segmentation

Image segmentation assigns image regions to defined objects or classes, such as biomass and background. It provides the basis for area and shape measurements.

Thresholds, illumination and separation of touching objects can alter descriptors. Preserve settings and original images, and assess them using representative examples. Merging neighbouring objects or splitting a poorly visible object changes counts and size distributions. Keeping software settings constant does not ensure equal error across different image contrasts. Review images should therefore include the actual difficult cases and establish whether the biological conclusion survives defensible analysis changes.

Foundations: A Library of Aspergillus niger Chassis Strains for Morphology Engineering

Used in these chapters · 1
Back to the term directory

Immobilisation

Related search terms: Immobilization, Immobilised, Immobilized

Immobilisation deliberately restricts a biocatalyst’s spatial mobility, for example by attaching it to a carrier or entrapping it within a matrix. This can retain the catalyst in the reaction system or allow separation for subsequent use. It differs from simply increasing the concentration of cells or enzymes.

The amount bound does not establish how much activity remains accessible under process conditions. Substrates must reach active regions and products must leave them. Carrier loading, accessible activity and activity loss over time therefore require separate assessment. Immobilisation does not automatically improve stability or reuse; outcomes depend on catalyst, attachment method, carrier and exposure. Material remaining in supernatants and wash fractions also belongs in the loading balance.

Foundations: Serial et al.: Quantifying enzyme immobilization in porous carriers

Used in these chapters · 4
Back to the term directory

Impeller

An impeller is the moving component of an agitator that transfers mechanical energy directly to the liquid. Its surfaces generate directed pumping and local differences in velocity. Depending on geometry, the design may emphasise bulk circulation, bubble break-up or particle suspension, while often performing several tasks at once.

Diameter and blade count do not fully describe an impeller. Blade profile, pitch, rotation direction, installation position and interactions with other stages all affect its function. Two impellers running at the same speed can draw very different power and produce different flow fields. Comparison should therefore start with the required process duty and suitable performance measures, rather than visual similarity alone.

Used in these chapters · 14
Back to the term directory

Impeller flooding

Related search terms: Flooding

Impeller flooding is an unfavourable operating condition in which gas loading severely impairs an impeller's ability to capture and disperse gas effectively. Gas may follow preferential routes while the intended liquid pumping and dispersion weaken. The term does not mean that liquid is overflowing from the vessel.

The boundary depends on impeller design, speed, gas flow, installation geometry and liquid properties. Adding more gas in this region therefore does not necessarily increase useful oxygen transfer. A change in power draw may indicate altered gas behaviour around the impeller, but cannot provide a complete diagnosis alone. Sound design considers the full operating range, rather than only the maximum flow available from the gas supply.

Back to the term directory

Impeller tip speed

Related search terms: Tip speed

Impeller tip speed is the circumferential speed at an impeller's outer radius. It is calculated as utip = π · d · N, where d is impeller diameter in m and N is rotational frequency in s⁻¹, giving m/s. A speed stated in revolutions per minute must first be divided by 60.

The quantity describes impeller motion, rather than a liquid velocity present everywhere or a directly defined shear stress. It can serve as an engineering comparison criterion but does not fully capture blade geometry, viscosity or local flow. Equal tip speed in differently sized vessels therefore does not automatically provide equal mixing time, power density or biological exposure for the culture.

Used in these chapters · 4
Back to the term directory

Impulse response

An impulse response describes a system responding to an idealised brief input with defined integrated magnitude. A real tracer pulse has finite duration.

The observed trace may therefore contain pulse width and sensor lag in addition to reactor dynamics. Transport interpretation requires separating or jointly modelling these contributions. For a linear time-invariant system, response to a general input can be obtained by convolving that input with the impulse response. With a conservative tracer, integrated discharged mass is also compared with injected mass; the curve shape alone does not exclude losses or unmeasured outlets.

Foundations: Chapter 16: Distributions of Residence Times for Chemical Reactors · Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

In-vitro cell age

Related search terms: Cell age

Documented proliferation or time history of cultured cells relative to a defined origin. Depending on context it may be expressed as population doublings, culture duration or a passage convention; these measures are not generally interchangeable.

Equal numerical age does not guarantee equal physiological state. Conditions, losses and branching may differ. A comparison or stability statement should therefore include reference origin, age measure and relevant history together.

Foundations: ICH Q5D: Derivation and Characterisation of Cell Substrates Used for Production of Biotechnological/Biological Products

Used in these chapters · 5
Back to the term directory

Independent replication

Related search terms: Replication, Biological replicate

Independent replication applies a condition to another suitable experimental unit. It provides information on variation between such units insofar as their independence and comparability are justified.

Two analyses of the same sample are technical repeats and do not measure between-run variation. Reports therefore distinguish numbers of cultures, samples and analyses. The label biological replicate alone does not replace a description of the level that is actually independent.

Foundations: Randomized block designs

Used in these chapters · 18
Back to the term directory

Inert-gas balance

An inert-gas balance uses a component without relevant formation, uptake or accumulation to determine quantities such as unknown outlet gas flow.

Nitrogen serves this role only under appropriate biological and physical conditions. Gas switching, leaks, dissolution and biological nitrogen conversion can invalidate the simplified balance. At steady state, ṅinyinert,in = ṅoutyinert,out. Both sides need compatible wet or dry bases. A remainder calculated as one minus O₂ and CO₂ represents nitrogen only when other components are excluded or accounted for at the accuracy required for that balance.

Used in these chapters · 2
Back to the term directory

Information model

Related search terms: data model

An information model describes objects, properties and relationships in a structured form. It can specify which sensors belong to a vessel, the unit of a measurement and available actions. It differs from the transmission channel or file extension alone.

In bioprocessing, an agreed model helps associate measurements with the correct batch, sample and equipment function. Different names or structures require an explicit mapping. A model may be scientifically incomplete even when its files can be read technically.

Foundations: Unified Architecture overview

Used in these chapters · 3
Back to the term directory

Inline measurement

Inline measurement examines material while it remains in the actual process stream or reactor. An immersed pH probe is a typical example; suitable optical measurement through a window can also be inline. The term describes how measurement is integrated rather than automatically specifying its speed or analytical accuracy.

Inline methods avoid separate sample withdrawal and support frequent observation. The sensor, installation and measuring range must withstand process conditions. Deposits, gas bubbles and local gradients can influence results, and one location does not necessarily represent the entire vessel. Everyday terminology sometimes calls inline measurements online; technical comparisons should therefore explicitly describe the actual measurement arrangement.

Back to the term directory

Inoculum

Related search terms: Seed culture, Inoculant

The inoculum is the living starting material used to establish a new culture. It may contain vegetative cells, a cell suspension or suitable fungal spores. Its amount matters, but so do its physiological state, identity and cultivation history. Two inocula of equal volume can therefore introduce very different numbers of active cells.

An appropriately prepared inoculum reduces unwanted adaptation periods and improves comparability between successive cultures. The accompanying liquid also matters because it carries nutrients, inhibitory compounds or metabolic signals into the receiving culture. A percentage inoculation volume describes dilution only; it does not replace information about cell content, growth state and transfer timing. These biological attributes explain why merely increasing the inoculum volume may fail to correct an inconsistent start.

Used in these chapters · 24
Back to the term directory

Input/output

Related search terms: I/O, IO, inputs and outputs

Input/output, or I/O, refers to interfaces and the signals or data passing through them. Direction is relative to a specified system: a controller input may receive a measurement or switch state, while an output transmits a command to a connected device. Communication may use individual signal channels or a data connection.

A bioreactor I/O list assigns signals to devices and functions. Design work should establish direction, signal type, range, scaling and required update frequency. Available channel count alone does not establish compatibility. Nor does an issued command demonstrate that the device achieved the intended effect; suitable feedback may be needed to establish that.

Foundations: SP 800-82 Rev. 3 publication page

Used in these chapters · 6
Back to the term directory

Insect cells

Related search terms: Sf9, Sf21

Insect cells are cultured cells originating from insects, including the Sf9 and Sf21 lines used for protein expression. They support the manufacture of complex biological products and can grow in suspension in suitable systems. Baculovirus-based expression is widely used, but it is not the only way to produce proteins in insect cells.

Cell expansion and subsequent expression can pursue different biological objectives. Conditions that promote rapid growth are therefore not automatically those that maximise product formation. Temperature requirements, media and protein processing also differ from those of typical mammalian cell cultures. Actual product structure must be examined, especially for therapeutic proteins: using a eukaryotic host does not guarantee identical glycosylation across different animal groups.

Used in these chapters · 2
Back to the term directory

Installation qualification (IQ)

Related search terms: installation qualification

Installation qualification documents that equipment has been installed in accordance with the approved design and relevant requirements. Checks may cover component identity, construction materials, service connections, orientation and availability of necessary documentation. Identification of measurement points and an appropriate calibration status also support subsequent testing.

IQ concerns the installation actually present. A delivery note alone does not demonstrate that a component is correctly fitted or connected to the right utility. Conversely, correct installation does not establish that the equipment functions throughout its intended operating range. Those functional questions are addressed by further testing. The documented scope follows relevant requirements and risks; not every screw needs the same depth of examination as a critical sterile barrier.

Used in these chapters · 3
Back to the term directory

Installed capacity

Related search terms: installed capacity

Installed capacity describes an equipment stock or its possible performance under defined conditions at a point in time. A litre figure initially describes volume. It is not automatically annual production.

Converting bioreactor capacity into product quantity requires assumptions about batch count, titre, recovery and availability. Different designs and applications cannot be compared meaningfully merely by adding inconsistently defined litre figures.

Used in these chapters · 3
Back to the term directory

Integrated fixed-film activated sludge

Related search terms: IFAS

IFAS combines suspended activated-sludge biomass with additionally retained biofilm biomass in one treatment concept. The two biomass forms may experience different retention and transport conditions.

The approach therefore differs from suspended activated sludge alone and from a carrier-only process. Performance assessment considers both inventories, carrier accessibility, oxygen supply and solids export. Additional nominal carrier area is not by itself evidence of a specified nitrogen-removal capacity.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Integrated viable cell density

Related search terms: IVCD

Time integral of viable cell density, such as ∫X_vdt in cells·day/mL. It summarises viable concentration over time. With variable reactor volume, distinguish it from the integral of total viable cell quantity, ∫X_vVdt.

Specific product formation needs a cell-time basis matching its product balance. Concentration and cell-quantity integrals cannot be interchanged without a volume assumption. Samples, bleed and interpolation between observations affect the complete calculation.

Used in these chapters · 3
Back to the term directory

Internal rate of return

Related search terms: IRR

An internal rate of return is a discount rate at which a cash-flow series has zero net present value. Depending on the sequence of payment signs, multiple solutions or no meaningful solution may exist.

The percentage alone cannot rank equipment projects of different size or timing. Decisions still need absolute cash-flow effects and a justified common valuation basis. A calculated return also inherits the uncertainties in its revenue and cost assumptions.

Foundations: 11.4 Discounted Cash Flow Models

Back to the term directory

International System of Units (SI)

Related search terms: SI, SI units

The International System of Units is a coherent system for expressing physical quantities. Its definition fixes numerical values of seven defining constants. Familiar base units include second, metre, kilogram, kelvin and mole; derived units include pascal for pressure and watt for power.

Reactor calculations require consistent numerical values and units. One litre equals 0.001 m³ and one hour 3,600 seconds. Combining kLa in h⁻¹ with molar flows in mol/s requires conversion of the time basis. A unit alone does not identify a measurand: joules per kelvin can describe heat capacity or entropy. A dimensionless value also needs its reference quantity explained.

Foundations: BIPM: A concise summary of the International System of Units

Used in these chapters · 1
Back to the term directory

Interoperability

Related search terms: interoperable

Interoperability is the ability of different systems to exchange information or functions in a way usable for their shared task. It involves connectivity, compatible formats and agreement about the meaning of exchanged content. A physical or network connection alone does not automatically satisfy these levels.

When a bioreactor transmits temperature, the receiving application must correctly interpret units, timing and validity. Successful transmission of a number is therefore partial evidence. Assessment should address the workflow actually required.

Foundations: Unified Architecture overview

Used in these chapters · 2
Back to the term directory

Intron

An intron is a transcribed region removed during splicing from the mature RNA being considered. Genomic sequence and mature RNA therefore differ in their sequence of regions. Introns should not simply be equated with functionless DNA; they may, for example, have regulatory roles.

Characterising a production construct requires stating whether a finding concerns genomic DNA, precursor RNA or mature RNA. Otherwise, differences in region length are easily misinterpreted. Absence of an intron from mature RNA does not, by itself, demonstrate loss of that region from the genome.

Foundations: NHGRI: Intron

Back to the term directory

Inventory position

Related search terms: inventory position

Inventory position combines quantities relevant to an ordering decision under a defined convention. It may include on-hand stock, outstanding orders and reserved demand. The exact calculation must fit the planning method.

For bioreactor sets, only timely usable and suitable versions count towards availability. Damaged, blocked or expired quantities must not silently become available reserve. Counting physical boxes alone therefore does not fully describe inventory position.

Used in these chapters · 1
Back to the term directory

Ionic strength

Ionic strength weights dissolved-ion concentrations by squared charge number: on a concentration basis, I = ½Σcᵢzᵢ². A molality basis can also be used and must be specified.

Divalent ions contribute more than monovalent ions at equal concentration. Ionic strength is neither osmolality nor conductivity. Media calculations must consider free species and binding; an ingredient-only calculation may be merely a formal approximation.

Foundations: 11.4 Colligative Properties · Quantities, Units and Symbols in Physical Chemistry (IUPAC Green Book)

Used in these chapters · 3
Back to the term directory

Irradiance

Irradiance is incident radiant power per unit area, typically expressed in W m⁻². Measurement refers to a defined orientation and, where applicable, a specified wavelength range.

It is an energy-based quantity and differs from photon flux density. The same number of photons carries more energy at shorter wavelengths. Converting a broad spectrum requires its spectral distribution; an arbitrary single conversion factor is not generally valid.

Foundations: Measuring PPFD and PPFFR with underwater sensors · Fundamental Physical Constants — Complete Listing

Used in these chapters · 2
Back to the term directory

Isoelectric point

Related search terms: pI

The isoelectric point pI is the pH at which the amphoteric species considered has zero mean net charge under specified conditions. It does not mean absence of local charges throughout the molecule.

Proximity to pI may affect protein separation and solubility without implying a universal precipitation rule. Medium, salt content and molecular structure remain relevant. pI and pKₐ describe different properties.

Foundations: 26.2 Amino Acids and the Henderson–Hasselbalch Equation: Isoelectric Points

Back to the term directory

IT authentication

Related search terms: authentication, IT authentication

IT authentication verifies the claimed identity of a user, programme or device. It supports access decisions but does not itself grant every permission. Procedures and required evidence depend on the system.

A bioreactor platform should identify human users and connected applications appropriately. Successful login says nothing about whether a subsequent process change is scientifically justified. Identity, permission and substantive approval therefore remain separate considerations.

Foundations: Authentication

Back to the term directory

K

Kjeldahl nitrogen

Related search terms: TKN, Total Kjeldahl nitrogen

Total Kjeldahl nitrogen denotes ammonium nitrogen plus organic nitrogen recovered by the specified Kjeldahl method. Conventional TKN reporting does not include nitrate and nitrite.

TKN and total nitrogen are therefore not interchangeable. A species balance must examine the method and any compounds it does not fully recover. TKN can decrease through nitrification while total nitrogen remains unchanged, so a decrease does not prove gaseous nitrogen removal.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Kolmogorov length scale

Related search terms: Kolmogorov microscale

The Kolmogorov length scale is a characteristic small scale of turbulent flow at which viscous effects play a dominant role in dissipation. The associated turbulence model gives η = (ν³/ε)1/4, using kinematic viscosity ν in m²/s and mass-specific dissipation rate ε in m²/s³. The resulting η is expressed in metres.

It is sometimes compared with cell or aggregate diameter to assess hydrodynamic exposure, but it is not a universal damage threshold. The model requires appropriate turbulent conditions, and local ε may differ greatly from the vessel average. Cell mechanics, deformability, interfacial contacts and exposure duration remain relevant. A small calculated value alone consequently proves neither cell damage nor reactor unsuitability.

Back to the term directory

Kurtosis

Related search terms: Excess kurtosis

Moment-based kurtosis is the fourth central moment divided by variance squared, provided these moments exist. It equals three for a normal distribution; excess kurtosis subtracts three.

The measure is sensitive to large standardised deviations and should not be interpreted simply as peak height. Software may report kurtosis or excess and use different sample corrections. Process comparisons therefore require the convention, sample size and possible outliers to be known.

Foundations: Measures of skewness and kurtosis

Back to the term directory

L

Laboratory & Analytical Device Standard (LADS)

Related search terms: LADS

LADS is an OPC UA-based specification for describing and integrating laboratory and analytical devices. It provides a shared model for device information and functions. A common model can simplify integration but does not replace assessment of the features actually implemented.

For a cultivation platform, establish the version and functions supported by the device and its counterpart. Mentioning LADS proves neither availability of every required measurement channel nor a fully automated laboratory workflow. Sample association and process context remain application concerns.

Foundations: Introduction to LADS — OPC UA for Laboratory & Analytical Device Standard · OPC 30500-1 LADS Basics

Used in these chapters · 2
Back to the term directory

Lack of fit

Lack of fit is the component of residual sum of squares remaining after pure error is subtracted. It compares the chosen model form with the means at replicated conditions.

A corresponding test requires suitable replication and an appropriate error model. A non-significant result does not prove the model form correct: limited information may leave relevant deviations undetected. External confirmation and residual examination complement this assessment.

Foundations: Testing missing or misspecified model terms

Used in these chapters · 1
Back to the term directory

Lagrangian description

Related search terms: Lagrangian perspective

The Lagrangian description follows moving material elements or representatives and records states along their paths. In a bioreactor it can reveal exposure histories.

Whether a computed particle adequately represents a cell depends on size, density, attachment and retention. Its motion model must suit the question. Even a time-invariant spatial concentration field can create varying exposure along a moving path. Population interpretation requires appropriate weighting and selection of representative paths. The sheer number of computed points does not demonstrate adequate coverage of rare pathways or biologically important subgroups within the population.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Used in these chapters · 1
Back to the term directory

Laplace distribution

Related search terms: Double exponential distribution

The Laplace distribution is a symmetric continuous distribution with density proportional to exp(−|x − μ|/b), where b > 0. It has a peak at μ and heavier tails than the normal distribution.

It may be investigated as an alternative error model when the data pattern and question support it. Scale b is not the standard deviation, which equals √2·b. An alternative distributional fit does not replace investigation of unusual process states or measurement errors.

Foundations: Double exponential distribution

Back to the term directory

Leachables

Related search terms: leachable substances

Leachables are substances that migrate from a contact material into process fluid or product under actual or representatively simulated use conditions. They can include original constituents, additives and their degradation products. Released amounts depend on contact time, temperature, medium composition and the ratio of contact area to liquid volume. Prior sterilisation and storage can alter the profile.

Assessment considers both possible effects on the culture and requirements for the eventual product. A low total amount is not automatically harmless if an individual substance has strong biological activity. Extractables data can support the investigation but do not always replace assessment of actual exposure. Substances may also be removed or chemically transformed during subsequent processing, which needs to be considered explicitly.

Used in these chapters · 1
Back to the term directory

Least privilege

Related search terms: least privilege

Least privilege limits access to what is necessary for an assigned task. It applies to people and automatically operating programmes. Permissions follow required functions rather than convenience alone.

A service reading fermentation data does not automatically need permission to change pump setpoints. Review rights when duties change. Excessively restrictive rights can also obstruct intended operation, so the actual configuration requires practical verification.

Foundations: Least Privilege

Back to the term directory

Least squares

Related search terms: Ordinary least squares, OLS, Least-squares method

Least squares chooses model parameters to minimise the sum of squared differences between observations and model values. Ordinary least squares gives equal weight to all included observations.

This numerical fit must be distinguished from its statistical interpretation. Uncertainty formulas require appropriate assumptions about variation and dependence. Substantially different measurement uncertainties may warrant justified weighting; squaring does not remove outliers or model inadequacy.

Foundations: 4.1.4.1 Linear Least Squares Regression · How can I tell if a model fits my data?

Used in these chapters · 2
Back to the term directory

Life cycle assessment (LCA)

Related search terms: LCA, life-cycle assessment

Life cycle assessment examines environmental aspects of a defined product function over specified life-cycle stages. It connects goal and scope, inventory, impact assessment and interpretation. One electricity-consumption figure is not a complete LCA.

Relevant bioprocess stages may include raw materials, production, utilities, use and end treatment. Report omissions and data quality. Comparison needs the same functional unit and suitable methods for the impact categories actually considered.

Foundations: Life Cycle Assessment & EF methods

Used in these chapters · 3
Back to the term directory

Life cycle inventory

Related search terms: LCI

Life cycle inventory records relevant material and energy inputs and outputs within a bounded life cycle. It initially contains physical quantities and their allocation. Assessing potential environmental effects is a distinct subsequent stage.

Document measured water, estimated material and allocated shared energy with data status. Missing flows are not automatically zero. The structure enables targeted measurement of important contributions and consistent application of different impact methods.

Foundations: Life Cycle Assessment & EF methods

Back to the term directory

Light absorption

Light absorption transfers energy from a radiation field to matter and removes the corresponding photons from that field. In an algal culture, pigments and other constituents may absorb light.

Not all absorbed energy contributes to formation of the desired product. Reduced directional transmission can also result from scattering. Balancing incident, outgoing and absorbed radiation therefore requires more information than one detector behind a turbid sample.

Foundations: Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 1
Back to the term directory

Light compensation point

Related search terms: Compensation irradiance

At the light compensation point, photosynthetic gain balances opposing losses under the conditions considered, giving zero net conversion on the chosen basis. This is frequently described through carbon or oxygen exchange. The balance used must be stated explicitly because other metabolic pathways can affect the relationship between the two gases.

Below this point, photosynthetic gains cannot offset the losses considered; above it, positive net conversion can become possible. The value depends on the organism, temperature and physiological state. It is not a universal setpoint for an entire reactor, where cells can experience very different light conditions. Zero net gas exchange also does not mean that the cells are metabolically inactive.

Back to the term directory

Light limitation

Related search terms: Light-limited growth

Light limitation occurs when available usable radiation restricts photosynthetic conversion or growth. It can affect individual cells or the reactor as a whole. As cell density rises, a finite photon supply is shared among more biomass, so specific growth rate can fall even when nutrients remain adequate.

Increasing light is appropriate only if other requirements, including carbon supply and temperature, remain favourable. In a dense culture, stronger external illumination may mainly burden the outer region without sufficiently supplying the interior. Light limitation therefore needs spatial interpretation. Linear biomass accumulation under constant illumination can be consistent with limited total photon supply and does not necessarily indicate a biological failure.

Used in these chapters · 1
Back to the term directory

Light scattering

Related search terms: Scattering

Light scattering changes radiation propagation direction through interaction with matter. In elastic scattering, photon energy is unchanged while the radiation field is redistributed spatially and directionally.

Cells and bubbles may thereby reduce measured directional transmission without absorbing an equal amount of energy. Multiple scattering complicates interpretation of a simple exponential fit. Reactor geometry and the outgoing directions measured are explicitly considered in a defensible light balance.

Foundations: Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 9
Back to the term directory

Light-emitting diode

Related search terms: LED

A light-emitting diode, or LED, is a semiconductor component that emits light under suitable electrical excitation. Individual coloured LEDs generally have a relatively narrow spectrum; white light can be produced by mixing colours or phosphor conversion.

For photobioreactors, the spectrum reaching the culture, photon quantity and energy demand of the complete luminaire including its power supply matter. The label LED alone guarantees neither a specified biological effect nor fixed efficiency or lifetime.

Foundations: LED Basics

Used in these chapters · 1
Back to the term directory

Light–dark cycles

Related search terms: Flashing-light effect

Light–dark cycles are repeated transitions between differently illuminated states. In a moving algal culture, they can arise as cells travel between illuminated outer regions and darker interior zones. Temporally switched light sources produce related patterns. Biological effects depend on both the duration and intensity of the bright period and the length of the intervening darkness.

Rapid transitions can behave differently from uninterrupted illumination with the same average intensity because photochemical processing and regulation have their own timescales. This does not establish a universal productivity advantage for pulsed light. Comparisons must account for total photon input and the complete cycle duration. Such rapid transitions also differ from a photoperiod containing hours-long day and night intervals.

Back to the term directory

Limiting substrate

Related search terms: Growth-limiting substrate

A limiting substrate is a required resource whose availability restricts growth or conversion rate under the prevailing conditions. The lowest measured concentration is not automatically decisive: demand, uptake capacity and other resources jointly determine whether supply is sufficient. Several factors can also impose limitations simultaneously.

Deliberate limitation can help control metabolic behaviour, but it differs from complete nutrient starvation. Restricted supply can sustain a limited conversion rate, whereas full depletion may shift cells into another physiological state. An increasing dissolved oxygen value alone likewise does not prove limitation by a particular substrate. A convincing interpretation combines material balances with the biological response to a change in supply.

Used in these chapters · 1
Back to the term directory

Linear regression

Fitting a model that is linear in the parameters being estimated. The straight line y = a + bx is an important special case. It describes relationships between explanatory quantities and a response under explicitly chosen model assumptions.

Linear does not require every raw variable to remain untransformed. Fitting ln X against time estimates an exponential relationship on a transformed scale. A good fit establishes neither causation nor biological validity outside the observed range.

Foundations: 4.1.4.1 Linear Least Squares Regression

Used in these chapters · 4
Back to the term directory

Linear viscoelastic region

Within the linear viscoelastic region, oscillatory stress responds linearly to imposed strain. At specified frequency and temperature, measured moduli are approximately independent of amplitude.

The useful region must also provide sufficient signal. Very small amplitudes may be unsuitable experimentally, whereas large amplitudes can change structure. Limits are determined for the material and conditions. Amplitude assessment is conducted under specified frequency, temperature and sample conditions. The resulting region does not automatically apply at another frequency or after sample ageing. Selecting an amplitude for subsequent measurements considers both adequate signal quality and avoidance of an unintended change in material structure.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

Little’s law

Related search terms: Little’s law

Little’s law relates mean inventory L, mean throughput λ and mean time W through L = λW. All quantities need the same system boundary, quantity definition and compatible averaging conditions. A queue-only boundary counts its waiting time only.

The identity does not automatically predict a waiting-time distribution. Finite windows with non-empty boundary inventories need appropriate treatment. Multiplying an ideal sustained rate by differently bounded finite waiting time can give a wrong result.

Foundations: Basic Concepts in Queueing, lecture8

Back to the term directory

Load pattern

Related search terms: loading pattern, load arrangement

A load pattern specifies the arrangement of articles being treated or relevant configuration of a fixed system. Number, orientation, fill, material and packaging may influence heat and gas paths.

Equal total mass therefore does not guarantee the same thermal challenge. Evidence must match the permitted pattern; later changes can alter relationships between routine probes and difficult locations. One practical example is changed component orientation that retains air or condensate at a previously freely drained or ventilated location.

Foundations: Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 1
Back to the term directory

Load profile

Related search terms: load profile

A load profile describes demand or occupancy over time. Each value needs a unit, reference point and an indication of whether it is instantaneous or an interval average.

Utility planning combines profiles on the same time axis and with compatible system boundaries. Energy is obtained by integrating power over time. Reordering demands can therefore change required peak power without changing total energy.

Foundations: University Health Service process analysis, lecture10 · Steam Accumulators

Used in these chapters · 5
Back to the term directory

Log mean temperature difference (LMTD)

Related search terms: LMTD, logarithmic mean temperature difference

LMTD describes effective mean thermal driving force under suitable exchanger-model assumptions. For positive endpoint differences it is (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂). Equal differences use the continuous limit: their common value.

Endpoint differences must match flow arrangement. The usual Q̇ = UA·LMTD relation needs suitable steady-flow and heat-transfer assumptions; complex arrangements may require corrections. An arithmetic temperature mean is not generally equivalent.

Foundations: 18.5 Heat Exchangers · Heat Transfer

Back to the term directory

Log reduction

Related search terms: decimal reduction, decimal reductions

Log reduction is a base-ten logarithmic decrease in an appropriately determined population or quantity, such as log₁₀(N₀/N). Six log reductions correspond to a millionfold ratio.

An observed or modelled reduction is not directly a probability of a nonsterile product unit. That also needs initial burden, distribution assumptions and suitable evidence. A detection limit must not be inserted into the logarithm as a measured zero.

Foundations: Steam Sterilization – Guideline for Disinfection and Sterilization in Healthcare Facilities

Used in these chapters · 3
Back to the term directory

Lognormal distribution

A positive quantity is lognormally distributed when its natural logarithm is normally distributed. In this convention, μ and σ refer to the logarithm rather than directly to the original observations.

Its median is exp(μ), while its mean is exp(μ + σ²/2). Back-transforming a logarithmic mean therefore does not automatically recover the arithmetic mean. For concentrations or size distributions, zeros, detection limits and the plausibility of a multiplicative model require additional assessment.

Foundations: Lognormal distribution

Back to the term directory

Loss factor

In linear oscillatory shear, loss factor tan δ equals G″/G′. It compares dissipative and elastic response contributions.

The ratio is dimensionless but depends on frequency and state. One value establishes neither a yield stress nor a universal transition for a living culture broth. Identical loss factors can accompany very different absolute moduli: doubling G′ and G″ together leaves their ratio unchanged. Engineering comparisons therefore report the ratio and both individual quantities. The ratio alone does not fully describe the magnitude of mechanical response under the stated measurement conditions.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

Loss modulus

Shear loss modulus G″ describes the dissipative part of linear oscillatory shear response and is measured in Pa. Together with G′ it characterises frequency-dependent viscoelasticity.

Dissipation during a small sinusoidal test is not identical to global impeller power input. Connecting them requires an appropriate flow and material model. In a linear sinusoidal test, this stress component is shifted by a quarter-period relative to strain. Interpretation needs the measurement frequency and strain amplitude. An amplitude-dependent change may indicate departure from the assumed linear regime and should not silently be treated as an unchanged frequency-dependent material property.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

Low-bioburden condition

Related search terms: low bioburden

A low-bioburden condition means that microbial contamination is low according to specified criteria. Unlike sterile, the term does not imply the complete absence of viable microorganisms. A meaningful specification therefore identifies the test method, reference quantity, acceptable burden and, where relevant, organisms that must be absent. Without these details, “low bioburden” is an imprecise quality description.

For an intermediate, a short holding period followed by suitable treatment may make a limited burden acceptable. This cannot automatically be extended to sensitive cell cultures or lengthy aseptic operations. A low viable count after treatment can also coexist with endotoxins released previously. Suitability therefore follows from the subsequent processing step and the risks posed to the product.

Used in these chapters · 2
Back to the term directory

Low-pass filter

Related search terms: low-pass

A low-pass filter attenuates high frequencies more strongly than low frequencies. It can reduce measurement noise while also suppressing or delaying rapid real changes.

Filter settings belong in measurement-chain documentation. A smoothed trace must not be presented as unchanged raw data or proof that rapid fluctuations were absent. A moving average combines neighbouring measurements. A causal filter uses only values already available and can serve an ongoing controller. A centred retrospective filter also uses future values; its apparently low-delay curve therefore does not represent information available immediately during operation at the displayed timestamp.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

M

Machine learning

Related search terms: ML

Machine learning develops models or decision rules from data for a specified task. Learned relationships may estimate measurements, assign classes or describe patterns in process data.

Good fit to training data does not guarantee suitable performance in subsequent cultures. Assessment separates complete independent runs and considers the intended domain of use. Learning methods are one part of artificial intelligence; their use replaces neither material balances nor scientific explanations of relationships.

Foundations: Machine learning — CSRC Glossary · Common pitfalls and recommended practices

Used in these chapters · 2
Back to the term directory

Magnetic coupling

A magnetic coupling transfers torque between driving and driven components through magnetic forces. In a bioreactor, a closed separating wall can lie between them, allowing rotation inside the culture chamber without a continuous shaft penetrating that wall. The arrangement may still contain internal bearings or other moving components.

Torque capacity is limited and depends on factors including geometry, separation distance and temperature. If the required torque exceeds the design capacity, synchronous transmission can be lost. A magnetic coupling therefore does not establish unlimited tolerance of viscous broth. Magnetically coupled and contactlessly supported also describe different properties: the drive principle does not by itself identify how the rotating assembly is supported.

Used in these chapters · 1
Back to the term directory

Main effect

A main effect describes the difference between factor levels averaged over an agreed distribution of other factors. In a balanced two-level design it is commonly the mean at +1 minus the mean at −1.

With interaction, this average can differ substantially from conditional comparisons. Weighting and factor range therefore belong with the result. In the corresponding balanced design with ±1 coding, the main effect is twice the linear coefficient.

Foundations: Two-level full factorial designs · Interaction effects matrix plot

Used in these chapters · 2
Back to the term directory

Maintenance metabolism

Related search terms: Cell maintenance

Maintenance metabolism covers energy and material expenditure that does not directly create new biomass. Cells need energy to maintain ion gradients, replace damaged components and regulate their internal environment. A culture can therefore consume substrate while its total biomass changes very little. Absence of net growth does not mean absence of biological activity.

At slow growth, maintenance can account for a substantial share of consumption and lower the observed biomass yield. This share is not a universal cellular constant: environmental stress, temperature and culture state affect it. A residual demand estimated from consumption data can also include unrecognised product formation or cell turnover. It should not automatically be attributed entirely to maintenance.

Used in these chapters · 4
Back to the term directory

Margin of safety

Related search terms: margin of safety

Margin of safety is the difference between planned or actual sales and break-even sales. It can be expressed as units, revenue or relative to the stated sales base.

This accounting margin is not a technical safety allowance. In a bioreactor campaign, product failures, delayed release or lower selling prices can reduce it. The comparison needs the same period and product mix as the underlying cost calculation.

Foundations: 3.5 Margin of Safety and Operating Leverage

Back to the term directory

Market share

Related search terms: market share

Market share is the ratio of an attributed quantity or revenue to the corresponding total for a clearly defined market. Numerator and denominator must share period, subject and geographical basis.

A country’s share of medicine revenues does not establish its share of bioreactor equipment sales. Nor does one large factory establish a national market share. Precise percentages are unjustified without comparable definitions and data.

Used in these chapters · 4
Back to the term directory

Markov process

Related search terms: Markov model

In a Markov model, conditional future development depends on the present state without additional dependence on earlier states. Constant transition rates in a simple continuous-time zone model produce exponential residence durations.

Memorylessness is a modelling assumption. Directed circulation, ageing or biological adaptation can require extra states or different residence distributions. For a well-mixed zone of volume V and constant exit flow Q, λ = Q/V is a possible transition rate and mean residence duration is 1/λ. A prescribed deterministic cycle with fixed zone durations has a different residence distribution and must be identified separately rather than treated as equivalent.

Used in these chapters · 1
Back to the term directory

Mass flow rate

Related search terms: Mass flow

Mass flow rate is the mass passing through a defined cross-section or accounting boundary per unit time. Its SI unit is kg/s; feed records also commonly use kg/h. For a sufficiently uniform stream, mass flow equals density multiplied by volumetric flow. The density must correspond to the actual composition and temperature.

A dose of 0.60 L/h at an assumed density of 1.20 kg/L delivers 0.72 kg/h of solution. At 40% glucose by mass, the glucose feed is 0.288 kg/h. Solution mass and substrate mass are distinct accounting quantities. The change in a supply-vessel scale represents pump delivery only when other additions and removals are excluded or measured.

Foundations: OpenStax University Physics 1: Fluid dynamics

Used in these chapters · 9
Back to the term directory

Mass fraction

Related search terms: mass percentage

Mass fraction is component mass divided by total mixture mass. It is dimensionless and often reported as a percentage; ten mass percent corresponds to 100 g component per kilogram of mixture.

Mass fraction is not concentration in g/L. Conversion requires suitable density. For a raw-material assay, also establish whether the denominator refers to material as supplied or a defined dry basis.

Foundations: 3.3 Molarity

Used in these chapters · 14
Back to the term directory

Mass load

Related search terms: Load, Daily load

A mass load is the quantity or mass transported over a defined period; usage often also denotes the associated rate, such as kg N d⁻¹. Under constant conditions, concentration multiplied by volumetric flow gives mass flow.

For time-varying streams, the product of simultaneous flow and concentration is integrated. Multiplying two unweighted averages may be wrong. Unit, period, chemical reporting basis and sample weighting are therefore stated together.

Used in these chapters · 16
Back to the term directory

Mass spectrometry

Related search terms: MS

Mass spectrometry generates ions from a sample and distinguishes them by their mass-to-charge ratio, m/z. The resulting signals can provide information about molecular identity, fragments and relative or calibrated quantities. Depending on the inlet and ionisation method, applications include process gases and chromatographically separated metabolites.

The technique does not simply measure the mass of every unchanged molecule directly. Different charge states, fragmentation and overlapping signals require consideration. Matrix effects may alter ion yield during quantitative analysis, making suitable standards and preparation essential. Gas analysis additionally depends on transfer lines, moisture and calibration gases. High instrumental resolution alone guarantees neither an unambiguous compound assignment nor a correct concentration.

Used in these chapters · 2
Back to the term directory

Mass-transfer driving force

A mass-transfer driving force expresses the departure from equilibrium that causes net transfer between regions or phases. For a simplified oxygen-transfer model, it is often written as c* − c: c* is the liquid equilibrium concentration corresponding to the gas phase, while c is the actual concentration in a well-mixed liquid bulk.

More interfacial area or stronger circulation can reduce a transport resistance but does not independently create unlimited driving force. As c approaches equilibrium, net inward transfer falls under otherwise unchanged conditions. If the difference becomes negative, material can leave the liquid. Local gas composition and pressure may vary in real vessels, making a single average driving force an assumption that requires assessment.

Back to the term directory

Master cell bank (MCB)

Related search terms: Master bank

A master cell bank is a characterised stock of consistently prepared, preserved portions of defined cellular material. It establishes the biological reference point for subsequent manufacture and permits repeated starts from a traceable source population. Its description includes the origin, derivation, identity and properties relevant to the intended application.

The master bank differs from an ongoing culture: a central purpose is to avoid uncontrolled chains of repeated passage. A large collection of frozen tubes is not, by itself, a dependable cell banking system. Preparation, storage, withdrawal and the relationship to subsequent banks must form a coherent system. A documented starting point also does not guarantee that cells remain unchanged through indefinitely extended cultivation.

Used in these chapters · 2
Back to the term directory

Material balance

Related search terms: Mass balance

Accounting for initial and final inventory, inputs, outputs, formation and consumption of a substance within a defined boundary. A conserved element has no reaction source term, whereas an individual compound can be formed or consumed by reaction.

Completeness depends on the included streams and inventories. A residual may reflect uncertainty, a missing stream or incorrect association. Perfect closure is not independent evidence when every value was generated from the same prescribed balance.

Foundations: Lecture13: Microbial growth and product formation kinetics

Used in these chapters · 34
Back to the term directory

Material inventory

Related search terms: Mass inventory

Quantity of a specified substance inside a defined system boundary at a particular time. For uniform concentration C and matching liquid volume V, inventory is C·V. Contributions from distinct phases or spatial regions are determined separately and added.

Inventory may be expressed in g or mol, whereas concentration uses g/L or mol/L. With changing volume, inventory and concentration may develop differently. A balance requires matching sampling time, material basis and the state before or after withdrawal.

Foundations: Lecture13: Microbial growth and product formation kinetics

Used in these chapters · 22
Back to the term directory

Matrix effect

Influence of sample components other than the analyte on a measurement. It may alter signal, recovery or sample preparation despite the same analyte quantity.

Calibration in a simple solution may therefore not transfer directly to complex broth. Dilution or suitable comparison samples can support investigation but do not replace method assessment. Distinguish a matrix effect from a real change in analyte inventory.

Foundations: Absolute bacterial cell enumeration using flow cytometry

Used in these chapters · 3
Back to the term directory

Matrix rank

Matrix rank is the number of linearly independent columns or rows. In regression, full column rank is the structural requirement for a unique least-squares estimate of all included coefficients.

Full rank does not guarantee a numerically stable or precise estimate: nearly dependent columns can produce large uncertainty. A missing corner or a factor identical to day must therefore be assessed using the specific model matrix.

Used in these chapters · 1
Back to the term directory

Maximum likelihood estimation

Related search terms: MLE, Maximum likelihood

Maximum likelihood estimation chooses parameters that give the observed data the greatest likelihood under a specified statistical model. Likelihood is considered as a function of parameters while the data remain fixed.

It is not a direct probability that a parameter is true. Results depend on model, data coverage and any censoring. Numerical optimisation may find local solutions; favourable asymptotic properties require suitable regularity conditions and are not guarantees for small samples.

Foundations: Maximum likelihood

Back to the term directory

Mean absolute error

Related search terms: MAE

Mean absolute error is the average absolute difference between predictions and reference values. It has the same unit as the response and prevents positive and negative deviations cancelling.

One MAE value does not show whether certain process phases are predicted particularly poorly. Weighting and the population assessed must be known. Reference-method accuracy also limits how confidently a deviation can be attributed to the model.

Foundations: Metrics and scoring: quantifying prediction quality

Used in these chapters · 1
Back to the term directory

Mean square error

Related search terms: MSE, Mean squared error

MSE may denote two related metrics depending on context. For prediction errors it commonly means the sum of squared deviations divided by n; in regression analysis of variance, mean square error is SSE divided by residual degrees of freedom.

The denominator must therefore be stated explicitly. For n observations and p estimable parameters it is n − p in an ordinary regression model. The metric has a squared unit and is not directly a standard deviation.

Foundations: Testing missing or misspecified model terms · Metrics and scoring: quantifying prediction quality

Used in these chapters · 3
Back to the term directory

Measurand

The measurand is the specified quantity whose value is to be determined, including necessary material, time, location and sample-handling conditions.

Total reactor product mass, concentration in a withdrawn sample and activity after downstream processing are different measurands. Precisely measuring the wrong quantity does not answer the process question. Define it before selecting the method and uncertainty calculation. For offline pH, for example, sampling time, temperature and gas equilibrium belong in the intended statement when they materially affect the value.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 5
Back to the term directory

Measurement model

A measurement model relates input quantities to the measurand. For example, it may combine concentration, dilution factor, volume and recovery into an estimated component mass.

The model must match the physical and analytical question. Correct uncertainty propagation cannot repair wrong substance identity or an invalid correction. Shared input sources may create correlations omitted by a simple root-sum-square calculation. For m = cV, the volume boundary of the desired inventory also matters: withdrawn sample, complete harvest and reactor contents are not interchangeable quantities.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 5
Back to the term directory

Measurement uncertainty

Measurement uncertainty is a non-negative parameter expressing how widely values assigned to a measurand are dispersed, given the available information. Contributions can arise from reference values, sampling, repeatability or correction models. Standard uncertainty is expressed as a standard deviation; expanded uncertainty multiplies it by a stated coverage factor. A coverage interval additionally requires information about coverage probability and assumptions.

For decisions, uncertainty must be sufficiently small relative to the relevant difference or boundary. It is neither a known error nor restricted to random scatter. Repeating analysis of the same sample does not automatically reduce systematic contributions. Calculated material balances need joint consideration of input uncertainties and possible dependencies. Decimal places or instrument resolution alone do not describe measurement uncertainty.

Used in these chapters · 26
Back to the term directory

Measurement-chain bandwidth

Related search terms: bandwidth

Bandwidth is the frequency range over which a measurement chain meets a specified response criterion, such as acceptable amplitude attenuation. The criterion must be stated.

Bandwidth is neither storage frequency nor measurement range. Rapidly stored but heavily smoothed data can have low useful bandwidth. The selected boundary must be specified, for example an amplitude ratio relative to the low-frequency signal. A first-order lag reaches a ratio of 1/√2 at ω = 1/τ. Recording values rapidly does not by itself give the physical measurement chain a correspondingly wide bandwidth.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

Mechanical face seal

A mechanical face seal seals a rotating shaft against a stationary housing using two closely interacting, very flat annular faces. One face rotates with the shaft while the other remains stationary. Closing forces and conditions within the narrow sealing gap affect friction, heat generation and leakage; secondary sealing elements close other possible paths.

The appropriate design depends on pressure, temperature, speed and the contacting fluids. Some arrangements require a dedicated supply around the seal faces. The term does not imply absolute zero leakage or maintenance-free service. Even suitable face materials can fail under incorrect alignment or loss of their intended supply. Replacement requires the complete installation specification, rather than shaft diameter alone.

Back to the term directory

Mechanistic model

A mechanistic model represents selected relationships through scientifically justified relations such as material balances, transport equations or kinetic expressions. It still contains simplifications and potentially estimated parameters.

A physically motivated equation does not guarantee that available observations identify every parameter uniquely. Mixing, reaction schemes and constant-property assumptions must suit the studied region. Predictions are checked against independent observations rather than accepted solely because of the model’s origin.

Foundations: Digital Twins for Advanced Manufacturing

Used in these chapters · 1
Back to the term directory

Median

The median is a middle value of an ordered distribution: at least half the values are no greater and at least half are no smaller. For an unweighted sample, the usual convention takes the middle observation for odd sample size and averages the two middle observations for even size.

Pellet-size comparisons must state whether objects, projected areas or another quantity are weighted. The resulting medians answer different questions. A median describes location, but neither variability nor rare large objects. Calculating a median also does not turn multiple image objects from one culture into independent biological replicates.

Foundations: Percentiles

Used in these chapters · 1
Back to the term directory

Membrane bioreactor

Related search terms: MBR

A membrane bioreactor combines a biological reaction with a membrane that provides a selected transport or separation function. Depending on the arrangement, the membrane retains cells, removes dissolved components or separates a gas supply from the culture liquid. The term therefore covers several physical designs and does not specify one particular cultivation mode.

An explanation must identify what should cross the membrane and what should remain behind. Area, material, pore structure or solution–diffusion behaviour, together with flow along the surface, determine its function. Deposits and concentration differences near the membrane can limit transport. A large nominal membrane area consequently does not guarantee a proportionally large effective exchange capacity.

Used in these chapters · 3
Back to the term directory

Membrane flux

Related search terms: flux, permeate flux

Volumetric membrane flux is permeate volume flow divided by the membrane area considered, commonly in L/(m²·h). It differs from total flow and from a substance-specific mass flux.

With parallel modules, the overall mean can conceal unequal loading. Area sizing needs the profile through the required total permeate quantity. Constant liquid flux demonstrates neither constant product passage, unchanged cell retention nor unchanged pressure demand.

Foundations: KrosFlo KR2i Tangential Flow Filtration System

Used in these chapters · 10
Back to the term directory

Membrane fouling

Related search terms: fouling, membrane deposition

Fouling describes changes in a membrane and its separation behaviour caused by deposition or interaction of material. Surface layers, adsorption or changes within accessible pores may contribute. The term covers several possible processes rather than one mechanism.

Falling flux or rising TMP is therefore a signal, not a unique causal diagnosis. Check viscosity, flow and measurement errors as well. Diagnosis distinguishes potentially reversible concentration polarisation from persistent deposits or other fouling contributions.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems

Used in these chapters · 11
Back to the term directory

Memorandum of understanding (MoU)

Related search terms: MoU, MOU

A memorandum of understanding records a shared understanding of intended cooperation. It may describe objectives, participating organisations, roles and next steps. The document title alone does not determine which obligations arise. Assessment requires its actual wording and legal context.

In biotechnology project reporting, a signed statement of intent should therefore be distinguished from a funded order, a constructed facility or demonstrated production performance. As an illustrative original document, the published 2025 memorandum between the United Kingdom and Colorado describes cooperation objectives and expressly states its own funding and legal status. Those provisions apply to that document; they are not a universal rule for every memorandum.

Foundations: UK–Colorado memorandum of understanding, 27 January 2025

Back to the term directory

Metabolism

Related search terms: Cellular metabolism

Metabolism is the interconnected network of chemical reactions within a cell. Degradative pathways provide energy and precursors, while biosynthetic pathways use them to construct cellular material and products. These directions are linked through shared intermediates, energy carriers and reducing equivalents. A change at one point can therefore affect distant parts of the network.

In a bioprocess, metabolism distributes consumed resources among growth, maintenance and product formation. High substrate consumption is consequently not an automatic sign of high desired productivity. Cells may instead release more carbon as carbon dioxide or by-products. Interpreting such shifts requires considering uptake, release and biomass development together rather than observing one metabolite in isolation.

Used in these chapters · 16
Back to the term directory

Metadata

Related search terms: data context

Metadata describe the context needed to understand and use data. They may include units, timing, instrument, sample, method and processing state. A number alone usually does not preserve that meaning.

A biomass result, for example, needs association with the correct sample and collection time. Exporting only a result column can make a later balance unusable. Required metadata depend on the purpose of the record and the workflow that must be reconstructed.

Foundations: Data Integrity and Compliance With Drug CGMP: Questions and Answers

Used in these chapters · 5
Back to the term directory

Method of moments

The method of moments estimates parameters by equating empirical sample moments to corresponding theoretical moments of the assumed model. For two unknown parameters, two independent moment equations may be used.

It can provide simple initial estimates for further fitting. The required moments must nevertheless exist and be sufficiently stable. High moments may be sensitive in small or strongly distorted process samples; a numerical solution does not establish the assumed distribution family.

Foundations: Method of moments

Back to the term directory

Metzner–Otto approach

The Metzner–Otto approach relates an effective average shear rate in a stirred system to impeller rotational frequency through a geometry-dependent factor. It supports appropriate rheological correlations.

This effective quantity is not a map of local shear rates or a direct cellular-damage threshold. Its factor and validity must match impeller geometry and flow regime. The relationship γ̇eff = ksN uses a geometry-dependent constant and rotational speed in s⁻¹. The resulting effective value is a model assignment, not a spatial measurement of every shear rate. It does not automatically describe local peaks or the time-varying exposure of an individual cell.

Foundations: Secretory Vesicle and Glucoamylase Distribution in Aspergillus niger and Macromorphology in Regions of Varying Shear Stress

Back to the term directory

Microalgae

Related search terms: Microalgal culture

Microalgae are microscopic algae that grow as individual cells, colonies or simple assemblies, depending on the species. Many perform photosynthesis, while some can additionally or alternatively use organic carbon sources. The collective term does not represent one uniform evolutionary group and is sometimes used more broadly in engineering. Cyanobacteria should nevertheless be distinguished biologically from eukaryotic algae.

Production targets include pigments, lipids, proteins and whole biomass. The desired composition depends strongly on cellular state. Nutrient limitation can increase the fraction of particular storage compounds while reducing the overall growth rate. A higher product content per gram of cells consequently does not necessarily mean more product per reactor per day.

Used in these chapters · 2
Back to the term directory

Microcarrier

Microcarriers are small particles that provide an attachment surface for cells within a moving liquid. Their material, surface chemistry, coating and porosity influence whether a particular cell type attaches and grows. They allow attachment-dependent cells to use an area that is not restricted to the outer walls of the culture vessel.

The particles need sufficient suspension and distribution without unacceptable cell damage from collisions or local flow. Surface area per gram is therefore only one design input; uniform colonisation, mass transfer and subsequent cell recovery also matter. A microcarrier does not turn an adherent cell into a biologically suspension-adapted cell. Even freely moving carriers can develop transport limitations or bridges of cells between particles.

Used in these chapters · 1
Back to the term directory

Mineralisation and ammonification

Related search terms: Nitrogen mineralisation, Ammonification

Mineralisation converts organically bound elements into inorganic forms. For nitrogen, release of ammonium from organic nitrogen is called ammonification.

The elemental nitrogen quantity is conserved while its form and subsequent reaction possibilities change. Ammonium can therefore rise without an external ammonium input. Alkalinity calculations additionally require the chosen chemical representation of the organic starting material.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Minimum fluidisation velocity

Minimum fluidisation velocity identifies incipient fluidisation under defined conditions. In an idealised force balance, fluid drag supports effective particle weight after buoyancy is accounted for.

Particle size, density, shape, fluid and distribution affect the value. Biofilm growth or attrition can change the operating state; no universal velocity follows. The value depends on particles, fluid, gravity and bed condition. A correlation established for a gas-solid bed cannot be transferred uncritically to a liquid bioreactor. Hysteresis or nonuniform flow can also affect the observed transition, so measurement procedure and the criterion defining onset should accompany the reported value.

Foundations: Fluidized Bed Reactors, Professional Reference Shelf

Used in these chapters · 1
Back to the term directory

Missense mutation

A missense mutation changes a codon so that a different amino acid is specified at the affected position. The reading frame is generally preserved. The functional effect can be large, small or undetectable under the conditions examined.

For a bioprocess product, sequence detection and functional assessment are therefore separate tasks. An unchanged total protein concentration does not exclude altered product properties. Conversely, finding an amino-acid substitution alone does not establish a particular change in stability, activity or suitability for the intended process.

Foundations: NHGRI: Missense mutation

Back to the term directory

Mixing time

Mixing time is the interval following a defined addition or disturbance until a specified homogeneity criterion is reached. For example, observed concentrations may be required to remain within a stated tolerance around their final value. Without that criterion and the addition and observation locations, a mixing-time value cannot be interpreted unambiguously.

The measure describes the response to a particular mixing experiment, rather than every distribution occurring during an active culture. Material added near an impeller may appear to mix faster than an unfavourably positioned addition. A few observation points can also miss slowly supplied regions. Scale-up and process design therefore require comparable experiments and consideration of mixing time relative to biological consumption times.

Used in these chapters · 15
Back to the term directory

Mixotrophy

Related search terms: Mixotrophic cultivation

Mixotrophy combines different nutritional strategies. In microalgal cultivation, it commonly refers to simultaneous use of light and an organic substrate, with inorganic carbon potentially contributing as well. Whether and to what extent an organism combines these options depends on species, strain and conditions. An illuminated culture supplied with sugar is therefore not automatically functioning mixotrophically.

Organic carbon can support growth but also changes respiration, gas exchange and the competitive conditions for accompanying organisms. Photosynthetic and heterotrophic activities may influence one another rather than simply adding together. Process assessment must establish the actual contributions of both resources. Biomass increase under illumination alone does not reveal how much of that increase is attributable to photosynthesis.

Used in these chapters · 1
Back to the term directory

Model drift

Model drift denotes a change in practical model performance or model-relevant relationships during use. Changes in inputs, measurement chains or biological relationships may cause it.

Larger prediction error alone does not distinguish these causes. Sensor replacement, new media and altered culture states require different investigations. Updates are controlled using documented data and renewed assessment; continued learning alone does not guarantee retained validity.

Foundations: Digital Twins for Advanced Manufacturing

Back to the term directory

Model matrix

Related search terms: Design matrix

The model matrix contains one row per observation and one column per estimated model term. It may include an intercept, interactions, squared terms and block indicators as well as factors.

Its rank determines whether the chosen coefficients are separately estimable. A table with many rows may still lack information if its columns are dependent. The design must therefore be checked against the model actually intended for analysis.

Foundations: Fractional factorial designs

Used in these chapters · 2
Back to the term directory

Moist heat

Related search terms: moist-heat sterilisation

Moist heat inactivates microorganisms through temperature-dependent damage to essential cellular components, particularly proteins, in the presence of water. During steam sterilisation, condensing steam transfers heat to cooler contact surfaces. Within a liquid, heat must reach the regions that warm most slowly. Water availability and the actual temperature history therefore strongly influence effectiveness.

A given pressure indicates temperature only under appropriate steam conditions. Trapped air, superheating and poor heat transfer can undermine that relationship and the treatment itself. The same nominal temperature under dry heat does not automatically produce the same inactivation. Medium components may also change during prolonged heating. The process must therefore provide sufficient microbial effectiveness while keeping thermal exposure acceptable for the material being treated.

Used in these chapters · 1
Back to the term directory

Molality

Molality is component amount per solvent mass, commonly mol/kg water. The denominator is neither total solution mass nor solution volume. These bases can differ appreciably for concentrated stocks.

Osmolality also uses solvent mass but describes osmotic behaviour. Chemical molality is therefore not automatically equal to osmolality; dissociation and nonideal behaviour affect the relationship. For example, 0.10 mol in 0.50 kg water gives 0.20 mol/kg, regardless of the final volume of the solution.

Foundations: 11.4 Colligative Properties

Used in these chapters · 2
Back to the term directory

Molar conductivity

Molar conductivity relates electrical conductivity to a specified electrolyte concentration using consistent units. It differs from the directly measured bulk conductivity.

It may vary with concentration, temperature and ionic environment. Linear salt determination from conductivity therefore needs suitable calibration and matrix. In complex media, ion contributions cannot uniquely identify one salt component without further information.

Foundations: Low Electrolytic Conductivity Standards

Back to the term directory

Molar flow rate

Related search terms: Molar flow

Molar flow rate is the amount of substance transported per unit time, for example mol/s or mmol/h. In a sufficiently uniform liquid stream, a component’s molar flow equals its amount concentration multiplied by volumetric flow. For an approximately ideal gas, total molar flow can be calculated as ṅ = p·V̇/(R·T), provided pressure, temperature and volume flow describe the same state.

A synthetic liquid stream of 12 L/h containing 0.20 mmol/L oxygen delivers 2.40 mmol/h oxygen. This is delivery, not yet biological consumption. Outlet transport, inventory change and other transfer paths complete the balance. Molar flows of different components also require their stoichiometric relationships: one mole of glucose, for example, contains six moles of carbon atoms.

Foundations: OpenStax Chemistry 2e: Gaseous substances and mixtures · OpenStax University Physics 1: Fluid dynamics

Used in these chapters · 8
Back to the term directory

Molar mass

Related search terms: molar masses

Molar mass M is mass per amount of substance, for example g/mol. It belongs to the specified chemical form. Anhydrous magnesium sulphate and its heptahydrate have different molar masses although each formula unit contains one magnesium atom.

Verify actual substance identity before converting a formulation. A precise value for the wrong hydrate gives the wrong amount. Assay, water basis and, where relevant, isotopic composition are separate specifications.

Foundations: 3.3 Molarity

Used in these chapters · 10
Back to the term directory

Molar mass distribution

Related search terms: Molecular weight distribution

Distribution of molar masses among molecules in a material, particularly polymers. One mean molar mass describes it only partially, and different averages may weight molecules differently.

Comparison requires method, calibration and the selected average. Products can share a mean while differing in distribution width. This differs from particle-size distribution: a particle can contain many molecules.

Foundations: Original polymer molecular-mass distribution manuscript

Back to the term directory

Molecular weight cut-off (MWCO)

Related search terms: MWCO, molecular-weight cutoff

MWCO is a nominal molecular-mass threshold characterised using test substances and a specified retention behaviour. It is expressed, for example, in daltons or kilodaltons, not as a pore-diameter length. Test definition and method belong with the value.

Actual product passage also depends on molecular form, interactions and conditions. MWCO is not a sharp universal boundary between completely passing and completely retained molecules. Verify selection through product passage and recovery measured in the intended process.

Foundations: Dialysis Methods for Protein Research · Protein preparation handbook

Used in these chapters · 3
Back to the term directory

Moment of inertia

Related search terms: rotational inertia

Moment of inertia describes mass distribution relative to a specified rotation axis. For discrete mass elements, J = Σmr², with an integral for a continuous body. Its unit is kg m². Equal total masses need not have equal moments of inertia because distance from the axis enters squared.

During acceleration of an impeller shaft, some power can be stored as rotational energy. For constant J, this contribution is Jω dω/dt. A torque measurement during a ramp therefore does not represent only instantaneous liquid power and friction losses. Axis, included components and operating condition belong in the measurement-boundary definition.

Foundations: Calculating Moments of Inertia

Used in these chapters · 1
Back to the term directory

Monochromatic light

Related search terms: Monochromatic

Monochromatic light has a single frequency or vacuum wavelength in the idealised model. Real sources described as monochromatic have a finite spectral width.

The simplification permits an unambiguous conversion between photon quantity and radiant energy using E = hc/λ. For a broadband lamp, contributions are instead summed over the spectrum. Equal energy at different wavelengths does not mean equal photon numbers or identical biological effectiveness.

Foundations: Fundamental Physical Constants — Complete Listing

Used in these chapters · 2
Back to the term directory

Monod kinetics

Related search terms: Monod equation, Half-saturation constant

Monod kinetics describes how specific growth rate rises with the concentration of a limiting substrate and approaches saturation: μ = μmax · S/(KS + S). μ and μmax may have units of h⁻¹; S and KS must share a concentration unit, such as g/L. At S = KS, the predicted rate is half of μmax.

This empirical approximation applies to a particular organism and conditions dominated by substrate limitation. It does not include substrate inhibition, changing cell composition or several coupled limitations. KS is therefore not a universal molecular property. A good mathematical fit also does not prove that the assumed mechanism alone governs the process.

Used in these chapters · 1
Back to the term directory

Moving-bed biofilm reactor

Related search terms: MBBR

An MBBR retains a substantial part of its active biomass as biofilm on moving carriers. Suitable retention devices prevent carriers leaving with the liquid effluent.

Carrier surface provides habitat but does not alone guarantee a specified removal performance. Accessible active area, film thickness, mass transfer and mixing affect conversion. Carrier fill and nominal specific area are therefore not translated into universal treatment capacity without performance evidence.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Multi-factor authentication (MFA)

Related search terms: MFA

Multi-factor authentication requires evidence from more than one distinct factor category, such as knowledge and possession. Two different passwords are therefore not automatically two factors. Implementation and recovery after loss of a factor must suit the application.

For remote access to bioreactor control, MFA can strengthen identity verification. It does not decide which equipment functions are permitted after login. Access rights, recording and an operationally suitable recovery route require separate arrangements.

Foundations: Multi Factor Authentication

Back to the term directory

Mycelium

Related search terms: mycelia

A mycelium is the network of hyphae forming a fungus. In liquid culture it can be dispersed, loosely aggregated or part of denser structures.

The term defines neither fixed density nor a particular flow curve. Process assessment therefore connects structural measurements with biomass, rheology and biological function. Engineering interpretation distinguishes freely dispersed filaments, connected aggregates and more compact pellets. Total biomass and visible network form provide different information. Image comparisons therefore need comparable sampling and presentation; a denser projection does not automatically demonstrate a higher biomass concentration in the original culture.

Foundations: A Library of Aspergillus niger Chassis Strains for Morphology Engineering

Used in these chapters · 2
Back to the term directory

Mycoplasma

Related search terms: mycoplasma contamination

Mycoplasma are very small bacteria without a rigid cell wall that can contaminate cell cultures without obvious signs. They can affect metabolism, growth and experimental results without producing conspicuous turbidity. This makes them practically different from many bacterial contaminants that become visible quickly. Contaminated cultures, raw materials and handling procedures are possible sources.

Clear culture fluid and an unremarkable routine bacterial test do not exclude mycoplasma. A filter label stating a pore size of 0.2 or 0.22 micrometres is also not general proof of mycoplasma retention. Control requires an approach matched to the risk and suitable specific detection methods. Antibiotics may conceal contamination and cannot replace clean starting cultures, controlled handling and justified testing intervals.

Used in these chapters · 2
Back to the term directory

N

Net biomass formation

Net biomass formation is the biomass generated within a balance boundary after concurrent degradation losses. An inventory balance calculates it as inventory increase plus output minus input.

Harvest may contain cells already present at the beginning and therefore is not automatically newly formed biomass. Gross synthesis and concurrent respiration or decay cannot be separately determined from a net inventory balance alone. Samples and other withdrawals are explicitly included.

Used in these chapters · 1
Back to the term directory

Net growth rate

Related search terms: Net increase

Relative change per time in an explicitly defined biomass or cell quantity after appropriate treatment of physical inputs and outputs. For viable cells it may represent proliferation minus loss from the counted class.

A constant μ gives M(t) = M₀exp(μt) in the simple model, with units such as h⁻¹. It is not automatically maximal growth or pure cell-division rate. With variable volume, concentration slope cannot be used as inventory growth without correction.

Foundations: Lecture13: Microbial growth and product formation kinetics

Used in these chapters · 8
Back to the term directory

Net present value

Related search terms: NPV

Net present value is the sum of cash inflows and outflows discounted to a common date. A positive result indicates a positive balance within the chosen cash-flow series and discount rate.

For an additional production line, saleable amounts, costs, ramp-up timing and residual values are explicit assumptions. Net present value is not guaranteed profit. Sensitivity calculations show which quantity or timing changes could alter the project decision.

Foundations: 11.4 Discounted Cash Flow Models

Back to the term directory

Neutralisation

Related search terms: neutralization

Here, neutralisation means acid–base reaction through proton transfer. Amount relationships depend on the reactions and equivalents involved. The final pH need not be seven because remaining species have their own equilibria.

During NaOH addition, hydroxide can be consumed while sodium remains in the liquid inventory. The added particle effect is therefore not simply twice the dosed NaOH amount regardless of reaction.

Foundations: 14.6 Buffers

Used in these chapters · 4
Back to the term directory

Nitrification

Nitrification is biological oxidation of reduced inorganic nitrogen; conventional wastewater analysis considers ammonium conversion through nitrite to nitrate. Complete oxidation consumes oxygen and decreases alkalinity.

A purely stoichiometric ammonium-to-nitrate balance without biomass synthesis requires 64/14 kg O₂ per kg N. Real overall balances additionally include assimilation and other conversions. Nitrification changes nitrogen form but does not itself remove nitrogen from the plant.

Foundations: Nutrient Control Design Manual

Used in these chapters · 4
Back to the term directory

Nitrogen source

Related search terms: Nitrogen nutrient

A nitrogen source supplies nitrogen for proteins, nucleic acids and other cellular components. Depending on the organism, suitable sources include ammonium, nitrate or organic nitrogen compounds. Suitability depends on uptake pathways and metabolism. Different sources can impose different energy and reducing-power requirements and can influence the culture’s pH trajectory.

Nitrogen shortage can restrict proliferation and also change biomass composition. This may favour particular storage products while reducing protein production. A fixed ratio of added carbon to nitrogen does not necessarily describe the ratio actually consumed. With complex raw materials especially, interpretation must account for nutrient availability and the other nutrients contributed by the same ingredient.

Used in these chapters · 2
Back to the term directory

Nominal volume

Nominal volume is a size designation assigned to a bioreactor by a manufacturer or specification. Without an accompanying definition, it cannot be assumed to equal maximum working volume, geometric internal volume or the quantity of liquid actually present. Different product families may attach similar size labels to different reference quantities.

A technical request should therefore state the required liquid volume explicitly, for example the usable culture volume at the beginning and end of a process. The nominal value helps identify a size class but is insufficient for calculating output, oxygen supply or space requirements. Drawings, the working-volume range and relevant operating conditions turn the label into a useful basis for comparing equipment.

Used in these chapters · 4
Back to the term directory

Non-coding DNA

Non-coding DNA denotes genomic regions that do not directly specify a protein’s amino-acid sequence. Such regions can include regulatory elements. Non-coding therefore does not mean unnecessary or biologically ineffective.

Assessing a production construct may require more than examining its protein-coding region. Genomic context and regulatory elements can matter for expression. This does not, however, establish a specific cause of altered production; the proposed function needs to be connected to suitable experimental evidence.

Foundations: NHGRI: Non-coding DNA

Back to the term directory

Non-condensable gas

Related search terms: noncondensable gas, non-condensable gases

A non-condensable gas does not condense like water vapour under the process conditions considered. Air contributes to total pressure in a steam-air mixture without supplying the same condensation heat.

Local accumulation may affect heat transfer and air removal. Total measured pressure is not automatically water-vapour partial pressure. The designation is condition-dependent, not a claim that the substance can never condense.

Foundations: Steam Quality

Used in these chapters · 2
Back to the term directory

Non-Newtonian flow behaviour

Related search terms: Non-Newtonian rheology, Apparent viscosity

Non-Newtonian flow behaviour occurs when the relationship between shear stress and shear rate cannot be described by one constant viscosity. A liquid may become apparently less viscous as shear rate increases, exhibit a yield stress or change behaviour with the duration of loading. These are distinct phenomena and need not occur together.

In a bioreactor, slowly and rapidly moving regions can consequently exhibit different apparent viscosities. Vigorous flow near the impeller may then coexist with poor motion elsewhere. Suitable flow curves, and sometimes time-dependent measurements, provide more information than one viscosity value. A fitted mathematical model applies within its investigated loading range and should not be treated as a universal material description.

Used in these chapters · 9
Back to the term directory

Non-repudiation

Related search terms: non-repudiation

Non-repudiation concerns technical and organisational properties supporting verifiable evidence of an action or data origin. Digital signatures can contribute. The actual claim depends on identity association, key management and preserved records.

For process approvals, a visible name on a screen is therefore insufficient on its own. The relationship between person, action and record must remain assessable. Technical evidence does not automatically create every possible legal effect; that depends on the application context.

Foundations: Non Repudiation

Back to the term directory

Nonsense mutation

A nonsense mutation introduces a premature stop signal into a previously continuing coding sequence. Translation can consequently produce a shortened protein chain. Whether that chain is detectable, and in what amount, also depends on how the cell handles the affected RNA and protein.

A reduced product titre does not establish this mechanism. Investigation connects sequence findings, transcript measurements and product identity using appropriate methods. The position matters: the functional consequence of a very early interruption can differ substantially from that of an interruption close to the normal end.

Foundations: NHGRI: Nonsense mutation

Back to the term directory

Normal distribution

Related search terms: Gaussian distribution

The normal distribution is a continuous symmetric distribution specified by mean μ and positive standard deviation σ. Its density is proportional to exp[−(x − μ)²/(2σ²)].

It may suit certain measurement or process deviations, but merely using an average does not establish it. Bounded, strongly asymmetric or correlated data require separate assessment. Normally distributed residuals are also different from normally distributed raw observations.

Foundations: Normal distribution · Testing normality of random errors

Used in these chapters · 2
Back to the term directory

Nucleation

Nucleation is the formation of small regions of a new phase from which, for example, a crystal can grow. Homogeneous nucleation starts within the parent phase; heterogeneous nucleation is assisted by an existing interface. Supersaturation alone therefore does not determine when visible precipitation starts.

A concentrated medium may initially look clear and develop particles later. Mixing history, residence time, temperature and available surfaces consequently belong in the investigation. Here the term concerns physical phase formation, not microbial growth. Visible turbidity proves neither the presence nor the absence of microorganisms.

Foundations: Salt crystallization and deliquescence triggered by humidity cycles in nanopores · 11.3 Solubility

Used in these chapters · 1
Back to the term directory

Nucleosome

A nucleosome is a basic unit of eukaryotic chromatin: a segment of DNA is wrapped around a core of histone proteins. Many such units help organise the genome. Accessibility of DNA for cellular use can change and is not determined by the base sequence alone.

This provides useful context for cell-line studies. Demonstrating retention of a production sequence and demonstrating an unchanged expression state are different claims. A relationship between chromatin organisation and production requires experimental investigation; ordinary reactor measurements do not directly reveal nucleosome organisation.

Foundations: NHGRI: Nucleosome

Back to the term directory

Nucleotide

Related search terms: Nucleotides

A building block consisting of a nitrogenous base, sugar and one or more phosphate groups. Linked nucleotide residues form DNA and RNA, whose sugars and bases differ.

Nucleotides also have other biological roles, including activated metabolic components. A nucleotide is neither a base alone nor a whole gene. Quantity reporting requires the chemical form and amount-of-substance basis for correct mass conversion.

Foundations: Nucleotide

Back to the term directory

Null hypothesis

Related search terms: H₀

A null hypothesis is the explicitly specified statistical assumption under which a test’s reference distribution and p-value are calculated. It may express, for example, a zero effect or a particular model relationship.

Failure to reject it does not prove it true or establish practical equivalence of two processes. The conclusion depends on data quantity, variation and the appropriate experimental unit. An intended equivalence question requires predefined scientific margins and a suitable comparison.

Foundations: Testing missing or misspecified model terms

Back to the term directory

O

Observability

Observability asks whether the initial state of a specified dynamic model can be uniquely determined from known input and output histories. The model and its parameters are assumed given. For linear time-invariant models, an observability matrix formed from output and state matrices provides a formal test.

Measuring total inventory in a closed two-zone system can conceal different internal distributions, while a suitable local measurement may reveal additional state information. Formal observability does not guarantee robust reconstruction with noise, slow sensors or uncertain parameters. It also differs from parameter identifiability and diagnosis of a particular fault cause; each question has separate assumptions and requires its own assessment.

Foundations: Lectures on Dynamic Systems and Control, Chapter 24: Observability

Used in these chapters · 2
Back to the term directory

Off-gas analysis

Off-gas analysis determines components of the gas leaving a bioreactor, commonly oxygen and carbon dioxide. Suitable analysers measure their fractions; additional inlet and outlet information allows gas balances and interpretation of metabolic activity. Samples normally travel through a line to the instrument.

A concentration alone is not a production or consumption rate. Calculating rates requires correct gas flows, reference conditions and, where necessary, water and inert-gas balances. Condensate, leaks and changing aeration affect either the signal or its interpretation. Headspace and sampling lines also delay observation of rapid events. The time of an off-gas peak therefore need not match the original biological event in the liquid phase.

Used in these chapters · 1
Back to the term directory

Offline measurement

Offline measurement analyses a separately collected sample outside the directly connected process-measurement system, commonly in a laboratory. Detailed chromatographic analysis and product-quality testing are examples. The method is organisationally separated from the operating measurement and control loop and usually involves transport, preparation and later transfer of results.

Offline analysis offers a broader range of methods and can provide references for faster process measurements. It is not automatically more accurate: representativeness, sample stability and the analytical method remain decisive. Delayed results must not be treated as current values in dynamic cultures. Model development and sensor comparison require assignment to the sampling time, with documented storage and preparation.

Back to the term directory

Oligonucleotide primer

Short nucleic-acid segment that binds a suitable template and can initiate polymerase extension. Binding location and direction define the interrogated region.

A successful reaction does not automatically establish specificity. Identity testing requires understanding which variants the primers distinguish or detect together.

Foundations: Addgene

Back to the term directory

Online measurement

In the narrower process-analytical sense, online measurement diverts a stream from the process to a connected analyser. Return to the process is possible but is not essential to the definition. Culture liquid may, for example, be withdrawn automatically, analysed outside the reactor and discarded where sterile return is not intended.

Connection enables repeated or continuous results without manual sample transport. Measurement intervals, transport delay and preparation still matter. A process connection guarantees neither real-time performance nor representative results. Returning material also requires consideration of measurement-induced changes and protection of the sterile culture. Because online often serves as a broader term, the connection, sample path and timing should be documented.

Back to the term directory

OPC Unified Architecture (OPC UA)

Related search terms: OPC UA, OPC-UA

OPC UA is an architecture for structured information exchange between technical systems. It defines communication services and information models; individual products provide particular capabilities. The acronym alone therefore does not establish which measurements, events or actions are actually accessible.

For a bioreactor, assess server, client, information model, units, timestamps and access rights together. A working connection does not demonstrate complete semantic agreement. Required data exports and behaviour during communication interruptions belong in the actual integration assessment.

Foundations: OPC Unified Architecture · Certification overview and benefits

Used in these chapters · 3
Back to the term directory

Open reading frame (ORF)

An open reading frame is a sequence region interpreted in a specified triplet pattern without an intervening stop signal. It may form part of a protein-coding sequence. Its computational existence alone does not prove that the cell reads the region or produces a stable protein.

For production constructs, sequence prediction and experimentally demonstrated expression are therefore documented separately. Strand direction, genetic code and the use of genomic or processed sequence must be explicit. Suitable RNA or protein evidence is needed to evaluate the biological significance of the predicted region.

Foundations: NHGRI: Open reading frame (ORF)

Back to the term directory

Operating envelope

Related search terms: Operating window

An operating envelope is a stated range of conditions within which a process performs adequately for a defined purpose. It can involve interacting quantities such as working volume, agitation, aeration and heat removal. Separate permissible minima and maxima do not establish that every combination within them is suitable.

If a synthetic process reaches high biomass only with sufficient cooling, cooling capacity is part of the envelope’s conditions. A list of agitation speeds would be incomplete. Records should distinguish tested combinations, success criteria and the boundary between observed results and model predictions. A technical operating envelope is not automatically a regulator-approved design space or permission to operate a particular installation.

Foundations: Noor et al.: The protein cost of metabolic fluxes

Used in these chapters · 7
Back to the term directory

Operating expenditure (OPEX)

Related search terms: OPEX, operating costs

OPEX describes running expenditure within the defined assessment boundary. An engineering calculation may include staff, media, energy, consumables and service. The exact boundary must match the calculation.

In bioprocessing, many items depend on batch count, duration or product quantity, while others occur even at low utilisation. An annual figure without its operating programme is therefore only partly comparable. Avoid counting investment and running expenditure twice.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 5
Back to the term directory

Operating leverage

Related search terms: operating leverage

Operating leverage describes the sensitivity of operating profit to sales changes. In a linear cost model, local leverage is total contribution margin divided by operating profit. Near zero profit the ratio becomes very large or undefined.

A plant with substantial fixed costs can consequently be sensitive to low utilisation. The approximation assumes unchanged prices, variable unit costs and product mix, among other conditions. Capacity steps or additional shifts change the model.

Foundations: 3.5 Margin of Safety and Operating Leverage

Back to the term directory

Operational qualification (OQ)

Related search terms: operational qualification

Operational qualification documents whether installed equipment functions as intended throughout its specified operating range. It includes relevant functions, boundary conditions and responses to selected failures. For a bioreactor, valve sequences, alarms and behaviour after loss of a utility may be important. Tests follow requirements and risks rather than an arbitrary collection of screen functions.

Successful normal operation may be insufficient: an ineffective interlock can remain hidden until a selected fault condition is examined. OQ is nevertheless not an unrestricted stress test beyond permitted equipment limits. Passing functional tests also does not establish consistent product quality in the later biological process. Acceptance criteria and permitted operating limits should be defined beforehand so results are not reinterpreted afterwards to make them fit.

Used in these chapters · 3
Back to the term directory

Opportunity cost

Related search terms: opportunity costs

Opportunity cost is the benefit forgone from the best genuinely available alternative displaced by a decision. An existing equipment slot can therefore have economic value even without a new purchase invoice.

The alternative must be realistically available and appropriately bounded. Theoretical demand without suitable production capability is not automatically forgone benefit. Bioprocess evaluation considers displaced batches, scarce time and actual product requirements together.

Foundations: 10.1 Identify Relevant Information for Decision-Making

Used in these chapters · 1
Back to the term directory

Optical density

Related search terms: OD, OD₆₀₀

Optical density describes attenuation of a light beam by a sample. Formally, OD = −log₁₀(I/I₀), where I is transmitted intensity and I₀ is reference intensity. Scattering, together with any absorption, contributes to the signal in cell suspensions. A designation such as OD₆₀₀ specifies a measurement wavelength of 600 nm.

OD provides a rapid indirect biomass estimate but neither counts cells nor reliably separates living from dead cells. Cell size, morphology, medium and optical geometry affect the relationship. High turbidity often requires dilution into a verified measuring range. Consequently, no universal conversion factor to g/L or cells/mL exists; the correlation must suit the organism, instrument and conditions.

Used in these chapters · 5
Back to the term directory

Optical depth

Related search terms: Optical thickness

Optical depth is the dimensionless path integral of an appropriate attenuation coefficient. For constant k and path length L, τ = kL; transmission is exp(−τ) in the simple directional exponential model.

Equal optical depth does not guarantee the same local light field: differently ordered layers may have identical exit values but different depth averages. In scattering media, interpretation depends on whether extinction, absorption or an empirical coefficient was used.

Foundations: Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 2
Back to the term directory

Origin of replication

Related search terms: ori

A DNA region at which replication of a suitable DNA molecule is initiated. In plasmids it helps determine which hosts can propagate the construct.

An origin is not a promoter. Successful plasmid propagation therefore does not establish expression or quality of the intended product.

Foundations: Addgene

Back to the term directory

Orthogonal design

Related search terms: Orthogonality

Orthogonality in an experimental model refers to model columns whose inner product is zero. With suitable balanced coding, it facilitates separate estimation of certain effects.

The property depends on the runs actually observed and the model. A missing run may make originally orthogonal columns correlated. Matrix orthogonality means neither biological independence of factors nor absence of real interactions.

Foundations: Two-level full factorial designs

Used in these chapters · 1
Back to the term directory

Oscillatory strain sweep

An oscillatory strain sweep varies deformation amplitude at specified frequency. It investigates the range over which response remains approximately linear.

High amplitudes can change sample state. Consequently record sequence, holding times and any renewed preparation when comparing measurements. Moduli are evaluated against the imposed amplitude. Approximate constancy helps select a region for subsequent linear measurements. At very small amplitudes, instrument signal limitations may dominate; a useful amplitude therefore lies within an experimentally assessed range rather than being chosen arbitrarily close to zero.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

Osmolality

Related search terms: mOsm/kg

Osmolality describes the effective concentration of osmotically active dissolved particles relative to the mass of solvent. It is expressed in osmol/kg, usually mOsm/kg for culture media. Osmolarity instead refers to solution volume, for example osmol/L. These terms and their numerical values are not universally interchangeable. Dissociation and departures from ideal solution behaviour affect the resulting osmotic effect.

In cell culture, concentrated feeds, salt or base additions and water evaporation can change osmolality, influencing cell volume, growth and viability. Freezing-point depression provides one measurement principle. Suitable ranges depend on the cell line, medium and process phase. Identical measured osmolality establishes neither identical medium composition nor equivalent biological compatibility.

Used in these chapters · 11
Back to the term directory

Osmolarity

Related search terms: osmotic concentration

Osmolarity, or osmotic concentration, expresses osmotic particle behaviour per solution volume, commonly mOsm/L. Osmolality uses solvent mass. Values may be similar for dilute aqueous solutions but are not identical by definition.

Conversion requires enough information about density and solvent fraction. A medium result in mOsm/kg must not silently be relabelled mOsm/L. Heating can change solution volume while solute amount and solvent mass remain unchanged; this is another reason why the reference quantity belongs with the value.

Foundations: 11.4 Colligative Properties

Used in these chapters · 3
Back to the term directory

Osmotic pressure

Osmotic pressure is the pressure difference needed, under defined conditions, to counter net solvent movement driven by differing solvent activity across a suitable semipermeable membrane. In the dilute ideal limit, the van ’t Hoff relationship links it to particle concentration and temperature.

Biological membranes require permeability and timescale to be considered. Measuring osmolality characterises the solution without determining the full dynamic state of a living cell.

Foundations: 11.4 Colligative Properties

Back to the term directory

Overall heat-transfer coefficient

Related search terms: U-value for heat transfer

The overall heat-transfer coefficient U combines the resistances to heat transport between two fluids separated by a wall. Its units are W/(m²·K), and together with area and temperature difference it relates to the transferable heat rate. Fluid-side boundary layers, wall material and additional surface layers all contribute to the overall resistance.

U is consequently not simply a material property. A highly conductive wall may offer little benefit if a poorly moving liquid layer dominates resistance. Flow changes and deposits can also alter the effective coefficient. Calculations must identify the reference area and applicable operating conditions. A local heat-transfer coefficient on only one side of the wall is distinct from this overall quantity.

Used in these chapters · 1
Back to the term directory

Overflow metabolism

Related search terms: Metabolic overflow

Overflow metabolism redirects consumed resources towards excreted intermediates or by-products even though more complete utilisation would in principle be possible. Under the prevailing conditions, uptake does not match the capacity of downstream metabolic pathways. Regulation and the allocation of cellular resources also contribute. Engineering examples include acetate formation by certain bacteria and aerobic ethanol formation by certain yeasts.

Overflow is therefore not synonymous with oxygen shortage. It can occur with adequate dissolved oxygen and lower biomass yield. Reducing substrate load may help, but the effect must be weighed against the desired production rate. Whether the excreted compound is undesirable also depends on the product that the process is intended to manufacture.

Back to the term directory

Oxygen equivalent

Related search terms: O₂ equivalent

An oxygen equivalent expresses an oxidation or reduction capacity as the corresponding O₂ mass. It is based on equal electron transfer; molecular oxygen need not actually be consumed.

Nitrate reduction can use part of an organic electron donor that would otherwise be oxidised aerobically. This credit is counted only once. Oxygen equivalent, gaseous O₂ supplied and oxygen actually transferred into liquid are different quantities.

Foundations: Nutrient Control Design Manual

Used in these chapters · 2
Back to the term directory

Oxygen transfer rate

Related search terms: OTR

Oxygen transfer rate, OTR, is the amount of oxygen transferred into the liquid per unit time, commonly normalised to liquid volume. A simplified, well-mixed model gives OTR = kLa · (c* − c). With kLa in h⁻¹ and concentrations in mmol/L, OTR is in mmol/(L·h). Here c* is the equilibrium concentration under the relevant gas conditions and c is the current dissolved concentration.

This separates transport capability from driving force. A high kLa can still produce a low instantaneous OTR when the concentration difference is small. Transfer is also not automatically equal to consumption: the two differ when dissolved oxygen inventory changes. A claimed maximum OTR therefore requires its conditions and assumptions.

Used in these chapters · 5
Back to the term directory

Oxygen uptake rate

Related search terms: OUR

Oxygen uptake rate, OUR, describes the oxygen consumed by a culture per unit time. Its volumetric form may be expressed in mmol/(L·h). If a biomass-specific uptake rate qO₂ is based on biomass mass, OUR = qO₂ · X, where X is biomass concentration. The biomass basis must match the units used for the specific rate.

OUR represents biological demand, whereas OTR describes physical delivery. At constant liquid volume and without other oxygen streams, dc/dt = OTR − OUR. Equality therefore requires an unchanged dissolved oxygen inventory. Increasing OUR can reflect more biomass, greater specific activity or both; it does not distinguish these causes without additional information about culture development.

Used in these chapters · 10
Back to the term directory

P

p-value

A p-value is the probability, under a specified null hypothesis and its model, of a test result at least as extreme as that observed. The test defines which results count as extreme.

It is neither the probability that the null hypothesis is true nor the magnitude of a process effect. Data-dependent selection among many tests can change its interpretation. Effect size, uncertainty, design and practical requirements therefore belong together in the decision.

Foundations: Testing missing or misspecified model terms

Back to the term directory

Packed-bed bioreactor

Related search terms: Fixed-bed bioreactor

A packed-bed bioreactor retains cells or biocatalysts on or within a largely stationary support material. Liquid passes through the spaces in the bed and supplies the retained biomass. A substantial growth surface can therefore coexist with relatively few freely suspended cells in the surrounding liquid.

The useful surface is the portion that receives adequate supply, rather than simply the total area quoted for the carrier. Uneven flow, compaction and increasing biomass coverage can create preferential channels and poorly supplied regions. An oxygen concentration measured outside the bed consequently does not demonstrate uniform conditions inside it. Bed volume, liquid volume and accessible growth area must be distinguished when comparing systems.

Used in these chapters · 5
Back to the term directory

Paired comparison

A paired comparison associates each observation under one condition with a scientifically matched observation under the other. Analysis may be based on differences within these pairs.

Reactor runs may, for example, be paired within the same development block. Difference variance includes covariance between the two values. The number of independent pairs and variation of their differences are decisive; similar row numbers alone do not justify pairing.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 3
Back to the term directory

Parameter identifiability

Related search terms: identifiability, Identifiability

Identifiability concerns whether model parameters can be uniquely determined from available inputs and observations. Structural ambiguity persists even without noise; practical uncertainty additionally reflects limited data quality.

A numerical optimum does not prove uniqueness. Independent sensor characterisation, additional observation locations or different excitations can supply missing information. Structural non-identifiability may persist even with ideal noise-free data. Practical difficulty can additionally arise from noise, short experiments or similar parameter effects. For two cascaded lags, an independent sensor measurement can help assign the observed time constants to the correct physical processes rather than merely fit their combined response.

Foundations: Lesson 4: Two Tanks in Series · Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 9
Back to the term directory

Partial derivative

A partial derivative describes a function’s local rate of change with respect to one variable while its other independent variables are held fixed. It therefore depends on the chosen function and evaluation point.

For m = V·c, for example, ∂m/∂c = V at constant V. Such derivatives serve as sensitivity coefficients in uncertainty models. If inputs change together, an isolated derivative does not describe the entire change path; their dependencies must also be accounted for.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Back to the term directory

Partial pressure

Partial pressure is a component’s pressure contribution in a gas mixture. For an ideal-gas mixture, pᵢ = yᵢ·p, where yᵢ is mole fraction and p is absolute total pressure. The partial pressures sum to the total pressure. Fractions must consistently use the same dry or wet gas basis.

An assumed oxygen fraction of 0.20 at 1.20 bar absolute gives an oxygen partial pressure of 0.24 bar. Substituting gauge pressure or accidentally excluding water from the fraction basis produces an incorrect result. Partial pressure describes the gas phase. Calculating an equilibrium liquid concentration additionally requires a suitable solubility model, temperature and medium composition.

Foundations: OpenStax Chemistry 2e: Gaseous substances and mixtures

Used in these chapters · 4
Back to the term directory

Particle attrition

Related search terms: attrition

Particle attrition is mechanical loss of smaller constituents from particles or carriers. It can generate fines, alter size distributions and cause material loss.

Attrition differs from growth, cell division and biological dissolution. Assessment separates material inventory, shape and biological activity while considering contact locations, duration and repeated loading. Generated fines can change discharge, retention and pressure drop. A shifted mean size alone cannot reliably distinguish attrition from breakage, growth or selective sampling. An appropriate investigation therefore considers size distribution and mass balance and checks whether specimen preparation itself introduces additional mechanical changes before measurement.

Foundations: Secretory Vesicle and Glucoamylase Distribution in Aspergillus niger and Macromorphology in Regions of Varying Shear Stress

Used in these chapters · 1
Back to the term directory

Passage number

Related search terms: Subculture number

Passage number records how often a culture has been transferred into a new cultivation stage and propagated further. It captures part of the culture history and helps design experiments using comparable starting material. It is not directly equivalent to the number of cell divisions: when cultures diluted to different extents are expanded back to a comparable target cell number, the more strongly diluted culture requires more population doublings.

Meaningful comparisons therefore also require the split ratio, culture duration and, where relevant, cumulative population doublings. These details matter when cell functions change during continued expansion. A low passage number is not an independent certificate of quality. The essential question is whether the required characteristics remain present throughout the intended cultivation history.

Used in these chapters · 5
Back to the term directory

Passivation

Related search terms: stainless-steel passivation

Passivation supports the formation or restoration of a protective, chromium-rich surface layer on stainless steel. Suitable chemical treatment can remove free-iron contamination from the surface, among other effects. It requires an appropriate alloy and correctly prepared surface. The objective is suitable corrosion resistance under the intended service conditions.

Passivation is neither an additional thick coating nor a method for correcting poor welds. It also does not automatically remove every deposit or repair deep corrosion damage. Appropriate treatment depends on surface condition, alloy and application. Subsequent treatment, rinsing and verification form part of the overall procedure. Even a well-passivated surface can corrode when exposed to unsuitable media, chloride contamination or unfavourable crevice conditions.

Back to the term directory

Patch management

Related search terms: patch management

Patch management organises the handling of software corrections and updates. It includes identifying relevant notices, assessing the affected version, suitable deployment and checking the result. An automatic download does not cover the complete process.

For bioreactor control, relate necessary changes to effects on running processes and data. Appropriate testing and a planned transition support operability. The term implies neither indefinite avoidance of updates nor unassessed updating during cultivation.

Foundations: Patch Management

Back to the term directory

Peak load

Related search terms: peak load

Peak load is the greatest demand within a defined period at a stated time resolution. A second-by-second maximum and a quarter-hour average are different metrics.

Utilities serving multiple bioreactors must add simultaneous demands. A short peak can violate pressure or temperature limits despite sufficient daily energy. Storage helps only with adequate initial content, available discharge power and subsequent recharging.

Foundations: Steam Accumulators

Back to the term directory

Péclet number

The mass-transfer Péclet number Pe = UL/D compares advection with molecular diffusion using velocity U, length L and diffusivity D.

A large vessel-scale value does not make diffusion negligible at every interface. Thermal applications use thermal diffusivity instead of D, so the transported quantity must be stated. The ratio can also be read as diffusion time L²/D divided by advection time L/U, using the same characteristic length in both. Very slowly moving local regions may differ greatly from vessel averages. The selected group should therefore correspond to the actual transport path being examined.

Foundations: A simulation modeling framework for fluid motion and transport in a rocking bioreactor

Back to the term directory

Performance qualification (PQ)

Related search terms: performance qualification

Performance qualification documents that equipment performs effectively and repeatably under conditions representative of its intended application. Suitable materials or justified representative substitutes are used. Tests address the required performance range and relevant challenging cases. For a reactor, behaviour at the intended fill volume may be more meaningful than a test with only a small quantity of water.

A substitute must adequately represent the properties that matter. Water does not automatically represent a viscous or foaming culture. PQ differs from operational qualification through its closer connection to the intended application, but it is not necessarily identical to complete process validation. The qualification plan should make the boundary clear so that neither evidence gaps nor unjustified duplicate testing result.

Used in these chapters · 1
Back to the term directory

Perfusion

Perfusion continuously supplies fresh medium and removes spent medium while a retention device keeps a substantial proportion of cells within the system. Liquid and cells can consequently have different residence times. Dissolved products may be harvested continuously if they pass through the selected retention device sufficiently well.

The operating mode supports high cell densities and can shorten the exposure of sensitive products to culture conditions. It also increases demands on medium supply, filter operation and material balances. A high exchange rate alone describes neither cellular nutrient supply nor productivity; cell number and medium composition also matter. Nutrient limitation, carbon dioxide accumulation and unintended product retention can still occur.

Used in these chapters · 23
Back to the term directory

Permeate

Related search terms: permeate stream

Permeate is liquid that has passed through a membrane. Its dissolved substances, particles and product forms depend on separation duty and conditions. It may be the desired harvest or a loss stream requiring examination.

Low cell content does not by itself make permeate sterile or product-free. Determine quantity and composition appropriately. A time-resolved harvest balance integrates actual permeate flow with its corresponding concentration rather than using only an end-of-run sample.

Foundations: KrosFlo KR2i Tangential Flow Filtration System · Protein preparation handbook

Used in these chapters · 10
Back to the term directory

pH measurement

pH measurement indicates how acidic or basic the aqueous culture liquid is. Conventional glass electrodes convert a potential difference relative to a reference electrode, which depends on hydrogen ion activity, into a pH reading. Appropriate calibration and measurement temperature are required; alternative optical methods use pH-dependent dye responses.

The measurement supports acid, base or carbon dioxide addition. Even a correctly calibrated probe can report an unrepresentative local value, for example immediately beside an addition point. Temperature compensation does not automatically correct the temperature-dependent chemistry of the medium itself. A cooled, degassed laboratory sample must therefore not be treated as an unchanged reference for the reactor reading.

Used in these chapters · 31
Back to the term directory

pH-stat feeding

pH-stat feeding uses a reproducible metabolic pH response to control nutrient addition. In some cultures, substrate exhaustion changes the production or uptake of acidic or alkaline compounds sufficiently for a pH trend to serve as a feeding signal. The direction and size of this response depend on the process.

This strategy differs from ordinary pH control using acid and base. Carbon dioxide removal, buffer capacity, nitrogen source and corrective additions influence the same signal and may interfere with interpretation. A pH-stat strategy therefore requires experiments supported by substrate analysis. A stable controlled pH alone demonstrates neither adequate nutrient availability nor an unchanged composition of the culture liquid.

Back to the term directory

Phase shift

Phase shift is the relative timing of periodic signals, expressed as an angle or fraction of a period. The same time interval corresponds to different angles at different frequencies.

Sensor filtering and transport can cause phase shifts. Apparently opposing measurements therefore require assessment of frequency and delay before interpretation. A pure delay td produces phase shift −ωtd at angular frequency ω. A dynamic filter generally does not have a frequency-independent delay time. Shifting an entire time axis by one interval therefore does not correct every phase change introduced by a measurement chain.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

Phenotype

Related search terms: Cell phenotype

The phenotype comprises the observable characteristics of a cell or organism, including morphology, metabolic behaviour, growth characteristics and expression of particular proteins. It results from the interaction between genetic information and the environment. Cells with the same ancestry can therefore show different phenotypes under different cultivation conditions without necessarily acquiring a new mutation.

For a bioprocess, the relevant phenotype is the one that supports the intended function. Continued presence of a production gene, for example, does not guarantee an unchanged product formation rate. Medium composition, cell contacts or stress can alter gene activity and cellular behaviour. Culture assessment should consequently distinguish ancestry from functional characteristics before examining how the two are related.

Used in these chapters · 2
Back to the term directory

Photoacclimation

Related search terms: Light acclimation

Photoacclimation is the physiological adjustment of a photosynthetic culture to its light environment. Cells may change pigment quantities, the organisation of light-harvesting systems and protective mechanisms. After an adjustment period, the same cells can therefore respond differently to a given illumination than immediately after a change. Acclimation differs from an instantaneous, purely physical light effect.

Light history consequently matters in cultivation comparisons. A culture expanded under weak illumination may respond more sensitively to a strong increase than already acclimated cells. Pigment changes also alter the light distribution inside the reactor. More intense colour does not, however, automatically indicate a higher biomass concentration. Physiological adjustment and changes in biomass quantity must be distinguished.

Used in these chapters · 2
Back to the term directory

Photoautotrophy

Related search terms: Photoautotrophic cultivation

In photoautotrophy, energy comes mainly from light and the carbon used for biomass comes from inorganic sources such as carbon dioxide or bicarbonate. Cells construct organic compounds from these inputs. The term identifies the combination of energy and carbon sources; it does not establish whether the culture can synthesise every other compound it requires.

Mineral nutrients and, where needed, organic growth factors must still be provided. A photoautotrophic culture also respires and can consume stored material during extended darkness. Its carbon balance therefore needs to combine accumulation and losses over the interval considered. Momentary carbon dioxide uptake in the light alone establishes neither permanent carbon storage nor a favourable overall energy balance.

Back to the term directory

Photobioreactor

Related search terms: PBR

A photobioreactor supplies light for biological processes, particularly cultivation of photosynthetic microalgae or cyanobacteria. Sunlight or artificial illumination forms part of the energy supply. The term describes a function rather than one particular geometry: flat-panel systems, tubular reactors and illuminated stirred tanks are different designs. Alongside nutrients, temperature and pH, illuminated area, optical path length and cell movement through the light field determine culture conditions.

Increasing biomass can cause growth-limiting self-shading, while high local light intensities may also be detrimental. Oxygen-producing photosynthesis requires coordinated CO₂ supply and oxygen removal. Stronger illumination cannot resolve a gas-transfer limitation. A closed vessel reduces certain contamination routes but does not demonstrate an axenic culture; inoculum quality, aseptic handling and appropriate purity testing remain essential.

Used in these chapters · 9
Back to the term directory

Photoinhibition

Related search terms: Light-induced inhibition

Photoinhibition is a reduction in photosynthetic capacity caused by excessive light exposure. Absorbed energy exceeds the capacity to process it productively or dissipate it safely. Damage to photosynthetic components and their repair form a dynamic balance. This differs from simple light saturation and from protective regulation that deliberately dissipates excess energy as heat.

Cells near an illuminated reactor surface can be strongly stressed while cells further inside remain light-limited. Mean illumination alone is therefore insufficient for assessment. Exposure duration and previous light history also influence the response. A temporary decrease in a photochemical indicator does not necessarily mean irreversible damage; recovery and longer-term culture performance are among the relevant biological considerations.

Used in these chapters · 1
Back to the term directory

Photon

A photon is a quantum of the electromagnetic field. For light in vacuum its energy is E = hν = hc/λ, with Planck constant h, frequency ν, speed of light c and wavelength λ.

Equal numbers of blue and red photons represent different energies because their wavelengths differ. A cultivation balance therefore cannot convert moles of photons to joules without spectral information. Biological use additionally depends on the culture state.

Foundations: Fundamental Physical Constants — Complete Listing

Used in these chapters · 7
Back to the term directory

Photon flux density

Related search terms: Photosynthetic photon flux density, PPFD

Photon flux density describes the quantity of photons reaching an area per unit time. For the photosynthetically active interval, PPFD is commonly expressed in µmol photons/(m² · s). It differs from a lamp’s total photon output because area, distance and orientation also matter. Identical units nevertheless do not guarantee an identical spatial definition.

Directional illumination of a plane and light arriving from every direction are different quantities. Absorption and scattering further alter the field inside a reactor, so a value at the outer wall does not describe every cell’s light environment. Useful reporting identifies location, geometry and wavelength interval. A single high peak is less informative for the whole culture than the relevant spatial and temporal distribution.

Used in these chapters · 4
Back to the term directory

Photoperiod

Related search terms: Day–night cycle

Photoperiod describes the duration of illumination within a regular day–night cycle. A schedule such as 16 hours of light and 8 hours of darkness specifies timing rather than total light input, which also depends on photon flux density and its variation through time. Photoperiod can influence growth, division and the use of stored compounds.

During extended darkness, photosynthetic cultures can continue respiring and consume reserves. Biomass gain observed in the light may therefore overestimate the balance across a complete day. Different schedules should be assessed on a comparable photon basis and across whole cycles. Longer illumination is not automatically preferable when biological rhythms, acclimation and energy expenditure are included.

Back to the term directory

Photosynthesis

Related search terms: Oxygenic photosynthesis

Photosynthesis converts light energy into chemically usable energy. In the oxygenic photosynthesis performed by plants, many algae and cyanobacteria, water supplies electrons and oxygen is released. Light reactions provide energy and reducing power that can support incorporation of inorganic carbon into organic compounds. The released oxygen therefore originates from water rather than from the carbon dioxide taken up.

Photobioprocesses require coordinated provision of light, carbon and other nutrients. More light alone does not guarantee faster growth. Cellular respiration also occurs, so measured gas exchange may combine opposing processes. Furthermore, calling carbon fixation a dark reaction does not mean that it occurs exclusively at night or independently of the light reactions.

Used in these chapters · 3
Back to the term directory

Photosynthetically active radiation (PAR)

Related search terms: PAR

Photosynthetically active radiation conventionally denotes wavelengths from 400 to 700 nanometres. The term first identifies a spectral interval; it is neither an intensity value nor a statement that every wavelength has identical biological effectiveness. Different pigment systems absorb and use this light differently. Biological responses can also occur outside the conventional interval.

A photobioprocess description must therefore also specify how many photons arrive and their spectral distribution. Two sources providing the same PAR photon supply can elicit different responses. A lamp’s electrical wattage does not answer this question because conversion losses, geometry and spectrum determine how electrical power becomes biologically usable light. The declared wavelength range should always accompany comparisons between lighting systems.

Back to the term directory

PID controller

Related search terms: PI controller

A PID controller forms its output request from three possible contributions: proportional action responds to the current control error, integral action to its accumulated history, and derivative action to its rate of change. Many bioprocess loops use PI control without derivative action where additional noise amplification is undesirable.

Parameters must match the dynamics and scaling of the actual loop. Higher gain does not automatically improve control; it may cause overshoot or instability. Limited pump and valve capacity requires appropriate handling of integral windup. When transferring settings between systems, different PID formulations and time units also matter: identically named parameters can have different mathematical meanings.

Used in these chapters · 1
Back to the term directory

Pigment

Related search terms: Pigments

A pigment is a colouring substance whose interaction with light preferentially affects particular spectral regions. Photosynthetic pigments absorb light and can contribute to energy capture or protection from excess excitation.

A culture’s pigment content can change without a proportional increase in dry mass. Colour or optical density is therefore not a universally direct biomass measurement. Pigment analysis documents extraction and measurement conditions and the specific pigment involved.

Foundations: Biology 2e: Light-dependent reactions of photosynthesis · Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 5
Back to the term directory

Pitched-blade impeller

Related search terms: Pitched-blade turbine

A pitched-blade impeller has flat blades inclined relative to the plane of rotation. This produces a substantial axial pumping component alongside radial motion. Blade angle, rotation direction and installation determine whether the main flow travels upwards or downwards and how circulation loops form within the vessel.

The design can provide useful bulk circulation and particle distribution, but it must suit the surrounding geometry. Equal blade counts do not imply equal power draw or pumping capacity. Changing blade pitch also changes several performance measures simultaneously. Describing an impeller as axial-flow does not mean all liquid travels parallel to the shaft: return paths and local cross-flow remain essential parts of the complete circulation pattern.

Back to the term directory

pKₐ value

Related search terms: pKa, apparent pKa

pKₐ is the negative base-ten logarithm of a consistently defined acid-dissociation constant. It describes that equilibrium, not the pH of every solution containing the acid. Standard state and temperature belong to its specification.

An apparent pKₐ may incorporate particular medium and activity effects and cannot automatically transfer to different salt conditions. In the simplified buffer relation, pH = pKₐ corresponds to equal activities of the conjugate forms.

Foundations: 14.6 Buffers

Back to the term directory

Plant cell culture

Related search terms: Plant suspension culture

Plant cell culture maintains cells of plant origin outside the intact plant. Cells may grow as aggregates in liquid medium and produce specialised metabolites or recombinant products. Plant origin does not necessarily imply dependence on light: many cultured lines receive an organic carbon source.

Cell walls, aggregate formation and developmental state shape cultivation behaviour. Large aggregates can experience different nutrient conditions internally and at their surface. Plant growth regulators and cultivation history also influence which characteristics are retained. High biomass production therefore does not automatically coincide with high production of the desired plant compound. Results obtained with leaves, roots and undifferentiated cell cultures cannot be transferred directly without considering these biological differences.

Back to the term directory

Plasmid copy number

Number of plasmid copies per cell or another explicitly specified reference. A population mean does not necessarily describe every individual cell.

More copies do not automatically produce more functional product. Interpretation requires the construct, host, measurement basis and culture state to be considered together.

Foundations: Addgene

Back to the term directory

Plasmid miniprep

Small-scale recovery of plasmid DNA from bacterial culture, separating target DNA from interfering culture and cellular constituents.

High DNA concentration alone does not establish suitable purity or correct construct identity. Assess compatibility with subsequent analysis and DNA identity separately.

Foundations: Addgene

Back to the term directory

Poisson distribution

The Poisson distribution describes non-negative integer counts with parameter λ; both its mean and variance are λ. It can arise from independent events occurring at a constant mean rate over the interval considered.

A plate count or rare event does not follow this model merely because it is integer-valued. Cell aggregates, changing rates and shared influences may produce greater variation. Dilution, sampled volume and the actual counting unit belong to the interpretation.

Foundations: Poisson distribution

Used in these chapters · 1
Back to the term directory

Polishing

Related search terms: final polishing

Polishing is a late purification duty targeting remaining unwanted components. Their identity depends on the preceding process and required final product. It names a task rather than one universal separation technology.

A suitable step sufficiently separates relevant impurities while preserving function and recovery. High overall purity does not replace measurement of particularly important individual components. Time, liquid burden and subsequent operations also matter in selection.

Foundations: Protein preparation handbook

Used in these chapters · 1
Back to the term directory

Pooling

Related search terms: pool, pooled fraction

Pooling combines defined fractions into a common liquid or product quantity. Combined concentration is total mass divided by total volume, not an unweighted average of concentrations. Keep fraction identity and origin traceable.

Quality measures need appropriate weighting or measurement of their own. Not every property is additive, and a favourable average does not automatically remove an individual requirement violation. Mathematically possible mixing is therefore not sufficient evidence for acceptable pooling.

Foundations: Biochemical Processing: Overview, lecture2

Used in these chapters · 11
Back to the term directory

Population doubling level

Related search terms: PDL, Net population doublings

Cumulative estimated net doublings of a documented cell population from a stated reference. For a bounded stage without unaccounted inputs or outputs, the increment is log₂(N_end/N_start). Passage number instead counts transfers under a convention.

The net ratio does not count every cell division or automatically correct cell loss. Branching, pooling and unknown prior history require additional ancestry records. A PDL without its origin cannot be reliably compared with a differently referenced value.

Foundations: ATCC Animal Cell Culture Guide · ICH Q5D: Derivation and Characterisation of Cell Substrates Used for Production of Biotechnological/Biological Products

Used in these chapters · 1
Back to the term directory

Power input per unit volume

Related search terms: P/V

Power input per unit volume, P/V, divides the mechanical power transferred to the liquid by the relevant liquid volume. Common units are W/m³ and W/L; 1 W/L equals 1000 W/m³. It describes an average power density and is frequently used when comparing agitation systems or transferring processes between scales.

It does not specify how energy is distributed throughout the vessel. Reactors with equal P/V can have different mixing times, local stresses and gas distributions. Comparisons must also state whether power is gassed or ungassed and identify the reference volume. When culture volume changes, constant impeller power does not maintain constant volumetric power input throughout the process.

Used in these chapters · 5
Back to the term directory

Power number

Related search terms: Newton number, NP

The power number expresses impeller power draw in dimensionless form: NP = P/(ρ · N³ · d⁵). P is power transferred to the liquid in W, ρ is density in kg/m³, N is rotational frequency in s⁻¹ and d is impeller diameter in m. It is also called the Newton number.

For fixed geometry, NP may be approximately constant in a sufficiently turbulent, ungassed regime. That assumption does not automatically hold after changes in flow regime, fill or aeration. A catalogue value must therefore be used with its reference conditions. The motor nameplate rating is also not directly the hydraulic power P: losses and the actual drive load must be distinguished.

Used in these chapters · 5
Back to the term directory

Power-law fluid

Related search terms: Ostwald–de Waele model

The power law τ = K·γ̇ⁿ describes shear stress as a function of shear rate. K is the consistency index in Pa·sⁿ and n is dimensionless.

An exponent below one gives shear thinning. The model does not necessarily represent limiting viscosities or time dependence and should not be extrapolated casually beyond measurements. K has units of Pa sⁿ when stress is expressed in Pa and shear rate in s⁻¹. Comparing K alone is misleading when exponents differ. For n below one, apparent viscosity diverges when extrapolated towards zero shear rate, illustrating why the supported measurement range must be stated.

Back to the term directory

Precipitation

Related search terms: precipitates

Precipitation forms a solid phase from previously dissolved constituents. Its occurrence and rate depend on species activities, temperature, solid phase and nucleation. Turbidity alone does not identify the precipitated material.

A medium comparison therefore separates total inventory, dissolved fraction and particles. The order of concentrated additions can alter local conditions despite an identical final ingredient list. Suitable analysis must investigate the proposed solid composition.

Foundations: 15.1 Precipitation and Dissolution

Used in these chapters · 7
Back to the term directory

Precision fermentation

A term for targeted production of selected molecules by cultured microorganisms, often using developed production strains. Food applications may focus on individual functional ingredients rather than the complete microbial biomass.

The label does not establish purity, safety, economics or environmental performance of a particular product. Recovery and purification need separate description. Product authorisation or absence of particular residual substances cannot be inferred from the process name alone.

Foundations: Our process

Used in these chapters · 3
Back to the term directory

Prediction interval

A prediction interval describes a range for a future observation under a specified model. It includes both uncertainty in the estimated mean relationship and variation of new observations.

It must therefore be distinguished from a confidence interval for a mean effect. A new reactor run can deviate substantially despite a precisely estimated mean. Prediction applies only to the modelled population, intended data region and assumed error conditions.

Foundations: How to confirm DOE results

Used in these chapters · 4
Back to the term directory

Pressure drop

Pressure drop describes the pressure requirement caused by resistance along a flow path or through a component. Pipe friction, bends, narrow passages and distributed resistances contribute. For a horizontal line with equal inlet and outlet cross-sections, a measured pressure difference can be assigned directly to these losses under appropriate conditions.

With elevation changes or different velocities, the pressure difference also contains other contributions and must not all be interpreted as friction loss. In a bioreactor system, pressure requirements influence which gas or liquid flows are actually achievable. A higher supply-pressure setting does not establish a suitable flow rate. Design must therefore reconcile the complete flow path, real fluid properties and allowable loads of its components.

Used in these chapters · 5
Back to the term directory

Pressure measurement

Pressure measurement detects mechanical loading by a gas or liquid, often through deformation of a sensing diaphragm. Every value needs an explicit reference: absolute pressure refers to vacuum, gauge pressure to ambient pressure, and differential pressure to two measurement locations. Numbers cannot be compared directly without this distinction.

In bioreactors, pressure measurement supports operating supervision, gas management and assessment of filter loading. A headspace reading does not equal every local pressure in the vessel because the liquid column contributes hydrostatic pressure. Condensate, blocked sensing lines and thermal effects can introduce errors. A pressure sensor also does not replace independently designed pressure protection; range, overload capability and hygienic connection must suit the application.

Used in these chapters · 1
Back to the term directory

Primary and secondary metabolites

Related search terms: Specialised metabolites

Primary metabolites are directly associated with basic cellular functions such as energy supply and construction of cell material. Secondary metabolites are often described as specialised metabolic products with roles in communication, competition or adaptation. Examples include certain microbial antibiotics and plant-derived compounds. The distinction is functional and is not equally clear for every molecule.

This classification does not impose a fixed production timetable. A secondary metabolite need not appear only after growth has completely stopped, and a primary metabolite is not automatically secreted in proportion to cell division. Production planning must establish the actual relationship between cellular state and product formation. Strong stimulation of growth can otherwise divert metabolism away from the desired specialised product.

Used in these chapters · 1
Back to the term directory

Process analytical technology

Related search terms: PAT

Process analytical technology, or PAT, connects timely measurements with process understanding and appropriate process management. It aims to understand and influence relevant material and process properties during manufacture. Sensors, sample analysis, mathematical models and statistical evaluation can contribute together; PAT does not simply denote a particular spectrometer.

In a bioreactor, combining nutrient measurements, cellular condition and a feeding strategy may stabilise product formation. This requires understanding how measured variables relate to the desired outcomes. More data alone do not improve quality, and correlation does not automatically establish a dependable causal relationship. Installing a PAT sensor also does not itself enable automatic product release; that needs a suitable overall strategy.

Used in these chapters · 3
Back to the term directory

Process historian

Related search terms: Historian

A process historian stores time-related process values and associated information for later retrieval and analysis. Ideally this includes time meaning, quality flags, units and event context.

Compression, filtering or change-only storage can affect the represented time series. A historical export is therefore not automatically an unchanged raw measurement. Balance calculations and model training document acquisition rules, outages and changes in the signal chain.

Foundations: OPC Unified Architecture

Used in these chapters · 4
Back to the term directory

Process recipe

Related search terms: process recipe

A process recipe describes the intended sequence and parameters of an operation. Depending on automation, it may include steps, setpoints, transition conditions and required inputs. It differs from the chemical formulation of a medium.

For bioreactors, preserve which recipe revision was actually used and which manual interventions occurred. A stored recipe does not automatically prove that the run followed it completely. Process records and recipe descriptions complement one another.

Back to the term directory

Process-material hold time

Related search terms: hold time, intermediate hold

A material hold time runs between explicitly defined states or processing steps. Assessment requires material, container, temperature, other conditions and relevant quality attributes. It is not automatically the same as total processing time or equipment occupancy.

Continuous collection can give individual portions different ages. A permitted duration transfers only within evidenced conditions. Scheduling can reveal violations of a stated limit but cannot itself demonstrate product stability.

Foundations: Biochemical Processing: Overview, lecture2 · Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 8
Back to the term directory

Product changeover

Related search terms: changeover, changeover time

Changeover comprises activities moving a resource from its previous state to one suitable for the next task. It may include cleaning, parts, preparation and state checks. Define scope for the actual transition.

Changing A to B need not equal changing B to A. Sequence-dependent durations must not be replaced casually with one average. Changeover already included in occupancy must not be added again as overhead.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 9
Back to the term directory

Product Environmental Footprint (PEF)

Related search terms: PEF, PEF method

PEF is the European Commission’s method for product life-cycle environmental assessment. It connects product function with specified modelling and evaluation requirements and extends beyond a single energy or climate measure.

A simplified operational comparison does not automatically meet all formal PEF requirements. Label method, data status and exclusions accordingly. Check relevant product-specific rules and applicable method versions for the actual use.

Foundations: Product Environmental Footprint method

Used in these chapters · 1
Back to the term directory

Product inhibition

Related search terms: Inhibitory product accumulation

Product inhibition is a reduction in biological conversion caused by a product that has formed. It can involve either the desired target compound or a by-product. A product may affect enzymes, stress membranes or shift a reaction equilibrium. Its effect often depends on other conditions; for organic acids, pH and the resulting distribution of chemical forms can be particularly relevant.

If a culture slows despite remaining nutrients, product inhibition is one possible explanation rather than an established diagnosis. Deliberately changing product concentration can help distinguish its contribution. Process assessment should also identify whether a concentration impairs growth, product formation or survival, because these responses need not occur at the same threshold.

Used in these chapters · 1
Back to the term directory

Product recovery

Related search terms: recovery

Product recovery describes the fraction of a defined input quantity obtained at a specified outlet. Input and output must measure the same analytically defined product form. Recovery differs from the purity of the resulting pool.

Across a sequence, fractions use each step’s incoming quantity and multiply when boundaries match. Absolute losses instead add. Initial and final inventories and later recovery must neither be omitted nor counted twice.

Foundations: Biochemical Processing: Overview, lecture2

Used in these chapters · 49
Back to the term directory

Product titre

Related search terms: Titre, Titer, Product titer

A concentration or assay-based quantity of product in the material considered. Dissolved compounds are often expressed in g/L, while biological particles may require other explicitly defined assay units.

Titre is not automatically total product, formation rate or functional quality. Total quantity additionally requires matching volume and concentration basis. Comparing titres requires compatible product definitions, methods and sample bases.

Used in these chapters · 24
Back to the term directory

Production campaign

Related search terms: campaign, batch campaign

A production campaign is a bounded sequence of batches and supporting activities with defined resources and states. It may repeat one product or include planned changes. Specify start, end and shared facilities.

Preparation, cleaning, storage and closing work do not disappear between batches. Their allocation determines duration and useful output. Compare campaign measures only with matching initial and final boundaries and material inventories.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 22
Back to the term directory

Production strain

Related search terms: Microbial production strain

A production strain is a specifically identified microbial lineage selected or developed for a manufacturing process. Its properties extend well beyond the species name: substrate utilisation, by-product formation, productivity and genetic stability can vary substantially between strains of the same species. The strain designation is therefore an essential part of a reproducible process description.

Selection should reflect performance under the intended operating conditions. A strain producing large amounts in a small screening experiment may lose performance during longer cultivation or under different nutrient conditions. Genetic modifications can also impose a growth burden. The appropriate choice combines biological robustness, product quality and process compatibility rather than relying on a single maximum yield value.

Used in these chapters · 2
Back to the term directory

Profitability index

Related search terms: profitability index

For an initial investment followed by positive net cash inflows, the profitability index is their present value divided by the initial outlay. More complex payment series require an explicitly stated convention.

A larger ratio can coincide with a smaller absolute net present value. The index therefore cannot alone rank mutually exclusive equipment alternatives. Technical suitability and available funds also belong in the decision.

Foundations: 11.4 Discounted Cash Flow Models

Back to the term directory

Programmable logic controller

Related search terms: PLC

A programmable logic controller, or PLC, processes input and output signals according to stored software. It can acquire measurements, switch valves, operate pumps and execute control algorithms. These tasks follow a defined execution and timing structure that must suit the dynamics of the connected equipment.

For bioreactors, a PLC supports repeatable sequences and specified responses to operating conditions. The device label alone does not demonstrate functional safety, data integrity or software suitability. Architecture, programming, verified functions and intended fault responses are decisive. An ordinary PLC is not automatically a safety controller. During network or operator-computer failure, its implemented local continuation or shutdown behaviour must be understood.

Used in these chapters · 1
Back to the term directory

Promoter

DNA region involved in initiating transcription. Its activity depends on a compatible cellular transcription system and other regulatory conditions.

A promoter described as strong does not guarantee productivity. Transcription, protein synthesis, folding and product degradation are distinct stages in the manufacturing chain.

Foundations: Addgene

Back to the term directory

Protein

Related search terms: Proteins

A biomolecule comprising one or more amino-acid chains. Sequence, three-dimensional structure and possible modifications contribute to its properties. Proteins can perform catalytic, structural, transport or regulatory functions.

Total protein measurement does not automatically determine the quantity or activity of a particular target protein. Equal mass can contain different functional fractions. Manufacturing and downstream processing therefore distinguish identity, concentration, structure and function as product attributes.

Foundations: Protein

Used in these chapters · 26
Back to the term directory

Protein A

Related search terms: Protein-A

Protein A is a bacterial protein whose suitable antibody-binding properties are used in affinity purification. Technical resins may use natural or recombinant ligands or modified binding domains.

Antibody forms do not bind identically under every condition. A Protein A step is therefore not universal capture for all bioproducts. Ligand, product, feed conditions, recovery and possible ligand-related impurities belong in the specific process assessment.

Foundations: CaptivA HF Protein A Affinity Resin

Used in these chapters · 1
Back to the term directory

Pseudogene

A pseudogene is a DNA region resembling a gene whose original protein-producing function has typically been lost through sequence changes. The label does not automatically mean that the region has no regulatory or other biological relevance.

Sequence similarity matters when characterising a cell line: an insufficiently specific assay can also detect related regions. A positive signal would then fail to identify the intended production sequence uniquely. The method must distinguish the sequences relevant to the question; a nonspecific combined signal is insufficient for that purpose.

Foundations: NHGRI: Pseudogene

Back to the term directory

Pump curve

Related search terms: pump curve

A pump curve plots a pump property against volumetric flow, for example head or efficiency. Speed, impeller geometry and test liquid belong to the valid description.

Actual flow results from interaction with the connected system. A large nominal flow does not guarantee that a long bioreactor loop achieves it. Changes in speed or fluid properties require a correspondingly justified curve.

Foundations: Improving Pumping System Performance: A Sourcebook for Industry

Back to the term directory

Pump head

Related search terms: pump head

Pump head expresses mechanical energy transferred per unit weight as a length. For an incompressible liquid, a pure pressure increase Δp corresponds to H = Δp/(ρg).

Elevation and velocity contributions additionally belong in a complete balance across the chosen boundary. Metres of head therefore do not simply mean metres of pipe. The same head corresponds to different pressure differences at different liquid densities.

Foundations: Improving Pumping System Performance: A Sourcebook for Industry

Used in these chapters · 2
Back to the term directory

Pumping number

Related search terms: Flow number, NQ

The pumping number expresses an impeller's flow capacity in dimensionless form. A common definition is NQ = Q/(N · d³), using pumping flow Q in m³/s, rotational frequency N in s⁻¹ and impeller diameter d in m. The surface and method used to determine Q must be specified.

The number helps compare the ability to move liquid on a large scale. It is distinct from the power number: an impeller can pump substantial liquid without producing the same local break-up action as another design. Primary impeller discharge is also not necessarily the total vessel circulation. Installation geometry, aeration and other impeller stages can substantially change the circulation that is useful to the process.

Used in these chapters · 1
Back to the term directory

PUPSIT

Related search terms: pre-use post-sterilisation integrity testing

PUPSIT means testing the integrity of a sterilised filter assembly before it is used. It is intended to reveal damage arising during preparation or sterilisation. Sequence matters: a test performed before sterilisation cannot detect damage caused by that later step. The test arrangement must itself preserve the sterile barrier already established.

In the EU GMP context for sterile medicinal products for human use, Annex 1 addresses PUPSIT for the relevant sterilising filtration and sets conditions for justified alternatives where process constraints prevent its performance. This is not a blanket requirement for every research bioreactor or every gas filter. A risk assessment without effective controls does not provide the required assurance. Post-use integrity testing and product-specific filter suitability remain separate considerations.

Back to the term directory

Pure error

Pure error is the variation of replicated observations at identical modelled conditions around their group means in a regression decomposition. It estimates repeat variation separately from the chosen response-surface form.

Replicates must match the experimental level claimed. If days or other block influences differ, grouping must be defined accordingly. Small pure error from analytical duplicates does not automatically describe variation between independent reactor runs.

Foundations: Testing missing or misspecified model terms

Back to the term directory

Pure steam

Related search terms: clean steam

Pure steam is generated for a defined application with demanding cleanliness requirements. Unlike steam used only for heating, it may contact product-contact surfaces during direct sterilisation. Feedwater, generation and distribution are therefore assessed to prevent transfer of relevant amounts of unwanted substances. Condensate is often used to evaluate selected chemical properties.

The term itself does not establish one globally uniform specification for every installation. Pharmaceutical applications require attention to the applicable expectations for directly used steam and its condensate. Non-condensable gases, moisture content and superheating remain separate quality characteristics. A correctly specified generator also does not guarantee identical quality at every point of use without suitable distribution, operation and verification throughout the system.

Used in these chapters · 3
Back to the term directory

Purity

Related search terms: product purity

Purity describes the target product fraction or analytically determined composition relative to an explicitly defined basis. Mass fraction, analytical peak-area fraction and biological activity are different quantities.

High recovery does not automatically imply high purity. Purification therefore tracks product quantity, relevant impurities and suitable measurement methods separately. A purity value without its method and basis is insufficient for comparison.

Foundations: Biochemical Processing: Overview, lecture2 · Protein preparation handbook

Used in these chapters · 25
Back to the term directory

Q

Qualification

Related search terms: equipment qualification

Qualification provides documented evidence that facilities, systems or equipment are suitable for their defined use. It connects requirements with assessment of design, installation, operation and, where relevant, application-specific performance. Individual stages can be combined sensibly when their objectives and evidence remain clear. Demonstrated suitability matters more than the number of separate document folders.

Qualification establishes conditions for a controlled process but does not replace every product-specific validation. Correct temperature control, for example, does not prove adequate treatment of every location in a particular load. Modifications, wear and unassessed replacement parts can also alter the qualified state. Appropriate change assessment and maintenance therefore support continued use of the evidence. Scope follows critical functions and actual intended use.

Used in these chapters · 17
Back to the term directory

Quantification limit

Related search terms: LOQ, limit of quantification

The quantification limit is the lowest amount or concentration that a defined analytical procedure can determine with sufficiently suitable accuracy and precision. It typically exceeds the detection limit because a recognisable signal does not yet support a dependable numerical result. Required performance depends on the intended use.

A substrate may, for example, be detectable in a bioprocess while its low concentration cannot be measured reliably enough for fine feed control. Sample dilution changes the limit expressed relative to the original medium and must be accounted for. Extra decimal places create no additional analytical information. The limit should apply to the actual matrix and preparation and be confirmed with suitable low-concentration samples.

Used in these chapters · 3
Back to the term directory

Quantile

Related search terms: percentile

A quantile identifies a value at a specified position in an ordered distribution. A 0.5 quantile is a median, while percentiles express the position as a percentage. For finite samples, different accepted interpolation conventions may produce different values, especially with small datasets.

A reported result therefore states probability level, weighting and calculation method. The 90th percentile of a number-weighted pellet distribution differs from an area-weighted percentile. Quantiles describe parts of a distribution but do not establish representative sampling. They also differ from a confidence interval for an estimated parameter; the two describe different kinds of statistical information.

Foundations: Percentiles

Back to the term directory

Quantisation

Related search terms: Quantization, Quantisation error

Quantisation maps a continuous or finely resolved signal onto discrete numerical levels. Under ideal rounding to equally spaced levels separated by Δ, rounding error lies between −Δ/2 and +Δ/2.

If this error is justifiably modelled as uniform, its standard deviation is Δ/√12. This is not a general accuracy statement: calibration, noise, saturation and signal processing add further contributions. Displaying more decimal places does not restore lost information.

Foundations: Uniform distribution · Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 1
Back to the term directory

Quantum yield

Related search terms: Photosynthetic quantum yield

Quantum yield relates the number of a defined light-driven event to the number of photons absorbed. In photosynthesis, one example is carbon dioxide fixed per quantity of absorbed photons, expressed as mol CO₂/mol photons. The definition must identify whether it concerns gross fixation or a net value after opposing losses.

Using incident rather than absorbed photons produces a different, apparent quantity that also includes optical effects. Photochemical efficiency of a photosystem and biomass formation per photon are likewise not interchangeable. High quantum yield under weak illumination therefore does not guarantee high daily production. Engineering comparisons should state the radiation basis, the biological event considered and the absolute conversion achieved.

Back to the term directory

R

Radiation sterilisation

Related search terms: irradiation

Ionising radiation can inactivate microorganisms by directly and indirectly damaging their cellular components. Gamma radiation, electron beams and X-rays are used for certain disposable components. Absorbed dose describes energy received per unit mass; one gray equals one joule per kilogram. The dose distribution within the actual packaging and load matters, rather than a nominal equipment setting alone.

The minimum dose must be microbiologically justified, while the maximum dose must remain compatible with the materials. Polymers may become brittle, discolour or release different extractable substances. Assessment therefore includes ageing and subsequent processing steps. Successful irradiation does not make damaged packaging acceptable and demonstrates neither freedom from endotoxins nor an unlimited storage life for the treated assembly.

Back to the term directory

Radiative transfer

Radiative transfer describes spatial, spectral and directional radiation propagation while accounting for sources and interactions. Absorption and scattering are especially relevant in a suspension.

A full model requires more information than one average light value, including boundary illumination and optical properties. For a photobioreactor, the model is chosen for the intended question and checked against appropriate measurements; mathematical complexity does not replace that assessment.

Foundations: Temporal scaling of the growth dependent radiative properties of microalgae

Back to the term directory

Raman spectroscopy

Raman spectroscopy examines weak inelastic scattering of light, usually from a laser. Energy shifts in the scattered light relate to molecular vibrations and produce a chemically informative spectrum. With suitable models, spectra of culture media can support estimation of nutrients and metabolic products.

A probe may allow direct reactor measurements, but a spectrum does not automatically yield dependable concentrations. Fluorescence background, turbidity, temperature and changing medium lots can affect the model. Quantitative models require appropriate reference analyses and independent evaluation. An apparently strong prediction based merely on coincidental time trends is particularly problematic. New cell lines or altered feeding strategies may then lie outside the model’s dependable operating domain.

Back to the term directory

Randomisation

Related search terms: Random assignment

Randomisation uses a documented random mechanism to assign conditions or order within a permissible design. It avoids systematically coupling treatment allocation with unknown nuisance influences through deliberate or inadvertent assignment choices.

A particular realised design can still be imbalanced by chance. Known strong influences are additionally addressed through blocking or suitable restricted designs. Randomisation replaces neither independent experimental units nor scientifically permissible settings.

Foundations: Randomized block designs · Two-level full factorial designs

Used in these chapters · 6
Back to the term directory

Real and nominal values

Related search terms: real price basis, nominal revenue

Nominal monetary values use prices of the relevant period. Real values refer to a specified price basis and account for changes in price levels. State the method and reference period.

Rising nominal equipment revenue may reflect more sales, higher prices or both. Bioreactor cost models need consistent pairing of real payment assumptions with real discounting; avoid adding nominal escalation silently or inconsistently.

Used in these chapters · 1
Back to the term directory

Recovery Point Objective (RPO)

Related search terms: RPO

The Recovery Point Objective identifies the data point to which records should be restored after a disruption. It therefore expresses the timing boundary of potentially tolerable data loss, rather than the duration of repair or recovery.

In a bioprocess, a short gap around a critical event can matter more than a longer gap in an unimportant trend. Backup and local buffering need to fit the purpose of the record. Support the objective with an actually tested restoration route, not merely the existence of a backup file.

Foundations: Recovery Point Objective

Used in these chapters · 1
Back to the term directory

Recovery Time Objective (RTO)

Related search terms: RTO

The Recovery Time Objective specifies the target period within which an unavailable function needs restoration to avoid unacceptable impact on the intended operation. It is a planning objective, not an automatically demonstrated service performance.

For a bioreactor, the target must fit the actual process sensitivity. A rapid first service response differs from restored supply. Assess the planned recovery route including diagnosis, replacement, verification and return to operation.

Foundations: Recovery Time Objective

Used in these chapters · 1
Back to the term directory

Rectangular distribution

Related search terms: Continuous uniform distribution

A continuous rectangular distribution has constant probability density within a specified interval and zero density outside. For the symmetric interval from −a to +a, standard deviation is a/√3.

In uncertainty evaluation it is one possible model for bounded values without justified preference within the interval. A manufacturer’s limit does not automatically mandate this model. Interval width and rationale are recorded separately from empirically measured variation.

Foundations: Uniform distribution · Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Back to the term directory

Redox potential

Related search terms: ORP, oxidation–reduction potential

Redox potential describes the tendency of a medium to accept or donate electrons as observed at a measuring electrode. Process instruments often use a noble-metal electrode and a reference electrode, reporting millivolts. Complex culture media usually produce a mixed potential involving several active redox systems rather than a selective signal for one compound.

The trend can indicate changing oxygen availability or reducing metabolic conditions. It cannot generally be converted into a particular oxygen concentration. pH, temperature, reference system and electrode deposits affect the reading. Comparable values therefore require the same reference scale and suitable conditions. A strongly negative signal alone proves neither complete oxygen absence nor a specific microbial pathway.

Used in these chapters · 1
Back to the term directory

Reference material

Related search terms: Reference standard

Material sufficiently suitable, homogeneous and stable in specified properties for an intended measurement use, such as method assessment or quality control. Relevant properties must match that use.

A reference material is not automatically a certified reference material with documented assigned values, uncertainties and traceability. Known origin alone also does not guarantee suitability for comparison with complex culture samples. State material basis, property and intended scope.

Foundations: International vocabulary of metrology

Used in these chapters · 6
Back to the term directory

Replenishment lead time

Related search terms: supply lead time, replenishment lead time

Replenishment lead time is the interval between a defined ordering event and usable availability of the required item. Depending on its definition, it can include manufacture, transport, receipt and internal checks. State the start and end points explicitly.

For bioreactor assemblies, arrival of a box is less important than timely availability of a suitable configuration. Demand during replenishment and a justified reserve influence the reorder trigger. Do not hide variable delivery times behind an unlabelled average.

Used in these chapters · 1
Back to the term directory

Representative sample

A representative sample adequately reflects the culture properties relevant to a question at a defined sampling time. Every microscopic detail need not be identical, but the concentration or distribution of interest should not be systematically distorted by withdrawal. Mixing, sampling location and sample volume strongly influence which components enter the sample.

Settling cells, aggregates or proximity to an addition point can shift composition. Information may also be lost after withdrawal if metabolism continues or gas escapes. Representativeness therefore belongs to the entire sampling and handling chain. Repeatedly analysing the same unsuitable sample may reduce analytical scatter, but it cannot remove the original systematic sampling bias.

Used in these chapters · 4
Back to the term directory

Requirements traceability

Related search terms: traceability matrix

Requirements traceability connects a stated requirement with its implementation, verification and decision. A matrix is one possible presentation. It can identify the function satisfying a requirement and the report containing its evidence.

For bioreactors, this association helps prevent a demonstrated feature from being mistaken for part of the ordered configuration. After a change, affected requirements can be identified selectively. A completed matrix nevertheless replaces neither the experiment nor scientific assessment of its result.

Used in these chapters · 1
Back to the term directory

Residence-time distribution

Related search terms: RTD

A residence-time distribution describes how long different fluid elements remain within a defined flow region before leaving it. It can be determined, for example, from the response to a short tracer input. A narrow distribution indicates similar transit times; a broad distribution indicates that different portions of liquid spend different times in the system.

It helps investigate short-circuiting, back-mixing and slowly exchanging regions that a mean residence time alone cannot describe. System boundaries matter: a complete reactor and one circulation loop have different distributions. For scale-down, time spent in a challenging region may matter more than total residence. A liquid tracer distribution also does not automatically represent the age distribution of growing or intentionally retained cells.

Used in these chapters · 8
Back to the term directory

Residual sum of squares

Related search terms: SSE, Error sum of squares

Residual sum of squares, SSE, is the sum of squared differences between observations and fitted model values. It is the ordinary least-squares optimisation criterion and has the squared unit of the response.

SSE depends on observation count and selection as well as model complexity. Additional terms can reduce it on the same fitting data without improving prediction. Variance estimation and model comparison therefore consider degrees of freedom, residual structure and independent confirmation.

Foundations: Testing missing or misspecified model terms

Used in these chapters · 3
Back to the term directory

Respiratory quotient

Related search terms: RQ

Respiratory quotient, RQ, is the molar ratio of carbon dioxide production to oxygen consumption: RQ = CER/OUR. It is dimensionless when both rates use the same time and volume basis. Changes can indicate altered metabolism because different conversion pathways relate the two gases in different proportions.

Reliable interpretation requires matching system boundaries, time intervals and balance conventions for CER and OUR. CO₂ accumulation, external CO₂ supply or very low oxygen uptake can strongly affect the ratio. A particular RQ therefore does not uniquely identify a substrate or metabolic pathway. As OUR approaches zero, small errors become strongly amplified and the quotient may become diagnostically unusable even when the individual measurements appear plausible.

Used in these chapters · 4
Back to the term directory

Response surface

Related search terms: Response-surface model

A response surface describes a response as a function of several factors. Local process development often uses a quadratic regression model containing linear, interaction and squared terms.

The model can reveal curvature and competing objectives within a studied region. A numerical maximum remains conditional on the region, model and quality constraints. Scientific confirmation requires additional suitable runs and independently assessed responses.

Foundations: Response surface model example

Used in these chapters · 4
Back to the term directory

Response time

Response time describes how quickly a measuring system responds to a change in its measurand. A specification such as t₉₀ denotes the time required to reach 90% of the final signal change after a defined step. Numbers are only partly comparable without the step direction, medium, temperature and test conditions.

In operation, the sensing element is only one contributor. Membranes, thermowells, liquid movement and electronic filters can slow the complete measurement chain. Rapid data transmission therefore does not necessarily provide rapid process measurement. For control and sample comparisons, the sensor must resolve the relevant biological dynamics. Heavy smoothing makes traces calmer but can attenuate or delay brief oxygen or pH excursions.

Used in these chapters · 13
Back to the term directory

Response variable

Related search terms: Response

A response variable is the experimental outcome evaluated by a defined method, for example product mass formed over a specified interval. Its definition includes the measured quantity, aggregation and time basis.

Biomass concentration, total mass and recovered target product answer different questions. When several responses are assessed together, mandatory quality constraints must be separated from weighted optimisation objectives. A larger primary response does not automatically compensate for unacceptable quality.

Foundations: Multiple response case

Used in these chapters · 35
Back to the term directory

Restriction digest

Cleavage of DNA using enzymes that recognise particular sequences. Results depend on DNA sequence, enzyme and suitable reaction conditions.

The fragment pattern can support construct verification. It does not replace sequence confirmation of every region critical to the intended use.

Foundations: Addgene

Back to the term directory

Restriction map

Representation of selected recognition or cleavage positions in a DNA construct, allowing expected fragment sizes to be predicted.

A map predicts from a specified sequence version. Compare observed fragments against that version; an outdated map can obscure a construct change.

Foundations: Addgene

Back to the term directory

Restriction site

DNA sequence recognised by a particular restriction enzyme; actual cleavage position is enzyme-dependent. A map must therefore identify the enzyme used.

An altered site can change a diagnostic pattern. Conversely, changes outside the examined sites may remain hidden within an unchanged pattern.

Foundations: Addgene

Back to the term directory

Retentate

Related search terms: retentate stream

Retentate is the liquid stream or inventory remaining on the feed side of a membrane. In recirculating filtration it may return to the feed vessel or bioreactor. It is not automatically purified product.

Its composition changes through concentration, solute passage and additions. A balance distinguishes internal return from retentate actually removed from the system. Only the latter is an external outlet across the selected boundary.

Foundations: KrosFlo KR2i Tangential Flow Filtration System · Protein preparation handbook

Used in these chapters · 4
Back to the term directory

Retrofitting

Related search terms: retrofit, retrofitting

Retrofitting modernises existing equipment through new components or functions while retaining part of the former system. Suitability therefore concerns the combination of retained and new technology.

A bioreactor controller may be replaced while the vessel and agitator remain in use. Mechanical suitability, connections, control, data and responsibilities must fit together. A new controller does not resolve unidentified vessel damage, while age alone does not make a sound vessel unsuitable.

Foundations: xCUBIO benchtop configuration

Used in these chapters · 11
Back to the term directory

Reynolds number

Related search terms: Re

The Reynolds number compares inertial and viscous effects in a flow. For a stirred vessel, a common definition is Re = ρ · N · d²/μ, using density ρ, rotational frequency N in s⁻¹, impeller diameter d and dynamic viscosity μ in consistent SI units. The result is dimensionless.

It helps classify flow behaviour and assess the applicability of impeller correlations. Its meaning depends on the definition: pipe-flow Reynolds numbers use different characteristic quantities. Transition thresholds quoted for pipes should therefore not simply be transferred to every stirred tank. Non-Newtonian liquids also require adapted definitions; inserting an arbitrarily chosen apparent viscosity can produce a misleading description of the reactor flow.

Used in these chapters · 8
Back to the term directory

Riser and downcomer

Related search terms: riser, downcomer

Riser and downcomer denote regions of predominantly upward and downward liquid movement in a circulation system. In airlift reactors, different gas holdups commonly support circulation.

The terms describe flow functions, not necessarily separate pipes. Gas entrainment in the downcomer, turns and flow resistance affect actual circulation. The names refer to predominant liquid movement within the circulation being considered. Depending on geometry and conditions, gas may also enter the downcomer. The label alone therefore establishes neither a gas-free zone nor specific residence durations; flow, volumes and exchange are needed for those conclusions.

Used in these chapters · 1
Back to the term directory

Risk assessment

Related search terms: quality risk assessment

A risk assessment identifies potential hazards and analyses and evaluates the associated risks to a defined objective. In bioprocess quality, an example is unwanted microbial entry through a connection. Likelihood and severity are considered; detectability may be included depending on the method used. Available evidence and uncertainty should remain visible.

A calculated risk score is not an objective physical constant. Coarse rankings and unsupported assumptions can create a misleading impression of precision. Scientific justification and effective controls, such as improved design or a controlled operating step, matter more than the number alone. Assessment is reviewed after relevant changes. Quality, occupational safety and environmental risks can interact, but they have different protection objectives and should not be merged without distinction.

Used in these chapters · 3
Back to the term directory

RNA – ribonucleic acid

Related search terms: RNA, Ribonucleic acid

A nucleic acid with a ribose-phosphate backbone and adenine, cytosine, guanine and uracil bases. RNA is often single-stranded and can transfer information, form structures, support regulation or have catalytic functions.

Not every RNA is a messenger for a protein. Measured RNA content is also not automatically the quantity of functional final product. Process analysis should identify the RNA type, measurement basis and relationship to the desired function.

Foundations: Ribonucleic acid

Back to the term directory

Rocking bioreactor

Related search terms: Wave-mixed bioreactor

A rocking bioreactor moves its culture liquid by periodically tilting a vessel, commonly a flexible bag. The resulting wave circulates the liquid and renews its free surface, supporting exchange with gas in the headspace. Some systems provide additional gas delivery, so rocking does not necessarily imply surface aeration alone.

Rocking angle, frequency, vessel shape and fill volume jointly determine the flow. Increasing the liquid fill changes both wave behaviour and the ratio of exposed surface area to liquid volume. Matching rocking frequency alone therefore does not reproduce conditions between systems. Absence of an impeller also does not eliminate mechanical stress: wave breaking, entrained bubbles and local velocity gradients remain relevant to sensitive cultures.

Back to the term directory

Role-based access control (RBAC)

Related search terms: RBAC

Role-based access control assigns permissions to defined task roles. Users obtain rights through roles such as operation, technical support or data review. This allocation differs from verifying user identity.

A bioreactor operator role may permit starting a run without allowing programme or permission changes. Sharing a role does not require sharing an account. Individual attribution of actions and appropriately limited permissions remain separate requirements.

Foundations: Role Based Access Control

Back to the term directory

Root mean squared error

Related search terms: RMSE

RMSE is the square root of the mean squared difference between predictions and reference values. It has the response’s unit and gives greater emphasis to large deviations than mean absolute error.

A small overall value can hide poor predictions in short but decisive process phases. Comparable assessments use the same test population and weighting. RMSE calculated with denominator n differs from residual standard deviation using a degrees-of-freedom-adjusted denominator.

Foundations: Metrics and scoring: quantifying prediction quality

Used in these chapters · 1
Back to the term directory

Rotatability

Rotatability means that, for an appropriate response-surface model, variance of the predicted mean depends only on distance from the design centre and not on direction. This property refers to the chosen coded coordinates.

It does not guarantee equal biological effects or identical precision everywhere in the design region. A rotatable design may require scientifically impermissible settings. The geometric property must therefore be assessed alongside process limits and the actual model assumptions.

Foundations: Central Composite Designs

Used in these chapters · 1
Back to the term directory

Rushton turbine

Related search terms: Disc turbine

A Rushton turbine is a radial-flow impeller with vertical flat blades mounted on a horizontal disc, conventionally with six blades. Its main discharge travels towards the vessel wall, where it feeds returning circulation loops. Strong local flow structures develop behind the blades and can break up gas bubbles under suitable conditions.

This makes the design relevant to gas dispersion, but the resulting mechanical environment is spatially uneven. Aeration changes power draw and can reduce effective pumping when gas loading becomes excessive. A Rushton turbine is therefore neither categorically unsuitable for cell culture nor automatically the best choice for microbial processes. Process demand, gas loading and the installed hydraulic arrangement determine its usefulness.

Used in these chapters · 1
Back to the term directory

S

Saddle point

Here a saddle point denotes a stationary point of a smooth function that is neither a local maximum nor a local minimum. Nearby function values occur both above and below the value at that point.

An indefinite Hessian at a stationary point indicates different curvature directions under suitable differentiability assumptions. Solving gradient = 0 alone therefore does not select a process condition. Curvature, boundaries and quality requirements must also be assessed.

Used in these chapters · 1
Back to the term directory

Safety stock

Related search terms: safety stock

Safety stock is additional inventory intended to absorb uncertainty in demand or replenishment. Its appropriate size depends on variability, tolerated shortages and shelf life, among other factors. An arbitrarily chosen reserve is not a statistically justified safety stock.

Bioreactor consumable reserves must match the actual configuration and remain usable. More stock can reduce supply consequences but also increase expiry waste and tied-up funds. Document assumptions together with the ordering procedure.

Used in these chapters · 1
Back to the term directory

Sampling aliasing

Related search terms: Aliasing

Aliasing is ambiguity between frequency components caused by inadequate sampling. A rapid periodic variation may consequently appear slower or disappear.

For an ideally band-limited signal, sampling above twice its highest frequency is a theoretical requirement for unique reconstruction. Actual measurement chains additionally need appropriate filtering and task-specific margin. For example, samples of sin(2π · 0.8t) taken uniformly at 1 Hz equal those of −sin(2π · 0.2t). The recorded values alone cannot distinguish the two signals. Retrospective smoothing cannot uniquely reconstruct the unknown original rapid trajectory from that already aliased dataset.

Used in these chapters · 1
Back to the term directory

Sampling dead volume

Sampling dead volume is the liquid space between a representatively exchanged process region and the collection vessel whose contents initially travel with the sample. Older broth or flushing liquid may remain there. Unless this contribution is addressed, the first withdrawn liquid may not represent the current reactor contents.

Actual tubing layout, valve cavities and exchange behaviour matter, not merely nominal tubing length. A suitable flushing or discard volume therefore cannot be prescribed as a universal multiplier; it must suit the arrangement and analytical purpose. Very small samples can be disproportionately affected by residual volumes. Dead volume, sample loss and withdrawal delay should be reduced together without compromising the sterile barrier or effective flushing.

Used in these chapters · 1
Back to the term directory

Sampling frequency

Sampling frequency describes how often a new sample or observation is obtained. It must match the speed of the process change being investigated. A daily cell count may capture a slow trend, whereas a brief substrate excess after feeding could remain entirely undetected between such measurements.

More frequent withdrawal improves temporal resolution but consumes additional sample and may increase process intervention. Transport, analysis time and sensor response also limit when genuinely new information becomes available. An instrument’s logging rate is therefore not necessarily the rate of independent measurements. Experimental planning should consider relevant events, required sample volume and analytical capacity together. Event-triggered sampling can usefully supplement a fixed schedule.

Used in these chapters · 1
Back to the term directory

SCADA

SCADA means supervisory control and data acquisition: an upper-level system for process supervision, operation and data collection. It can combine measurements from several devices, display trends, manage alarms and send setpoints to underlying controllers. The actual allocation of functions depends on the equipment architecture.

In a bioreactor system, a local controller may continue time-critical control while SCADA provides the interface and long-term records. A live trend display does not prove complete data backup or uninterrupted control during communication loss. Assessment requires understanding timestamps, buffering, restart behaviour and responsibilities. A data-export function alone likewise does not make all records complete, traceable and protected against unnoticed alteration.

Back to the term directory

Scalar photon fluence rate

Related search terms: PPFFR, Scalar photon flux density

Scalar photon fluence rate sums directional radiation contributions over all directions without cosine projection onto one fixed plane. For photosynthetically active photons it is commonly expressed in µmol m⁻² s⁻¹.

Spherical and planar PPFD measurement geometries therefore measure different quantities. In a scattering culture, the scalar quantity may help describe local exposure. It cannot be used as net input through a reactor wall without a geometrically justified conversion.

Foundations: Measuring PPFD and PPFFR with underwater sensors · Temporal scaling of the growth dependent radiative properties of microalgae

Used in these chapters · 1
Back to the term directory

Scale-down

Scale-down reproduces selected, important features of a larger process in a smaller experimental system. A small reactor may deliberately create uneven or changing conditions when these are characteristic of the target plant. The objective is an informative model of relevant exposure, rather than necessarily the best possible laboratory supply conditions.

The research question and the relationship to the larger scale must be clear. For concentration fluctuations, exposure magnitude, duration and recurrence may need to be represented. A geometrically small replica without the appropriate cell environment is not automatically a useful scale-down model. Conversely, reproducing one challenge successfully does not demonstrate that all risks and product attributes of the large process have been covered.

Used in these chapters · 12
Back to the term directory

Scale-up

Scale-up transfers a process to a larger engineering scale while preserving the biological and product-related outcomes that matter. It is not achieved by enlarging all dimensions and settings proportionally. Geometry, flow, gas supply and heat removal change according to different relationships and can introduce new limitations.

A useful approach starts with culture requirements and the capabilities of the target reactor. Oxygen delivery, mixing time or particle motion may deserve priority, depending on the process. Equal rotational speed or equal P/V alone therefore does not demonstrate successful transfer. Engineering criteria must be linked to actual process outcomes. Successful growth without assessing the relevant product attributes likewise provides incomplete evidence of equivalent performance at the larger scale.

Used in these chapters · 23
Back to the term directory

Scenario analysis

Related search terms: scenario analysis

Scenario analysis compares coherent combinations of assumptions. One scenario may combine a particular utilisation level with matching staffing and utility costs. It is neither measured data nor automatically a probability distribution.

For bioreactors, the method can compare a small development programme with later expansion. Each set of assumptions must remain technically consistent. High product sales without the necessary capacity would not form a coherent scenario.

Back to the term directory

Schedule makespan

Related search terms: makespan, campaign duration

Makespan is the span from the specified first start to the final completion of the selected tasks. It describes a finite schedule, not the sum of all durations when work overlaps.

It is also not summed material waiting. Two options may have equal long-run throughput yet different final completion times. State included starting and ending states so preparation or closing work does not disappear.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 3
Back to the term directory

Seal

Related search terms: gasket, sealing element

A seal limits material exchange between separate regions and maintains an intended barrier at a joint or penetration. Its effectiveness depends on geometry, material and adequate compression. In sterile bioprocessing, pressure and temperature resistance must be considered together with cleaning, sterilisation and contact with the process fluid. Repeated cycles can alter its properties.

The name of a generally suitable elastomer does not guarantee suitability of every compound or installation. Swelling, compression set, cracks and protruding edges can create leakage or poorly cleanable crevices. A connection that appears tight may behave differently during cooling or changing loads. Selection and replacement intervals should therefore reflect actual exposure. Excessive tightening is not a reliable substitute for the correct seal and compatible joint geometry.

Used in these chapters · 8
Back to the term directory

Seed train

Related search terms: Inoculum expansion, Seed expansion

A seed train is the planned sequence of cultivation stages that expands a small starting culture into enough suitable inoculum for production. Its purpose is to increase cell quantity while retaining a defined physiological state. Changing vessels is therefore a biological transition, potentially involving adaptation to different nutrient supply, surfaces and mixing conditions.

Planning depends on the required cell quantity, proliferation rate and acceptable cell age. A larger volume jump does not necessarily save time if it creates a prolonged adaptation period. Similarly, the fastest-growing preculture is not automatically the best production inoculum. Transfer criteria should reflect the intended cellular function, such as productivity, morphology or the capacity for further expansion.

Used in these chapters · 5
Back to the term directory

Selection bias

Selection bias arises when selection of observed or reported units systematically misrepresents the intended target population. Selection can occur before measurement or after results have been inspected.

Reporting only successful cultures or retrospectively choosing the best days can overstate process performance. If the highest measured result is used to select a condition, new independent confirmation is particularly important. Selection rules and excluded data are therefore documented transparently.

Foundations: How to confirm DOE results

Used in these chapters · 1
Back to the term directory

Self-shading

Related search terms: Biomass shading

Self-shading occurs when cells absorb or scatter incoming light and thereby alter the radiation environment experienced by other cells. Increasing biomass or optical path length often reduces direct illumination deeper within the culture. The strength of the effect also depends on pigment content, cell shape and the light source spectrum.

The effect is not exclusively harmful: some shielding can protect individual cells from excessive exposure. Too much shading, however, creates large poorly illuminated regions. Optimum cell density therefore cannot be inferred from making the culture appear as clear or as dark as possible. What matters is the distribution of productively usable radiation relative to the biomass present and its movement through the light field.

Used in these chapters · 2
Back to the term directory

Sensible heat

Related search terms: sensible heat

Sensible heat is an energy-transfer contribution that changes temperature without the phase change under consideration. With approximately constant heat capacity, Q = m cₚ ΔT applies to a defined mass.

Heating a bioreactor requires appropriate masses and heat capacities for medium, vessel and connected equipment. Sensible energy alone includes neither heat losses nor evaporation or condensation enthalpy. A shorter heating time increases required power.

Foundations: Steam Consumption of Plant Items · Heat Transfer

Used in these chapters · 4
Back to the term directory

Sensitivity analysis

Related search terms: sensitivity analysis

Sensitivity analysis examines how a model result changes when selected inputs or assumptions change. It helps identify uncertainties that matter to the decision. State the variations considered and quantities held constant.

In a bioreactor comparison, a larger annual batch programme may reverse the cost ranking. This establishes no probability for that development. Sensitivity analysis reveals dependencies rather than proving that the changed assumption will occur.

Used in these chapters · 4
Back to the term directory

Sensitivity coefficient

A sensitivity coefficient describes how strongly the result of a measurement model changes for a small change in an input quantity. In linear uncertainty propagation it is the partial derivative evaluated at the working point.

For mass m = V·c, sensitivity to c is V and sensitivity to V is c. Coefficients carry the corresponding units. Large changes or pronounced nonlinearity may require calculations beyond local linearisation.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Back to the term directory

Sensor drift

Sensor drift is a time-dependent change in indication caused by altered properties of the measuring system rather than the quantity being measured. Ageing, electrolyte changes or deposits can contribute in bioprocess applications. Drift may affect the zero point, sensitivity or several parts of the response curve.

It is particularly consequential when a controller compensates for the apparent deviation through real intervention: a drifting pH probe may trigger unnecessary base addition. Demonstration requires independent comparisons under suitable conditions. Disagreement between inline and laboratory values does not by itself establish drift, because degassing, temperature and sampling also matter. Reference checks before and after use help constrain its development.

Back to the term directory

Sequence coverage

Extent of a construct actually represented by sequence observations. Confirming one segment does not automatically establish an unchanged complete sequence.

Bank or construct assessment requires coverage matching functionally important regions. Unexamined intervening regions remain explicitly unverified rather than being inferred from matching ends.

Foundations: Addgene

Back to the term directory

Sequencing batch reactor

Related search terms: SBR

An SBR performs sequential treatment steps such as filling, reaction, settling and decanting in the same reactor. The precise sequence and possible overlap depend on the particular process configuration.

The material balance therefore follows the phases and changing inventory. Nominal daily average flow describes neither instantaneous loading nor oxygen demand in each phase. Settling and export behaviour belong to biological performance assessment because they affect retained solids inventory.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Serum-free medium

Related search terms: SFM

A serum-free medium contains no added serum. It must supply the functions required by the particular culture through other components, such as defined nutrients, binding proteins or growth factors. Removing serum can improve compositional control and simplify separation of the target product, but the outcome depends on the replacement formulation.

Serum-free does not necessarily mean protein-free, chemically defined or free of ingredients of animal origin. These properties need separate examination. A cell line previously cultured with serum will not automatically tolerate a switch without changing. Growth rate, attachment and product attributes can shift, so suitability remains a property of the specific combination of cells and medium rather than of the serum-free label alone.

Back to the term directory

Service Level Agreement (SLA)

Related search terms: SLA, service agreement

A Service Level Agreement describes agreed services and measurable conditions for delivering them. It may include coverage hours, response objectives, responsibilities and exclusions. The term alone guarantees no particular restoration time.

For bioreactor equipment, distinguish first response, diagnosis, parts provision, repair and return to service. Relevant objectives must fit process dependencies. Rapid contact can coexist with a repair period too long for the running culture.

Foundations: BioFlo 320 Performance Plans

Used in these chapters · 2
Back to the term directory

Setpoint

A setpoint is the desired target for a control loop, such as a culture temperature of 30 °C or a specified pH. It is compared with the measured process value to establish the control error. A setpoint may remain fixed, follow a ramp or belong to a phase-dependent process recipe.

It expresses an operating intention rather than evidence that the target is achieved. Permitted deviations, alarm thresholds and technical safety limits are separate decisions. Percentage values particularly require an explicit reference, such as the basis of oxygen saturation. Abrupt setpoint changes can provoke large actuator movements; constrained transitions therefore often use controlled rates and clearly defined phase conditions.

Used in these chapters · 19
Back to the term directory

Shear rate

Shear rate describes how rapidly neighbouring layers of fluid deform relative to one another. In simple planar shear flow, it equals the velocity gradient perpendicular to the flow direction and has units of s⁻¹. It is therefore neither a velocity in m/s nor a force; the corresponding mechanical stress also depends on the fluid's rheological behaviour.

Shear rate varies across a bioreactor and over time, particularly near moving components or narrow passages. Impeller speed cannot consequently be converted into a single biological exposure without a flow model. Duration and repetition also matter for sensitive cells or aggregates. A spatial average can hide brief local peaks and does not fully describe their potential biological consequences.

Used in these chapters · 2
Back to the term directory

Shear stress

Shear stress is a force acting tangentially per unit area and is expressed in pascals. For a Newtonian liquid in simple shear flow, τ = μ · γ̇, where dynamic viscosity μ is in Pa·s and shear rate γ̇ in s⁻¹. The same shear rate therefore produces greater viscous shear stress in a more viscous liquid.

Real reactor stresses vary spatially, and this simple relation alone does not fully characterise turbulent or complex flow. Cell size, shape, attachment and exposure history also affect potential damage. One universal shear limit should therefore not be applied indiscriminately to different cultures. Comparisons need to identify the stress quantity, location and exposure period being considered.

Used in these chapters · 2
Back to the term directory

Shear thickening

Related search terms: shear-thickening

During shear thickening, apparent viscosity increases with shear rate over the evaluated range. An appropriate flow curve establishes the behaviour.

Increasing torque alone does not prove shear thickening because speed, flow and geometry also contribute. Material interpretation requires distinguishing those contributions. The simple power-law exponent exceeds one for this behaviour. Establishing it requires a documented measurement range and assessment of artefacts such as temperature change or unsuitable geometry. It is not synonymous with viscosity increasing over time at unchanged shear rate; that requires examination of loading history.

Foundations: Viscosity

Back to the term directory

Shear thinning

Related search terms: shear-thinning

During shear thinning, apparent viscosity decreases as shear rate increases under the evaluated conditions. Shear stress may nevertheless continue increasing.

Shear thinning does not establish time-dependent structural breakdown or gentle cellular loading. Relevant ranges can differ between agitation, pumping and measurement. In a power-law model, 0 < n < 1 represents this behaviour. Shear stress still increases with shear rate while its ratio to shear rate decreases. Falling apparent viscosity therefore does not imply that increasing shear rate automatically reduces mechanical power dissipated in the material.

Foundations: Viscosity

Used in these chapters · 3
Back to the term directory

Sieving coefficient

Related search terms: product sieving, sieving, S_P, sP

An observed sieving coefficient is the concentration of a specified substance in permeate divided by an explicitly defined reference concentration, such as the well-mixed reactor. It is dimensionless and uses the same analytically defined substance form.

With changing conditions, samples and transport delay must align. Binding and additional inventories can limit a simple stationary comparison. Low product sieving gives lower instantaneous product outflow at the same liquid harvest; it does not directly describe biological formation.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems

Used in these chapters · 8
Back to the term directory

Single-use bioreactor

Related search terms: SUB

A single-use bioreactor has a product-contact culture vessel intended for one defined use, often a plastic bag or a rigid polymer vessel. The supporting structure, drive and other technical components may remain reusable. Single-use therefore describes the contact vessel's use pattern, rather than necessarily the whole instrument or a particular mixing technique.

Selection requires consideration of shape stability, material compatibility, pressure limits, connections and the hydrodynamic operating window. A bag needs appropriate support, and its nominal capacity is not automatically a suitable culture volume. Low wall mass alone does not determine heat transfer independently of the support and contact surfaces. Overall cost and environmental comparisons require a defined process and use scenario.

Used in these chapters · 3
Back to the term directory

Site acceptance test (SAT)

Related search terms: site acceptance testing

A site acceptance test examines delivered equipment after installation at its intended operating location against agreed criteria. It can reveal transport damage, assembly deviations and problems with actual utilities or interfaces. It therefore complements tests conducted under different conditions at the manufacturer's premises. Site-dependent functions merit particular attention.

SAT does not have to repeat every factory test. The key questions are which properties transport, reassembly or local connections could affect and what evidence remains missing. Successful site acceptance also does not automatically authorise every production process. Contractual acceptance, qualification and process release may have different objectives and responsibilities. A clear test plan makes these boundaries visible and prevents important supplier–operator interfaces from remaining unexamined.

Used in these chapters · 2
Back to the term directory

Skewness

Skewness describes a form of distributional asymmetry. Moment-based skewness is the third central moment divided by standard deviation cubed, provided the required moments exist.

Positive and negative values distinguish the direction of weighted asymmetry. Zero does not generally prove symmetry. Estimates can vary considerably in small process samples; histograms, data origin and possible subpopulations are considered additionally.

Foundations: Measures of skewness and kurtosis

Back to the term directory

Sliding-mesh method

A sliding-mesh method represents relative motion of rotating and stationary computational regions through a moving interface. Exchanged fluxes must remain conservative.

The method alone does not guarantee correct flow prediction. Mesh, time step, turbulence model and boundary conditions still need assessment alongside experimental comparability of the quantities of interest. Reducing time step and refining spatial resolution examine different numerical error sources; a single stable run does not verify both. A comparison checks whether relevant periodic or local quantities continue to change under justified refinement and whether calculated material and momentum balances remain consistent throughout the motion.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Back to the term directory

Soft sensor

Related search terms: virtual sensor

A soft sensor estimates a quantity that is not measured directly or continuously from available process data. Gas balances, feed quantities and earlier biomass measurements may, for example, support a current biomass estimate. The underlying model can be mechanistic, statistical or a combination of both.

Soft sensors can bridge gaps between laboratory analyses and provide additional control information. Their output remains a model-dependent estimate. Faulty inputs, unfamiliar metabolic changes or operation outside the investigated range can create systematic deviations. Dependable application requires independent reference data, documented model versions and detection of unsuitable input conditions. A strong fit to historical data does not demonstrate reliable prediction of new batches.

Used in these chapters · 2
Back to the term directory

Software Bill of Materials (SBOM)

Related search terms: SBOM

A Software Bill of Materials identifies included software components and their relationships. It exposes the components on which an application depends. Meaningful assessment requires association with the product and version actually deployed.

For bioreactor control, an SBOM can help assess the significance of a reported component change. It proves neither freedom from defects nor process suitability. Responsible personnel, assessment of affected functions and a controlled route for necessary changes remain essential.

Foundations: Software Bill Of Materials

Used in these chapters · 1
Back to the term directory

Solid-state fermentation

Related search terms: SSF

Cultivation on or within a moist solid matrix with little or no freely flowing liquid. Moisture remains essential to biological activity; solid-state does not mean water-free cultivation.

Heat, moisture and gas supply can vary spatially. The process differs from a uniformly suspended liquid culture. Even for the same product, quantity and productivity comparisons need compatible substrate, moisture and volume bases.

Foundations: Aspergillus oryzae in solid-state and submerged fermentations: progress report on a multi-disciplinary project

Used in these chapters · 2
Back to the term directory

Solids retention time

Related search terms: SRT, Sludge age

In an appropriate steady balance, solids retention time is the defined solids inventory divided by its associated solids export rate. In activated-sludge treatment it describes the average retention time of the solids being balanced.

It is not generally hydraulic residence time. Cell retention and recycle can decouple liquid and solids residence. Inventory, outputs and solids definition must be consistent; biofilms or strongly variable operation may require a more differentiated description.

Foundations: Nutrient Control Design Manual

Used in these chapters · 1
Back to the term directory

Solubility product

Related search terms: Ksp, Kₛₚ

The solubility product is the equilibrium constant for dissolution of a particular sparingly soluble solid phase, formulated consistently using dissolved-species activities. Stoichiometric coefficients determine exponents in the activity product.

For calcium phosphates, multiplying total calcium by total phosphorus is insufficient. Free species, complexation and the actual solid phase must match. Exceeding an equilibrium value also does not by itself determine the rate of visible precipitation.

Foundations: 15.1 Precipitation and Dissolution

Used in these chapters · 1
Back to the term directory

Solvate

A solvate is a solid chemical form containing solvent molecules in its structure. A hydrate is the special case involving water. Solvate composition belongs to substance identity.

A different solvate may change molar mass, assay basis or introduced solvent in a formulation. Equal principal ingredient names therefore do not establish mass-for-mass interchangeability. Relevant solvent and quality limits depend on the actual application.

Foundations: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances

Back to the term directory

Sorption isotherm

A sorption isotherm describes, at fixed temperature, the equilibrium relationship between the amount taken up and an appropriate state variable of the surrounding phase. For a moisture-sensitive powder this may relate water content to water activity or equilibrium relative humidity.

Surface uptake is distinguished as adsorption; depending on the material, the measured result can include other binding and uptake processes. Temperature, equilibrium criterion and direction of humidity change therefore belong in its description. A single moisture value is not a complete isotherm and cannot determine its shape or possible hysteresis.

Foundations: Water Activity (aw) in Foods

Back to the term directory

Sparger

A sparger introduces gas into liquid through defined outlets. Drilled holes, open tube ends and porous structures create different initial conditions for bubble formation. Position relative to the impellers influences whether gas is captured and dispersed effectively or follows a short route towards the surface.

Outlet size is not the same as the eventual bubble diameter. Detachment, gas flow, surface tension, coalescence and subsequent break-up jointly determine the bubble population. Fine outlet structures can also require a higher supply pressure. A suitable sparger is therefore selected for the actual broth and gas-flow range, rather than on the assumption that smaller holes always deliver better oxygen transfer or more uniform gas distribution.

Used in these chapters · 8
Back to the term directory

Specific enthalpy

Related search terms: enthalpy

Specific enthalpy h is enthalpy per mass, combining internal energy with the pressure-volume contribution, for example in kJ/kg. Absolute values depend on reference convention; energy balances require consistent differences.

Steam-consumer inlet and outlet states must match the selected boundary. Heat released later in an external return line cannot be counted as heat already used inside the reactor.

Foundations: Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam

Used in these chapters · 5
Back to the term directory

Specific enzyme activity

Enzyme activity divided by an explicitly defined mass, often total protein mass of a preparation. A common expression is activity units per mg protein; state the activity-unit definition and protein assay.

It can track purification but is not automatically purity as a mass fraction. Inactivation, interfering sample components and assay conditions can change it. Higher specific activity with lower total activity is compatible with losses during purification.

Foundations: The International System of Units, SI Brochure · The protein cost of metabolic fluxes: prediction from enzymatic rate laws and cost minimization

Used in these chapters · 2
Back to the term directory

Specific growth rate (μ)

Related search terms: Specific proliferation rate

Specific growth rate describes biomass increase relative to the biomass already present. At constant volume, without biomass entering or leaving, a growing population follows μ = (1/X) · dX/dt. Here X is the chosen biomass concentration, for example in g/L, and t is time in hours; μ then has units of h⁻¹.

This quantity distinguishes relative proliferation from absolute production. A large culture can generate more biomass per hour despite having a lower specific rate. Where cell loss or death occurs, the observed concentration increase initially gives a net rate. The measurement basis and volume changes also require attention, otherwise dilution may be mistaken for slower biological growth.

Back to the term directory

Specific heat capacity

Specific heat capacity describes the energy per unit mass and temperature change required for heating under stated conditions. Its unit is J/(kg·K). Values at constant pressure and constant volume are distinguished. Over a limited temperature range without a phase change, an average heat capacity can be used in Q = m·c·ΔT.

A synthetic medium of 200 kg, with an assumed c of 4.0 kJ/(kg·K), requires 8,000 kJ for a 10 K temperature increase. This medium-only calculation excludes the vessel wall, heat losses and evaporation. A heating schedule must account for those contributions separately. Heat capacity alone also cannot determine heating time: the actual transferable power is required.

Foundations: OpenStax University Physics 2: Heat transfer, specific heat and calorimetry

Used in these chapters · 2
Back to the term directory

Specific interfacial area

Specific interfacial area a is phase-interface area divided by an explicitly stated reference volume. Its dimension is inverse length. In gas-liquid systems, the denominator may be liquid volume or total dispersion volume, producing different numerical values for the same physical interface.

Within kLa, a supplies the area contribution to the transfer parameter. Measuring the product does not independently determine a. Gas hold-up alone is insufficient because the same gas volume can be distributed among different bubble sizes. A geometrical estimate requires bubble size, distribution and shape together with a consistent volume basis for the calculation.

Used in these chapters · 1
Back to the term directory

Specific product formation rate (qP)

Related search terms: Cell-specific productivity

Specific product formation rate relates product formed to the biomass present and the elapsed time. At constant volume without product inflow or outflow, qP = (1/X) · dP/dt can be used. With product concentration P and biomass concentration X in g/L, and time in hours, the units are g product/(g biomass · h).

This simple expression describes observed net accumulation. If product is simultaneously degraded or adsorbed onto surfaces, actual formation is higher. Cell culture also uses units such as picograms per cell per day. High qP can occur at low cell concentration; total reactor performance therefore requires considering specific activity and the available quantity of productive cells together.

Used in these chapters · 2
Back to the term directory

Specific substrate uptake rate (qS)

Related search terms: Specific substrate consumption rate

Specific substrate uptake rate describes substrate consumption per amount of biomass per unit time. At constant volume without material inflow or outflow, qS = −(1/X) · dS/dt. With S and X in g/L and time in hours, the units are g substrate/(g biomass · h). The minus sign makes the value positive when substrate concentration falls.

This expression assumes that the decrease actually represents biological uptake. Chemical degradation, evaporation or adsorption would distort the estimate. qS helps compare the metabolism of cultures containing different cell quantities, but it is not equivalent to growth: consumed substrate can also support maintenance or product formation. Using cell number as the reference changes the units accordingly.

Back to the term directory

Spin-off

Related search terms: spin-off, spin-out

A spin-off is a newly formed organisation emerging from an existing organisation or its activities. In research, developed technology, knowledge or rights may be transferred into a separate company. Describe the relationship from the actual founding circumstances.

University origins do not automatically establish product maturity or supply capability. Biological evidence, technical scope and current offering remain separate questions for bioreactor technologies. The term is not a general quality label for every company with scientific contacts.

Used in these chapters · 1
Back to the term directory

Stainless-steel bioreactor

A stainless-steel bioreactor uses a vessel made from a corrosion-resistant steel alloy selected for its intended service. This construction can accommodate different vessel sizes, agitators, connections and heat-transfer surfaces. Stainless steel is a family of materials, rather than a complete specification of chemical resistance or surface condition.

Alloy, fabrication, welded joints and actual operating conditions jointly determine suitability. Corrosion remains possible when conditions are unfavourable. Opaque walls also place greater reliance on appropriate measurements and other observations when assessing the culture. A large metal vessel is not automatically an enlarged laboratory apparatus: heat-transfer area per unit volume, shaft mechanics and the distribution of supply can change substantially with size.

Back to the term directory

Standard deviation

Related search terms: Sample standard deviation

Standard deviation is the square root of variance and describes variation in the same unit as the quantity. A sample standard deviation estimates variation in a specified population under appropriate assumptions.

Variation between individual reactor runs is not the uncertainty of their mean. Technical repeats also estimate a different variation from independent cultures. The level and denominator used must therefore be apparent alongside the numerical value.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 10
Back to the term directory

Standard error

Related search terms: Standard error of the mean, SE

A standard error is an estimated standard deviation of an estimator’s sampling distribution. For the mean of independent identically distributed observations, the usual estimate is s/√n.

This formula does not apply unchanged to arbitrarily correlated time points or technical repeats from one culture. More data points can increase nominal n without providing proportionately more independent information. Standard error also does not describe total measurement uncertainty including shared systematic contributions.

Foundations: 4.1.4.1 Linear Least Squares Regression · Evaluation of measurement data — Guide to the expression of uncertainty in measurement · Assessing independence of random errors

Used in these chapters · 6
Back to the term directory

Standard uncertainty

Related search terms: relative standard uncertainty

Standard uncertainty expresses an uncertainty contribution on the scale of a standard deviation, allowing consistent combination through a suitable measurement model.

It is not simply the spread of displayed readings. A repeatedly measured sample may vary little while a shared calibration correction remains uncertain. Required contributions follow from the intended measurand. A synthetic concentration contribution of 0.20 g/L expressed as standard uncertainty is weighted by its sensitivity coefficient; it is not automatically added as a maximum possible error.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 10
Back to the term directory

Stationary point

A stationary point of a differentiable function has a zero gradient. This is a necessary condition for an interior local extremum under the corresponding differentiability assumptions.

The point may instead be a saddle or another flat state. It is not the same as steady-state reactor operation. An optimum with bounded factors may also lie on a boundary and need not have a zero unconstrained gradient there.

Used in these chapters · 1
Back to the term directory

Statistical interaction

Related search terms: Interaction, Interactions, Interaction effect, Interaction effects, Statistical interactions

An interaction occurs when the effect of one factor depends on the value of another. A product term such as A·B can represent this dependence within the studied region.

Non-parallel conditional effect lines can make this relationship visible. Its practical importance depends on magnitude and uncertainty. A statistical interaction term does not by itself identify a biological mechanism; that explanation requires additional scientific evidence.

Foundations: Interaction effects matrix plot

Used in these chapters · 5
Back to the term directory

Statistical residual

Related search terms: Residual, Residuals, Regression residual, Regression residuals, Statistical residuals, residuals, residual, regression residual, regression residuals, statistical residual, statistical residuals

A residual is an observed value minus its fitted model value. It contains random deviations and potentially contributions that the model systematically fails to describe. A balance residual compares the observed inventory change with the change predicted from the accounted streams and reactions.

Residuals are examined against predictions, factor values, time and run order. Patterns may indicate curvature, changing variation or temporal dependence. Small residuals on the fitting data do not establish good prediction for new independent runs.

Foundations: 4.4.4 How can I tell if a model fits my data? · How can I detect non-constant variation across the data?

Used in these chapters · 22
Back to the term directory

Steady state

A steady state exists when the macroscopic variables under consideration show no systematic change over a suitable observation period. In continuous culture, biomass, residual substrate and product concentrations may remain constant despite ongoing conversion and exchange of material. Steady state therefore represents balanced inflow, outflow and reaction rather than inactivity.

The variables, tolerances and observation period required depend on the question being investigated. A smoothed sensor trace alone cannot establish stationarity. Slow genetic adaptation or changes in product quality can occur while biomass remains constant. This operating condition must also be distinguished from the stationary growth phase of a batch culture with restricted resources.

Used in these chapters · 6
Back to the term directory

Steady-state gain

Related search terms: static gain

Steady-state gain describes the ratio of a settled output change to the input change causing it at a specified operating point. Its unit is output unit divided by input unit; it is dimensionless only with appropriate variables or normalisation. The sign indicates whether input and output changes have matching or opposite directions.

Sensor characterisation must therefore retain raw values and the imposed change. Independently normalising two traces to their own endpoints can produce matching dynamics despite different gains. A suitable time constant does not replace calibration. In nonlinear systems, gain may also depend on operating point and the size of the applied change.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

Steam dryness fraction

Related search terms: dryness fraction, dryness value

In a saturated two-phase model, dryness fraction x is vapour mass divided by total water-steam mixture mass. A value of 0.95 means 95% vapour and 5% liquid by mass, not 95% chemical purity.

A real dryness-value result requires its test method. Dryness, non-condensable gases, superheat and chemical quality are separate characteristics, none substituting for evidence of the others.

Foundations: What is Steam?

Used in these chapters · 1
Back to the term directory

Steam quality

Related search terms: sterilising steam quality

Steam quality for sterilisation includes both physical properties and chemical cleanliness. Non-condensable gases can obstruct contact, while superheated steam initially behaves differently from saturated steam. Excessive entrained water can affect the load and condensate handling. Unwanted substances from generation or distribution can also reach contact surfaces.

Suitable temperature and pressure are therefore not a complete quality specification. Required characteristics and acceptance limits depend on the intended use and quality context. Pharmaceutical applications involving direct contact have particular requirements that cannot be transferred automatically to every heating-steam circuit. Equally, chemically clean steam can be distributed in a physically unsuitable way. Purity and effective process delivery must therefore be considered together when assessing the utility.

Used in these chapters · 7
Back to the term directory

Steam trap

Related search terms: condensate trap

A steam trap removes condensate from a steam system while limiting unwanted live-steam passage according to its design. Performance depends on load, available pressure differential, backpressure and suitable air removal.

Nominal pipe size or a warm drain alone does not establish adequate performance everywhere. Consider start-up, operating load and the entire return path together. Select the actual trap type for its application.

Foundations: Steam Quality

Used in these chapters · 1
Back to the term directory

Step response

A step response is the output trajectory following a prescribed abrupt input change. Step magnitude, initial state and timing are part of the experiment.

In a sensor test, the change must actually reach the sensing element. A valve command without knowledge of tubing and mixing does not establish the effective input. Responses to different step magnitudes can be normalised for comparison when an ideal linear system retains the same parameters. Raw values still matter: independently normalising each trace to its own endpoints can hide differences in steady-state gain or an incorrectly selected final state.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 2
Back to the term directory

Sterile tubing welding

Related search terms: tube welding

Sterile tubing welding joins suitable thermoplastic tubes using a process designed for that purpose. Controlled thermal treatment produces a continuous fluid connection without exposing the internal paths as an open assembly operation would. It can enable transfers between closed containers and reduce the number of open manipulations.

Tubing material, outside diameter, wall thickness and condition must match the welding equipment and approved procedure. Not every silicone tube can be welded as a thermoplastic. Claims established for dry lines must not be transferred uncritically to liquid-filled lines. An apparently uniform weld does not by itself demonstrate microbiological suitability. Strength, passage continuity and barrier performance require assessment for the application, together with weld position and subsequent mechanical loading.

Back to the term directory

Sterilisation

Related search terms: sterilising treatment

Sterilisation is a process intended to render a material or system sterile. This may be achieved by inactivating microorganisms or, for suitable liquids, by validated physical removal. The process must suit the initial microbial burden, the material and the most challenging intended load. A specified treatment therefore cannot be transferred uncritically to different vessels or fill volumes.

Effectiveness requires every relevant location to experience the necessary conditions. Afterwards, a suitable barrier must prevent recontamination. Sterilisation does not necessarily eliminate chemical residues, endotoxins or every other biologically active component. Choosing between heat, filtration and other methods therefore involves microbial effectiveness, product stability and the way the material will subsequently be handled, stored or connected to the process.

Used in these chapters · 22
Back to the term directory

Sterilisation in place (SIP)

Related search terms: steam in place

Sterilisation in place treats equipment or a defined section of equipment while it remains in its installed position. Saturated steam is commonly used, in which case SIP is also called steam in place. Steam must reach the intended contact surfaces while air and condensate are adequately removed. Critical locations often include drains, fittings and poorly connected sections of pipework.

A temperature measurement in the vessel alone does not demonstrate treatment of the entire system. Monitored positions need a defensible relationship with the most challenging locations. Integrity remains important after treatment, for example during cooling and when connecting further components. SIP is not a cleaning procedure; existing deposits may obstruct contact and adversely affect heat transfer.

Used in these chapters · 7
Back to the term directory

Sterilisation validation

Related search terms: validation of sterilisation

Sterilisation validation provides documented evidence that a defined procedure reliably achieves its intended sterilising effect under specified conditions. It identifies the materials, loads and critical locations being treated. Physical measurements and, where appropriate, suitable microbiological challenges establish whether the most difficult intended conditions are adequately controlled. The most favourable routine case is not sufficient by itself.

For a reactor, maximum fill volume, long connection lines or trapped air can change the challenge. Validation must therefore match its actual configuration. Repeatable measurements are insufficient if the selected measurement locations miss the critical areas. Changes to the recipe, components or loading may require reassessment. The extent of formal documentation depends on the application and its quality requirements.

Used in these chapters · 2
Back to the term directory

Sterilising filtration

Related search terms: sterile filtration

Sterilising filtration removes viable microorganisms from a suitable liquid or gas using a filter system qualified for that purpose. Membranes nominally rated at 0.2 or 0.22 micrometres are common in many bacterial-retention applications. Nominal pore size alone, however, does not establish complete process performance. Relevant factors include membrane material, product, pressure, temperature, duration and microbial challenge.

Downstream lines and containers must also be maintained in an appropriately protected condition; otherwise successfully filtered liquid can immediately become contaminated again. Product substances may adsorb to the filter or change its material. Sterilising filtration is not a general method for removing viruses, mycoplasma or dissolved endotoxins. Each of those objectives requires separate retention and suitability evidence for the actual system.

Used in these chapters · 3
Back to the term directory

Sterility

Related search terms: sterile state

Sterility is the absence of viable microorganisms. It describes a condition rather than simply confirming that a sterilisation procedure has been performed. Because testing examines only a limited part of a system, a small number of negative samples cannot prove sterility. Assurance instead depends on a suitable, controlled process and subsequent preservation of the protective barrier.

In microbial cultivation, previously sterile medium is deliberately inoculated with the production microorganism. The resulting culture is no longer microorganism-free but should remain free from unwanted organisms. This statement does not automatically apply to inoculation with animal cells. Sterility also does not mean chemical purity or freedom from endotoxins. This distinction prevents a successfully heated component from being incorrectly regarded as free from all biological residues, chemical contamination or other material capable of affecting the process.

Used in these chapters · 9
Back to the term directory

Sterility assurance level (SAL)

Related search terms: sterility assurance

In the context of a sterilisation process, the sterility assurance level expresses the probability that an individual treated unit still carries a viable microorganism. At a SAL of 10⁻⁶, the modelled probability of a treated unit being non-sterile is at most 10⁻⁶; this does not guarantee a maximum count within a particular million units. It is supported by an appropriate evidence strategy, rather than by actually testing one million units.

SAL is neither the microbial count in a culture nor an acceptable proportion of contaminated production batches. An aseptically assembled process also does not automatically acquire a particular SAL merely because its components were sterilised. The claim must fit the material, treatment and unit considered. A regulatory target for medicinal products cannot be transferred automatically to scientific laboratory operations.

Used in these chapters · 4
Back to the term directory

Stirred-tank bioreactor

Related search terms: STR

A stirred-tank bioreactor circulates its culture liquid using a mechanically driven impeller. Large circulation loops redistribute material throughout the vessel, while smaller flow structures mix neighbouring fluid regions. When gas is supplied, the impeller can also break up and distribute bubbles. Impeller geometry, diameter, position and vessel internals therefore determine performance together.

This reactor family accommodates many cultures when agitation, gas delivery and heat removal suit the process. A stirred tank is not automatically an ideally mixed reactor: viscous broth, tall vessels or rapid consumption can produce substantial local differences despite visible motion. The name describes the physical construction, rather than a cultivation mode or a guaranteed level of cell protection.

Used in these chapters · 11
Back to the term directory

Stock solution

Related search terms: concentrated stock

A stock solution contains a defined component or mixture at a concentration intended for subsequent additions. Quantitative use requires identity, assay, reference basis and amount actually delivered.

A concentrated stock is not automatically a complete culture medium. Local addition can affect mixing, pH and ionic loading. Equal pump volumes from different stocks may deliver different solute and solvent amounts. For example, changing from mol/L to mass percent requires solution density if the same volumetric dosing pump continues to be used.

Used in these chapters · 1
Back to the term directory

Storage modulus

Shear storage modulus G′ describes the elastically stored contribution during linear oscillatory shear testing. Its unit is Pa.

A value needs at least frequency, temperature and tested amplitude range. A high storage modulus at one frequency is not a universal statement about pumpability, cellular tolerance or steady flow. In a sinusoidal linear test, G′ represents the stress component in phase with strain. Its value is considered together with G″. A crossover between the moduli at one frequency is initially a dynamic observation, not automatically a chemical gel point or a universal material transition.

Foundations: Determining the Linear Viscoelastic Region in Oscillatory Measurements, RH107

Back to the term directory

STR profiling

Related search terms: STR profile

Comparison of short repeated DNA regions at specified genomic positions to characterise or identify material. For human cell lines, a suitable profile compared with an appropriate reference can help detect mix-ups.

It is not a universal identity test for every species or production clone. A matching sample profile also does not prove the withdrawn vial was correctly associated. Reference, tested positions, interpretation and sample linkage must match the question.

Foundations: ATCC Animal Cell Culture Guide

Used in these chapters · 1
Back to the term directory

Stress sweep

A stress sweep varies applied stress according to a defined time programme while measuring deformation or flow. It can investigate apparent yield behaviour.

Ramp rate, holding time and sample history affect interpretation. Report an observed transition with its protocol, rather than as a method-independent material constant. Distinguish a continuously increasing stress, held steps and oscillatory variation. These programmes ask different questions of a time-dependent sample. In living or structurally evolving suspensions, previous loading can also affect the next measurement; equal final stress does not establish equal history or an equivalent sample condition.

Foundations: Rheological Techniques for Yield Stress Analysis, RH025

Back to the term directory

Structural variation

Structural genomic variation involves larger DNA regions, such as their deletion, additional copies, reversed orientation or relocation. A size threshold is an analytical convention; it does not replace a description of the actual sequence and position affected.

In production cell lines, different methods detect different types or sizes of these changes. An unremarkable test therefore supports only the properties covered by its scope and detection capability. A stability comparison should document the reference population, variant types examined and functional process data together.

Foundations: NHGRI: Structural variation

Back to the term directory

Student’s t distribution

Related search terms: t distribution

Student’s t distribution is symmetric and indexed by a degrees-of-freedom parameter. It arises, for example, as a standard normal variable divided by the square root of an independent chi-square variable divided by its degrees of freedom.

Under appropriate assumptions it supports tests and confidence intervals when variation is estimated. Small degrees of freedom produce heavier tails than a normal distribution. Choosing a t distribution does not retrospectively make dependent culture observations independent.

Foundations: t distribution

Back to the term directory

Substrate

Related search terms: Process substrate

In bioprocessing, a substrate is a substance biologically converted by cells or enzymes. During cultivation, the term commonly denotes nutrients supporting growth, energy metabolism or product formation, such as glucose serving as a carbon source. Concentrations, yields and consumption rates must specify which substance is being considered. Media usually contain several utilisable compounds, so the designated substrate is not necessarily the only nutrient or the one currently limiting growth.

High concentrations can promote inhibition, osmotic stress or unwanted metabolic pathways. A falling concentration alone does not quantify consumption because feeding, dilution and withdrawal affect the balance. In adherent cell culture, substrate can also mean an attachment surface. That supporting material must be distinguished from a metabolically consumed process substrate.

Used in these chapters · 37
Back to the term directory

Substrate inhibition

Related search terms: Inhibitory substrate concentration

Substrate inhibition occurs when raising a substrate concentration slows biological conversion even though the same substrate is required at an appropriate level. Possible causes include direct interactions with enzymes, membrane effects or a stressful chemical environment. This concentration effect differs from simple saturation, where the rate stops increasing but does not decline.

A larger initial nutrient charge therefore does not automatically support better performance. Local concentration peaks can matter even when the average concentration appears acceptable. The cause of an observed inhibition must nevertheless be assigned carefully. If substrate addition also raises osmolality or changes pH, those changes may account for part of the response rather than the substrate acting directly on the conversion pathway.

Used in these chapters · 2
Back to the term directory

Sunk cost

Related search terms: sunk costs

Sunk costs are incurred expenses that the present decision can no longer change. Comparing future alternatives distinguishes them from changeable payments and possible sale proceeds.

Past purchase alone does not justify continued equipment use. Future maintenance, avoided replacement and displaced alternative use may matter. This distinction concerns the decision, not whether historical expenditure remains documented.

Foundations: 10.1 Identify Relevant Information for Decision-Making

Back to the term directory

Superficial gas velocity

Related search terms: SGV, uG

Superficial gas velocity is gas volumetric flow divided by the complete cross-sectional area being considered: uG = QG/A. Using QG in m³/s and A in m² gives m/s. Superficial means referenced to the empty cross-section; it is neither a velocity at the liquid surface nor the actual rise speed of individual bubbles.

The quantity helps compare gas loading between different columns or vessels. The temperature and pressure basis of the gas flow must be stated, particularly in tall liquid columns. Equal superficial gas velocity nevertheless does not ensure identical bubble populations. Sparger design, liquid properties and column diameter still influence the flow regime and the mass transfer achieved.

Used in these chapters · 1
Back to the term directory

Superficial liquid velocity

Superficial liquid velocity is liquid volumetric flow divided by the full geometric cross-section, as though no particles occupied it. Its unit is m/s.

Average velocity through accessible pore space can be larger. For a simple saturated bed with void fraction ε, upore = usuperficial/ε; partial wetting and complex flow require a more detailed description. For a fully saturated porous cross-section, an appropriately averaged pore velocity follows by dividing superficial velocity by void fraction. With multiple phases, liquid occupancy requires separate treatment. This cross-sectional quantity describes neither local constrictions nor the complete distribution of individual particle or cell pathways.

Foundations: Average Linear Velocity

Used in these chapters · 1
Back to the term directory

Superheated steam

Related search terms: superheat

Superheated steam has a temperature above the saturation temperature at its pressure. Before corresponding condensation, it must release heat and reach saturation.

High steam temperature alone therefore does not establish effective moist heat transfer at a target surface. State after pressure reduction depends on inlet conditions and the transformation; it is not invariably saturated or invariably superheated. Assessment therefore compares temperature and absolute pressure at the same relevant location, not arbitrarily combined supply-line and reactor readings.

Foundations: Superheated Steam

Used in these chapters · 1
Back to the term directory

Supersaturation

A solution is supersaturated with respect to a specified phase when its composition exceeds the corresponding equilibrium state under stated conditions. A concentration ratio c/c_sat can express this for suitable systems. For ionic solids the activity quotient corresponding to the dissolution reaction must instead be considered.

Supersaturation is a thermodynamic driving force, not a timing prediction. Nucleation may be delayed, while temperature, pH, complexation and common ions affect the relevant solubility. A clear stock solution is therefore not automatically storage-stable, and one solubility value cannot replace assessment of the complete medium matrix.

Foundations: 11.3 Solubility · 15.1 Precipitation and Dissolution

Used in these chapters · 1
Back to the term directory

Surface roughness

Related search terms: Ra value

Surface roughness describes small-scale height variations on a surface. The commonly used Ra parameter is the arithmetic mean of absolute profile deviations from a mean line over the evaluation length, expressed for example in micrometres. It reduces a measured profile structure to a single number. Measurement direction, filtering and evaluation length affect comparability.

Two surfaces with the same Ra may have different grooves, peaks or isolated deep defects. A low Ra value alone therefore proves neither good cleanability nor suitable corrosion resistance. Welds, crevices and material condition also require assessment in a bioreactor. A useful specification identifies the measurement procedure and relevant region; a reading from an accessible position does not automatically represent every internal surface.

Back to the term directory

Suspension culture

Related search terms: Cell suspension

In suspension culture, cells or cell aggregates remain within the liquid medium rather than requiring a solid surface for growth. This growth form can simplify distribution and expansion of culture volume. Cells nevertheless remain biological particles: they can settle, form clusters or experience different conditions at interfaces.

The ability to grow in suspension belongs to the particular cell population and its culture environment. Simply increasing agitation does not reliably convert an anchorage-dependent line into a suspension line. Successful adaptation may also change cellular characteristics. Process comparisons should therefore establish whether the culture consists mainly of individual cells, small clusters or larger aggregates, since these structures influence nutrient access and growth in different ways.

Used in these chapters · 4
Back to the term directory

System boundary

Related search terms: Control volume

The system boundary specifies which part of a plant a balance covers. It may surround the culture liquid alone or also include the headspace and an external loop. A control volume is the bounded region through which material and energy may flow. Its boundary need not coincide with a physical vessel wall.

Sampling removes material from the culture liquid. If the sealed sample vessel remains inside the larger system being analysed, that transfer is initially internal. Every interpretable balance therefore needs a boundary sketch, identified inventories and an explicit sign convention. Otherwise identical measurements can appear to imply different losses simply because the accounting boundaries differ.

Foundations: MIT: Definitions and fundamental ideas of thermodynamics

Used in these chapters · 23
Back to the term directory

System curve

Related search terms: system curve

A system curve describes the head or pressure difference required by a connected flow system as a function of volumetric flow. Static contributions and flow-dependent losses are combined.

Its intersection with an appropriate pump curve can identify a steady operating point. Closed valves, fouled heat exchangers or changed piping routes alter the system curve. The operating point therefore belongs jointly to the pump and the current system condition.

Foundations: Improving Pumping System Performance: A Sourcebook for Industry

Back to the term directory

T

Tangential flow filtration (TFF)

Related search terms: TFF, crossflow filtration

In tangential flow filtration, feed travels along a membrane surface. Some liquid passes through as permeate while the remaining liquid forms the retentate. Flow arrangement is distinct from the membrane separation threshold.

A large recirculation flow is not an equally large harvest flow. Sizing separately considers recirculation, permeate quantity, pressures and product passage. TFF covers different membranes and duties; its name alone guarantees neither gentle cell handling nor a particular recovery.

Foundations: Shear contributions to cell culture performance and product recovery in ATF and TFF perfusion systems · KrosFlo KR2i Tangential Flow Filtration System

Used in these chapters · 4
Back to the term directory

Technical redundancy

Related search terms: redundancy

Technical redundancy provides additional functions or resources able to maintain a required task during specified failures. Its meaning needs a defined failure case and remaining capabilities. More installed rating alone does not establish independence.

Shared controls, electricity or headers can affect several units together. Storage also bridges only limited time and needs appropriate charge. Required redundancy follows from the process task rather than a universal unit count.

Foundations: Steam Accumulators · Improving Steam System Performance: A Sourcebook for Industry

Used in these chapters · 2
Back to the term directory

Technical replicate

Related search terms: Technical repeat

A technical replicate repeats a measurement or analytical step on material from the same underlying experimental unit. It can describe the repeatability of that measurement chain.

Averaging technical repeats may reduce random analytical variation. Shared calibration errors and biological variation between reactor runs do not disappear. Statistical analyses must not treat technical repeats as additional independent cultures without justification.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Back to the term directory

Technology Readiness Level (TRL)

Related search terms: TRL

Technology Readiness Levels classify development maturity using defined evidence. The widely used TRL scale ranges from observed basic principles to demonstrated operation of a mature system. A specific rating requires its framework and supporting evidence.

High maturity in one application does not establish suitability for every bioprocess. A readiness level alone also says little about price, supply capability or secured demand. Assess technical maturity, biological transferability and commercial offering separately for new reactor concepts.

Foundations: Technology Readiness Levels

Used in these chapters · 1
Back to the term directory

Temperature mapping

Related search terms: thermal mapping, mapping study

Temperature mapping examines thermal conditions at documented locations over time. It connects measurement positions and load states to a specific conclusion, such as spatial distribution or suitability of a routine probe.

Sensor count alone does not determine evidence quality. Relevant geometry, installation, dynamics and missing data matter. A lowest reading in one study is not automatically an invariant cold spot for every operating state.

Foundations: Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 6
Back to the term directory

Temperature measurement

Related search terms: Pt100, resistance thermometer

Temperature measurement determines the thermal condition at the sensor location. Bioreactors frequently use resistance thermometers, whose electrical resistance changes reproducibly with temperature. A Pt100, for example, has a nominal resistance of 100 Ω at 0 °C. The transmitter and connection arrangement influence how reliably this becomes a process-temperature reading.

Dynamic behaviour matters alongside accuracy: a thermowell, immersion depth and liquid movement can delay the response. Correctly measured jacket temperature is not automatically culture temperature. Spatial differences are particularly possible during heating and cooling. A comparison measurement therefore needs a suitable location and sufficiently stable conditions, rather than simply reading two displays at the same instant.

Used in these chapters · 4
Back to the term directory

Temperature-control jacket

Related search terms: Cooling jacket, Heating jacket

A temperature-control jacket provides a flow space around the vessel wall, separated from the culture chamber. A conditioning fluid passes through it and transfers heat through the wall into or out of the culture. Available exchange area depends on jacket geometry and on which wall regions effectively contact liquid on the culture side.

Higher jacket flow does not improve heat transfer without limit and may increase pressure loss. Culture-side circulation also needs to be adequate. Partial filling, uneven jacket flow and a small temperature difference can restrict useful duty. The jacket has its own pressure and temperature limits, which must be specified independently from the permissible conditions in the culture chamber.

Used in these chapters · 4
Back to the term directory

Thermal diffusivity

Thermal diffusivity α = λ/(ρc_p) combines thermal conductivity, density and specific heat capacity, with units m²/s. It characterises how rapidly temperature differences can relax by conduction within a material.

It is not thermal conductivity: a material may conduct well while requiring substantial energy to change temperature. Heat penetration also depends on geometry and boundary conditions. Diffusivity alone does not determine sterilisation time.

Foundations: 1.6 Mechanisms of Heat Transfer

Back to the term directory

Thermal inactivation

Related search terms: inactivation

Thermal inactivation is a heat-induced reduction of a specified biological capability, such as microbial reproductive ability or enzyme activity. The target quantity and detection method must be stated. Temperature measurement initially describes exposure, not the remaining biological behaviour directly.

Inactivation depends on the target system, medium and complete time-temperature history. A log-linear D/z model is an approximation requiring justification; mixed populations may show different survival curves. Microbial reduction also differs from endotoxin removal, and loss of enzyme activity is not evidence of sterility.

Foundations: Steam Sterilization – Guideline for Disinfection and Sterilization in Healthcare Facilities · Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 4
Back to the term directory

Thermoplastic elastomer

Related search terms: TPE

A thermoplastic elastomer, abbreviated TPE, combines elastomeric behaviour with a thermally reversible network structure. The name describes a material family rather than one chemical formulation or every property of a particular tube or component. Technical comparisons therefore require the specific material grade and product specification.

The label TPE does not establish validated sterilisation, a particular weldability or demonstrated compatibility of a complete assembly with a process fluid. Temperature, contact duration, sterilisation method, additives and connecting components belong in the actual assessment. Extractables or leachables evidence must match the material, processing history and contact situation being considered; a family name does not replace that evidence.

Foundations: Thermoplastic elastomer, TT07268

Used in these chapters · 1
Back to the term directory

Thixotropy

Thixotropy is a time-dependent viscosity decrease under shear with at least partial recovery during reduced loading or rest.

One increasing flow curve does not reliably distinguish this effect from shear thinning. A suitable protocol records duration, preshear and recovery under controlled conditions. A suitable experiment separates changes under constant loading from changes caused by selecting a new shear rate. Recovery after unloading also matters. Differences between upward and downward ramps alone are not conclusive if temperature, sample loss or measurement procedure provide alternative explanations for the observed hysteresis.

Used in these chapters · 1
Back to the term directory

Throughput

Related search terms: processing rate

Throughput is quantity processed or delivered across a defined boundary per time. It may use mass, volume or completed batches. State product condition, time window and treatment of initial and final inventory.

Ideal sustained throughput differs from the mean of a finite campaign with startup. Releasing work earlier may only increase intermediate inventory. Capacity decisions therefore consider actual outflow alongside holds and usable output.

Foundations: Basic Concepts in Queueing, lecture8

Used in these chapters · 21
Back to the term directory

Time constant

Related search terms: probe time constant

The time constant characterises the speed of an exponential response. A first-order system reaches about 63.2% of an ideal input step after one time constant; its unit is time.

Dead time and time constant are different quantities. One time constant may inadequately describe a measurement chain containing several coupled delays. For the model τdy/dt + y = u, t₉₀ = 2.303τ when no additional dead time is present. The time constant is estimated from a defined response; it is not automatically the duration of a real process event or transport time through sampling tubing.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 11
Back to the term directory

Timestamp and UTC

Related search terms: Timestamp, UTC

A timestamp assigns an event to an instant. Exchange between systems requires an unambiguous time basis. UTC is Coordinated Universal Time; an explicit UTC offset connects a local time representation to that reference. In RFC 3339 notation, the suffix Z denotes a zero offset.

The synthetic values 2026-09-10T14:00:00+02:00 and 2026-09-10T12:00:00Z describe the same instant. Consistent notation does not prove that device clocks are synchronised. Sampling, measurement and storage times also need distinguishing. Displaying milliseconds establishes no corresponding timing accuracy. These distinctions determine whether concentration, volume and process events have been combined at matching times.

Foundations: RFC 3339: Date and time on the Internet – timestamps

Used in these chapters · 15
Back to the term directory

Titration

Titration progressively adds a known reagent amount and follows the system response to determine an analytical quantity. Acid–base titrations can evaluate pH trajectories and delivered equivalents.

Endpoint, reagent assay, volume basis and possible gas losses must match the question. Buffer demand measured in an open sample may be affected by CO₂ exchange. Pump run time without calibrated delivery is not a complete titration record.

Foundations: 14.6 Buffers

Used in these chapters · 2
Back to the term directory

Tonicity

Tonicity describes the effective osmotic action of a solution across a particular cell membrane under specified conditions. Relevant factors include which solutes cross the membrane and the observation timescale.

Solutions with equal osmometer results may produce different cellular volume histories. A tonicity statement therefore requires membrane and time context; it does not follow from bulk sample osmolality alone.

Foundations: 11.4 Colligative Properties

Used in these chapters · 1
Back to the term directory

Torque

Torque describes the turning effect of a force about an axis, measured in N·m. During steady rotation, mechanical power equals torque multiplied by angular velocity.

Liquid power requires allowance for bearing, seal and other losses according to the measurement boundary. Displayed motor torque does not automatically equal input to the culture. For steady rotation, power is 2πNM with N in s⁻¹. Measured shaft torque may also include bearing, seal or acceleration contributions. Measurement boundary and a justified loss correction must therefore be established before assigning power to the liquid or dividing it by liquid volume.

Used in these chapters · 7
Back to the term directory

Total Cost of Ownership (TCO)

Related search terms: TCO, lifecycle cost

TCO combines costs considered for a defined ownership and operating scope over a stated period. It may include purchase, installation, operation, maintenance and retirement. Specify which items are included.

For bioreactors, a lower equipment price does not establish lower complete use costs. Different batch counts or excluded staff and media costs change the interpretation. TCO comparisons therefore require a common service, time and price basis.

Foundations: Bioprocess Simulation, Economics and Design, lecture10

Used in these chapters · 1
Back to the term directory

Total nitrogen

Related search terms: TN

Total nitrogen includes nitrogen in the inorganic and organic forms covered by a defined sample. It is reported as mass of the element N, regardless of the compounds containing it.

A plant balance requires appropriate total-nitrogen loads for all relevant inputs and outputs. Conversion of ammonium to nitrate alone does not remove total nitrogen. Sample preparation and coverage of dissolved and particulate fractions must be comparable between streams.

Foundations: Nutrient Control Design Manual

Used in these chapters · 4
Back to the term directory

Total vessel volume

Total vessel volume describes the geometric internal capacity of a vessel under a stated boundary convention. Drawings or specifications should clarify whether the head section, nozzles or displacement by internals are included. It describes available internal space, rather than promising that all of that space can be occupied by culture liquid.

Operation requires headspace and allowance for the expansion of aerated liquid, while useful impeller engagement also limits the working range. A large ratio of total volume to working volume does not automatically indicate a poor design: gas loading, foam behaviour or filling reserves may justify it. Calculations should use the volume relevant to the quantity being assessed, rather than the largest available capacity figure.

Used in these chapters · 2
Back to the term directory

Trace elements

Related search terms: Trace nutrients

Trace elements are needed in small amounts but can be indispensable for major cellular functions. Many act as metal components or cofactors of enzymes involved in electron transport and biosynthesis. Their importance is therefore not proportional to the mass added. A small shortage can limit the entire process even when all major nutrients are plentiful.

The biologically available form is critical. A metal may be detectable in the medium yet poorly available because of precipitation or strong binding. Conversely, excessive available concentrations can be toxic. Additional traces from water, raw materials or contact surfaces complicate interpretation, particularly when a laboratory formulation is transferred to a different production environment.

Used in these chapters · 2
Back to the term directory

Tracer recovery

Tracer recovery compares measured or balanced marker output with the introduced amount. At constant flow, output follows from integrating flow multiplied by concentration.

A curve normalised to unit area can conceal poor recovery. First assess observation duration, calibration, loss paths and the system boundary. At constant outlet flow, discharged mass is calculated by integrating Q C(t). Additional sampling outlets must be included. Normalising the observed trace to unit area can describe its shape but should not hide missing mass or a truncated tail; recovery remains a separate recorded result.

Foundations: Chapter 16: Distributions of Residence Times for Chemical Reactors

Used in these chapters · 1
Back to the term directory

Trade credit

Related search terms: trade credit

Trade credit arises when goods or services are supplied before their agreed payment. Payment period, possible early-payment discounts and consequences of late payment depend on the specific terms.

For a bioreactor retrofit, delivery, acceptance and payment can occur far apart. The payment schedule must represent these milestones. Later payment changes liquidity needs; it is not automatically free or independent of the quoted purchase price.

Foundations: 19.2 What Is Trade Credit?

Back to the term directory

Training–test split

Related search terms: Train-test split

A training–test split reserves data for later model assessment separately from model fitting and selection. An additional validation set or appropriate cross-validation may support model selection.

For bioprocesses, the complete independent run is often the appropriate splitting unit. Randomly dividing individual time points does not test the same transfer to new cultures. A test set is not repeatedly used to select favourable models without reconsidering its independent role.

Foundations: Common pitfalls and recommended practices

Back to the term directory

Transfer efficiency

Related search terms: Cell recovery

Ratio of quantity recovered at the destination to quantity supplied at the source within a described transfer boundary. Cell transfer may use viable cell numbers, whereas liquid recovery has a different numerator and denominator.

Concentration ratios do not automatically give quantity recovery when volume changes. Account separately for added liquid, retained cells and measurement basis. Do not subtract an assumed loss again when destination quantity has already been measured after transfer.

Used in these chapters · 7
Back to the term directory

Transfer function

A transfer function relates input and output in the Laplace domain for a linear time-invariant system with appropriately treated initial conditions. It describes dynamics and gain.

Identical transfer functions may arise from differently arranged internal components. An output trace therefore does not automatically identify the physical meaning of every parameter. For one normalised first-order lag, G(s) = 1/(τs + 1). Transfer functions multiply when linear components are connected in series. This mathematical representation may describe the output correctly while the physical time constants belonging to individual components remain ambiguous; component identification is a separate question.

Foundations: Lesson 4: Two Tanks in Series

Used in these chapters · 1
Back to the term directory

Transmembrane pressure (TMP)

Related search terms: TMP

TMP describes the pressure difference between retentate and permeate sides of a membrane. A common TFF approximation is TMP = (pFeed + pRetentate)/2 − pPermeate. Measurement locations and pressure references must match.

The average does not describe every local pressure along a module. Rising TMP may indicate increased hydraulic resistance but cannot identify its cause alone. Mechanical and process limits belong to the specific system and application.

Foundations: KrosFlo KR2i Tangential Flow Filtration System

Used in these chapters · 4
Back to the term directory

Trapezoidal rule

Related search terms: trapezoidal integration

The trapezoidal rule approximates an integral by adding trapezoidal areas. Between two measurement points, the average of their function values is multiplied by their time interval. Unequal intervals are permitted but their actual durations must be used separately.

For thermal lethality, temperatures are first converted to lethality rates and those rates are integrated. Exponentiating the average temperature generally gives a different result. Comparison against a finer time grid or an analytically solvable model curve reveals numerical error; it does not repair missing observations or sensor failure.

Used in these chapters · 8
Back to the term directory

Tubular photobioreactor

A tubular photobioreactor circulates a light-dependent culture through transparent tubes. Light enters the suspension through the tube walls, and the tubes may be arranged horizontally, vertically or in loops. A circulation system connects illuminated sections with any separate gas-exchange and temperature-conditioning sections.

Tube diameter sets an important optical path length, while length and liquid velocity affect pressure loss and transit time. Gas composition and temperature can change along a long illuminated section, so circulation alone does not establish uniform cell conditions. Increasing tube diameter enlarges volume faster than illuminated surface area. Scale-up must therefore address light supply and liquid transport together, rather than simply selecting longer or wider tubes.

Back to the term directory

Turbidostat

A turbidostat maintains the measured turbidity of a culture within a selected range. When growth increases the optical signal, the controller increases medium exchange or triggers a defined dilution. Unlike a chemostat, its throughput therefore responds to the culture rather than remaining an independently fixed setting.

Under suitable non-limiting conditions, cells can be studied near their prevailing maximum growth rate. The controller initially stabilises an optical signal, however, rather than necessarily the number of viable cells. Changes in cell size, aggregation, wall growth or gas bubbles affect turbidity. Optical calibration and independent cell measurements determine whether an apparently stable culture remains biologically comparable.

Used in these chapters · 2
Back to the term directory

Turbulent Schmidt number

The turbulent Schmidt number is the ratio of modelled turbulent momentum diffusivity to turbulent mass diffusivity. It belongs to a transport closure and is not the molecular Schmidt number.

Its value affects predicted concentration gradients. Matching mixing time alone does not validate every local trajectory; assess sensitivity of the target quantities. For a specified eddy viscosity, a smaller assumed value gives a larger modelled scalar diffusivity and can weaken predicted gradients. A parameter does not become a material constant merely because software stores it as one number; its origin and the examined sensitivity belong in the model description.

Foundations: Microfluidic Reproduction of Dynamic Bioreactor Environment Based on Computational Lifelines

Back to the term directory

Type A and Type B evaluation

Related search terms: Type A, Type B

Type A evaluates uncertainty statistically from series of observations. Type B uses other available information, such as certificates or justified distribution assumptions.

The distinction does not simply mean random versus systematic error. A calibration-certificate contribution may affect several results together. Combination therefore also depends on relationships between inputs in the measurement model. Additional technical repeats do not reduce a shared contribution from the same reference in the way that independent random scatter is reduced.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 1
Back to the term directory

U

Ultrafiltration (UF)

Related search terms: UF

Ultrafiltration is a pressure-driven membrane separation retaining selected larger dissolved or dispersed components more strongly than liquid and sufficiently small substances. Actual passage depends on membrane, solute and operating conditions.

UF can concentrate a product during protein recovery. Nominal MWCO is only one selection characteristic. Check product loss, final volume, flux profile and composition across the complete run; high initial flux does not fully describe the endpoint.

Foundations: KrosFlo KR2i Tangential Flow Filtration System · Protein preparation handbook

Used in these chapters · 6
Back to the term directory

Ultraviolet radiation

Related search terms: UV radiation, UV light

Ultraviolet radiation is electromagnetic radiation on the shorter-wavelength side of visible light. UVA, UVB and UVC denote spectral ranges. A wavelength label establishes neither the radiant power reaching a target nor its exposure integrated over time.

A microbial inactivation claim therefore needs the spectrum, actual delivered exposure, medium properties and suitable evidence of effectiveness. Shadowing or absorption can leave target regions inadequately reached. Equipment assessment must also consider material compatibility and protection against unintended skin and eye exposure; the label “UV” provides no general guarantee of sterilisation.

Foundations: Ultraviolet (UV) Radiation

Back to the term directory

Unialgal culture

Related search terms: Unialgal

A unialgal culture contains one algal species but may contain additional non-algal organisms. The label therefore makes a narrower statement about algal composition than about overall microbial purity.

It is not synonymous with axenic. Associated bacteria can affect material and gas balances even when a culture appears visually uniform. A claimed axenic state requires appropriate evidence with a specified sampling extent and methodological limits.

Foundations: Tips for physical isolation of bacteria-free, clonal microalgae from marine environmental samples

Used in these chapters · 2
Back to the term directory

Upstream processing

The process segment preparing and carrying out biological production, including starting culture, inoculum, medium preparation and cultivation. The precise organisational interface with harvest or downstream processing is defined for the particular process.

It denotes a process chain rather than one reactor type or guaranteed quality level. Quantity, cost and time comparisons need an explicit list of included operations. Otherwise differently bounded upstream measures can appear comparable when they are not.

Foundations: Our process

Used in these chapters · 3
Back to the term directory

User requirements specification (URS)

Related search terms: user requirements

A user requirements specification states what equipment must achieve for its intended purpose. It covers functional requirements, process limits, materials, interfaces and, where relevant, cleaning, sterilisation and documentation. Good requirements are unambiguous and written so that fulfilment can be verified. A defined working range, for example, is more useful than a vague request for high flexibility.

The URS should distinguish user needs from preferred technical solutions. Fixing a particular construction too early may exclude suitable alternatives without better protecting the actual process objective. For pharmaceutical equipment requiring qualification, the URS provides a reference for later evidence. It is also useful in research laboratories without automatically requiring the same formality. Changes should be assessed traceably for their consequences.

Used in these chapters · 6
Back to the term directory

V

Validation

Related search terms: process validation

Validation provides documented evidence that a defined process reliably achieves its intended outcome under specified conditions. The objective and acceptance criteria must be clear beforehand. Cleaning, sterilisation and a manufacturing step may each raise a separate validation question in bioprocessing. Selected investigations need to cover the relevant influences and challenging conditions adequately.

Validation is more than one successfully completed experiment. A favourable result from an unsuitable study design does not establish repeatability across the intended range. Equally, validated equipment is not automatically validated for every subsequent product. Changes, new knowledge and ongoing results may require reassessment. The formal extent depends on the quality and application context, but technically defensible and traceable evidence remains essential to the conclusion.

Used in these chapters · 14
Back to the term directory

Valve authority

Related search terms: valve authority

Valve authority describes the share of control-valve pressure drop in the pressure difference across the controlled flow branch under consideration. In a common steady design definition, valve drop at design flow with the valve fully open is divided by the sum of valve and remaining branch pressure drops. The selected boundary is part of the value.

A very small share can mean that much of the valve travel has little effect on flow. A larger valve pressure drop also requires additional pumping power. A bioreactor temperature-control loop therefore needs joint assessment of control response, pump curve and pressure losses. One universal target value cannot replace that system design.

Foundations: Control Valve Sizing for Water Systems

Used in these chapters · 1
Back to the term directory

Variable cost

Related search terms: variable costs

Variable cost changes with a stated driver, such as medium volume or filters consumed. It may be approximately proportional, but tiers, minimum quantities and discrete units can alter that relationship.

Specify driver and range in the cost model. Another product kilogram may require different auxiliaries from another culture litre. This prevents a general cost per run being transferred to unsuitable process options.

Foundations: 10.1 Identify Relevant Information for Decision-Making

Used in these chapters · 4
Back to the term directory

Variance

Related search terms: Residual variance

Variance describes a mean squared deviation from the expectation. Its unit is the square of the quantity’s unit. The usual sample variance uses denominator n − 1 for independent identically distributed observations.

Process, sampling and analytical variances refer to different levels. Adding them requires an appropriate model and, for simple sums, absent covariance. The square root of a variance is a standard deviation and has the original unit.

Foundations: Evaluation of measurement data — Guide to the expression of uncertainty in measurement

Used in these chapters · 8
Back to the term directory

Vessel volumes per day

Related search terms: VVD

Vessel volumes per day, commonly abbreviated VVD, expresses daily medium throughput relative to working volume. A flow of 4 L per day through a 2 L culture equals 2 VVD, or a dilution rate of 2 d⁻¹. The working-volume basis and the stream included must be specified.

This measure helps compare perfusion throughput across reactor sizes. It does not directly describe supply per cell: at twice the viable cell density, the same VVD provides half as much medium per cell. Furthermore, 1 VVD in an ideally mixed reactor does not mean that all original liquid has been replaced after one day; mixing leaves a fraction behind.

Back to the term directory

Viability

Viability is the proportion of cells classified as living by a defined test method. For a simple count, viability = 100 × Nᵥ/Nₜ, where Nᵥ is the number classified as viable and Nₜ is the total counted. Results are percentages, and the detection method is an essential part of their meaning.

Dye exclusion commonly assesses membrane integrity, whereas other assays measure metabolic activity or reproductive capability. These properties are not equivalent in every situation. High viability therefore guarantees neither strong productivity nor complete functionality. Sample age, dye exposure and image-analysis settings can alter results. Process decisions should consider viability alongside viable cell concentration and suitable functional information.

Used in these chapters · 17
Back to the term directory

Viable cell density

Related search terms: VCD

Number of cells classified as viable by a defined method per liquid volume, often cells/mL. It differs from total cell concentration and from the dimensionless positive fraction in a viability assay.

A value already reported as viable cell density should not be multiplied by viability again. Measurement principle, counted objects and sample association must be known. Aggregation or changed classification can make results from different methods noninterchangeable.

Foundations: ATCC Animal Cell Culture Guide · Absolute bacterial cell enumeration using flow cytometry

Used in these chapters · 3
Back to the term directory

Viral vector

A system using viral properties to deliver genetic material into cells. It denotes a tool or product class rather than automatically an unchanged natural virus. Properties depend on the particular vector system.

Particle count, genome count and functional delivery are distinct measurements. Manufacturing therefore needs appropriate definitions of product and quality. A generic vector label establishes neither a particular biological function nor suitability for a specific medical application.

Foundations: Vector

Used in these chapters · 3
Back to the term directory

Viscoelasticity

Related search terms: viscoelastic

Viscoelastic behaviour combines viscous dissipation with elastic storage of mechanical energy. Its response consequently depends on loading duration or frequency.

A steady viscosity curve does not fully describe this property. Dynamic assessment needs appropriate loading amplitude and a model within its investigated range. Oscillatory measurements describe elastic storage and viscous loss through separate moduli. Interpretation depends on frequency and loading amplitude. One steady viscosity value does not fully characterise this time-dependent response; the analysis method must also match the linear or nonlinear regime actually investigated in the measurement.

Back to the term directory

Viscosity

Viscosity describes a fluid's resistance to deformation during flow. Dynamic viscosity μ is expressed in Pa·s. Kinematic viscosity ν = μ/ρ additionally accounts for density ρ and has units of m²/s. The quantities are related, but their numerical values and units must not be confused.

Broth behaviour can change as biomass, dissolved macromolecules or aggregates accumulate. This can affect circulation, bubble behaviour and heat transfer simultaneously. A measurement at one imposed flow condition may inadequately describe a non-Newtonian broth. Agitation design should therefore use viscosity information with the relevant temperature, composition and shear-rate range. A low viscosity measured under strong shear may not represent slow-moving regions elsewhere in the vessel.

Used in these chapters · 19
Back to the term directory

Vitamin

Related search terms: vitamins

Vitamins are organic micronutrients with specific biological functions; many are precursors of coenzymes. Whether an organism needs a particular compound supplied by the medium depends on its own biosynthetic capacity and culture conditions. Human vitamin classifications therefore do not constitute a complete nutrient-requirement analysis for a cell line or microorganism.

A medium change must specify the actual compound, salt form, concentration and stability. Equal mass of a vitamin mixture does not guarantee equal provision. In complex materials such as yeast extract, individual vitamin contributions may also be unknown or batch-dependent; requirement and available content are separate questions.

Foundations: Bacteriology Culture Guide · 11965 – DMEM, high glucose: formulation

Used in these chapters · 3
Back to the term directory

Void fraction and porosity

Related search terms: void fraction, porosity

Void fraction is the ratio of specified void volume to total volume. In a packed bed it may refer to spaces between particles; pores within particles require a separate definition.

Residence and flow depend on accessible, wetted space. Total porosity therefore does not automatically represent the effectively flowing liquid volume. The definition must distinguish spaces between particles from pores inside them. Those volumes are not interchangeable for flow and transport. Expansion or compaction of a bed can change its external void fraction while particle mass remains unchanged, so comparisons must state the volume basis and bed condition.

Foundations: Fluidized Bed Reactors, Professional Reference Shelf · Average Linear Velocity

Used in these chapters · 3
Back to the term directory

Volumetric flow rate

Related search terms: Volume flow rate

Volumetric flow rate is the volume transported through a specified surface per unit time, for example L/h or m³/s. For a single-phase flow it is the integral of velocity normal to that surface. Cross-sectional area multiplied by mean velocity gives the same result when the averaging area is defined consistently.

Converting 2 L/min gives 120 L/h, but does not establish substrate delivery without composition information. Gas volume also changes with pressure and temperature. A gas flow reported at reference conditions cannot automatically be treated as the actual volume passing through a reactor headspace. For liquids, evaporation, foam and entrained gas can make an apparent volume flow different from a pure liquid delivery.

Foundations: OpenStax University Physics 1: Fluid dynamics

Used in these chapters · 6
Back to the term directory

Volumetric mass-transfer coefficient kLa

Related search terms: kLa

kLa combines the liquid-side mass-transfer coefficient kL with the specific gas–liquid interfacial area a. If kL is in m/s and a in m²/m³, their product has units of s⁻¹; h⁻¹ is also common. A high value describes rapid concentration equilibration for a given driving force, rather than a fixed amount of oxygen supplied.

The value depends on gas, liquid, geometry and operating conditions. A water-based kLa measurement is consequently not an immutable equipment rating for every culture. Measurement method and the selected analysis interval can also affect the result. Actual oxygen transfer requires combining kLa with the difference between equilibrium and current dissolved concentrations, which may change during the process.

Used in these chapters · 13
Back to the term directory

Volumetric productivity

Related search terms: Volumetric production rate, Space-time yield

Volumetric productivity is formed or recovered quantity per defined volume and time. It may be expressed in g L⁻¹ d⁻¹; the quantity and reference volume used are part of its definition.

Illuminated culture volume alone and total liquid inventory including a degasser yield different values. Variable volume additionally requires a defined time basis. The metric alone describes neither product quality nor energy demand or total plant output.

Foundations: A Simple and Reliable Formula for Assessment of Maximum Volumetric Productivities in Photobioreactors

Used in these chapters · 5
Back to the term directory

vvm

Related search terms: Volumes of gas per volume of liquid per minute

vvm denotes gas volume per liquid volume per minute. It is calculated as QG/VL when gas flow is expressed, for example, in L/min and liquid volume in L. A flow of 2 L/min supplied to 4 L of culture is therefore 0.5 vvm. Its physical dimension is inverse time.

The value is useful for describing aeration, but requires a stated gas temperature and pressure basis and the relevant liquid volume. Equal vvm at different liquid heights does not imply equal superficial gas velocity. It also measures neither oxygen consumption nor oxygen actually transferred. Gas composition, bubble distribution and the transfer driving force remain necessary for assessing whether the culture receives adequate supply.

Used in these chapters · 2
Back to the term directory

W

Warburg effect

Related search terms: Aerobic glycolysis

The Warburg effect describes substantial conversion of glucose into lactate despite adequate oxygen availability. Although the term originates in tumour biology, the corresponding metabolic pattern is also relevant when interpreting proliferating animal cell cultures. Lactate formation helps regenerate NAD⁺ from NADH for glycolysis and can occur alongside mitochondrial respiration.

A rising lactate concentration therefore does not prove oxygen shortage. It also represents the net outcome of formation and any simultaneous uptake. This distinction matters in bioprocesses because cellular state and medium conditions can determine whether cells accumulate lactate or later consume it. The term alone does not explain that dynamic behaviour and does not mean that mitochondria are necessarily non-functional.

Back to the term directory

Washout

Washout is the loss of a growing cell population through withdrawal when net multiplication cannot compensate for cellular outflow. In an ideal chemostat without retention, biomass falls if the effective growth rate remains below the dilution rate. Fewer cells consume less substrate, so residual substrate concentration commonly rises.

The critical dilution rate depends on the organism, medium and operating conditions; it should not simply be equated with a maximum growth rate taken from literature. Inhibition, oxygen limitation or temperature excursions may also trigger washout. Retention reduces outflow but does not eliminate cell death or all losses. Falling density therefore needs interpretation alongside throughput, retention performance and viability.

Used in these chapters · 3
Back to the term directory

Water activity

Related search terms: a_w

Water activity is the thermodynamic activity of water relative to a defined reference state. It is dimensionless and differs from water content or relative liquid quantity.

Solutions with equal water mass fraction can have different water activities because their solutes differ. The distinction may matter for concentrated-feed stability and biological compatibility. Direct conversion from an arbitrary osmolality result requires a suitable thermodynamic model.

Foundations: Water Activity (aw) in Foods

Back to the term directory

Water for injection

Related search terms: WFI, Water for Injection

Water for injection, or WFI, denotes a defined water quality for specified pharmaceutical applications. The applicable pharmacopoeia, intended use and monitored generation, storage and distribution system are relevant. Chemical quality, microbial control and endotoxin burden are distinct assessment aspects.

The term WFI does not mean that every component supplied with it is automatically sterile; water in a distribution system differs from an explicitly sterilised packaged water product. Nor does every bioreactor require WFI. Required water quality and supporting evidence are established for the actual product, process step and applicable pharmaceutical context.

Foundations: EU GMP Annex 1: Manufacture of Sterile Medicinal Products · Sterile Drug Products Produced by Aseptic Processing — Current Good Manufacturing Practice

Used in these chapters · 1
Back to the term directory

Water vapour

Related search terms: water vapor

Water vapour is water in the gaseous phase. It may occur within a gas mixture, as saturated vapour or as superheated steam. Distinguish these states using suitable temperature, pressure and composition data.

In exhaust balances, water vapour changes the wet mole fractions of other gases. Steam treatment also depends on where condensation occurs. Visible white mist contains liquid droplets and is not the same as an invisible pure gas phase.

Foundations: Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam · What is Steam?

Used in these chapters · 8
Back to the term directory

Water–steam saturation state

Related search terms: saturation temperature, saturation pressure

At pure-water liquid–vapour equilibrium, saturation temperature and saturation pressure are linked. Properties differ from subcooled liquid or superheated steam at the same pressure.

Pressure alone does not identify local state. Air in a mixture, different measurement locations or dynamic lag can invalidate a simplified assignment. Thermodynamic pressure requires an absolute basis. In particular, a temperature-pressure pair in the two-phase region does not determine vapour mass fraction; wet and dry saturated steam must be distinguished.

Foundations: Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam

Used in these chapters · 1
Back to the term directory

Weber number

The Weber number We = ρU²L/σ compares inertia with surface-tension effects. Density ρ, velocity U, length L and surface tension σ must match the interface considered.

Bubble size is a different length scale from vessel size. Equal Weber numbers alone establish neither identical bubble distributions nor equal mass transfer. Halving surface tension while keeping fluid, velocity and reference length unchanged doubles We. This does not predict a quantitative bubble size: breakup, coalescence and spatial flow need further description. The dimensionless group compares influences rather than providing a complete population balance or a universal breakup threshold.

Foundations: A simulation modeling framework for fluid motion and transport in a rocking bioreactor

Back to the term directory

Weibull distribution

The Weibull distribution is a family for non-negative times or quantities with positive shape and scale parameters. In the two-parameter lifetime form, shape determines whether the hazard rate decreases, remains constant or increases.

It can describe maintenance and reliability data when observation selection and censoring are accounted for. A fit does not prove a particular failure mechanism. Different failure modes are not pooled without scientific justification merely to obtain a smooth overall fit.

Foundations: Weibull distribution

Back to the term directory

Weighted least squares

Weighted least squares minimises a weighted sum of squared residuals. Weights determine how strongly individual observations influence the fit.

Weights may follow a justified measurement-error model. They should not be chosen retrospectively to hide unwanted discrepancies without scientific justification. Weights are often chosen proportional to inverse error variance when that variance is appropriately known or estimated. Giving preferred observations arbitrary extra weight does not improve evidential strength. If errors are temporally correlated, weighting individual points alone does not fully describe their joint uncertainty structure.

Foundations: How can I detect non-constant variation across the data?

Back to the term directory

Work in progress

Related search terms: work in progress, WIP, waiting inventory

Work in progress is material that has entered the selected process but not reached its defined final state. It may include cultures underway, waiting pools and fractions being processed. Use a quantity unit appropriate to the question.

More work in progress does not automatically mean more completed product. It may require vessels, monitoring and hold allowance. Time balances record entries, exits and initial and final inventories within the same boundary.

Foundations: Basic Concepts in Queueing, lecture8

Used in these chapters · 1
Back to the term directory

Working capital

Related search terms: gross working capital, net working capital

Working capital describes the short-term resources and financing associated with ongoing operations. Gross working capital equals current assets. Net working capital equals current assets minus current liabilities. A reported amount must state which convention it uses.

Inventory and receivables may tie up resources that are unavailable as cash today. A positive net balance therefore does not guarantee immediate liquidity. Balance-sheet amounts refer to a date; project planning additionally needs the actual timing of cash receipts and payments.

Foundations: 19.1 What Is Working Capital?

Used in these chapters · 2
Back to the term directory

Working cell bank (WCB)

Related search terms: Working bank

A working cell bank is prepared by expanding material from a master cell bank, then dispensing and preserving it under defined conditions. It provides the starting material for repeated production cultures. This intermediate stage protects the finite master stock and separates the long-term biological reference from routine manufacturing demand.

Its suitability depends on a documented relationship to the master bank and on demonstrated properties of the working bank itself. Preparing a new working bank is therefore more than replenishing a freezer inventory. Good growth immediately after revival does not establish stable product formation throughout the intended cultivation period. Bank identity, cell age and process conditions must be considered together; similar names do not demonstrate biological equivalence.

Used in these chapters · 2
Back to the term directory

Working volume

Working volume is the liquid volume actually used in a bioreactor at a specified process state. Additions, withdrawals and evaporation can change it over time. A manufacturer's working-volume range instead describes the range assessed for the system's intended function; it does not replace the volume balance for a particular culture.

This quantity appears in the denominator of many performance measures, including power per volume and volumetric metabolic rates. Using an incorrect reference volume therefore changes their meaning directly. The selected fill must also engage impellers and relevant connections appropriately. Initial volume, final volume and, where needed, the volume trajectory communicate more than the nominal vessel-size label when comparing processes.

Used in these chapters · 27
Back to the term directory

Y

Yeast extract

Yeast extract is a complex soluble raw material obtained from disrupted yeast cells, often through autolysis. It can supply peptides, amino acids, vitamins and other small cellular constituents. It is neither living yeast nor a single chemically defined substance.

Two products dosed at the same grams per litre need not have equivalent nutrient compositions. A process change should assess origin, manufacturing method, specification and relevant batch comparisons. Total nitrogen alone, for example, does not describe its distribution between free amino acids, peptides and other nitrogen-containing constituents.

Foundations: Bacteriology Culture Guide · Oxoid Yeast Extract Powder, LP0021B

Used in these chapters · 1
Back to the term directory

Yeasts

Related search terms: Yeast culture

Yeasts are fungi that grow predominantly as individual cells and contain a nucleus and other membrane-bound organelles. Industrial applications include biomass, alcohols and recombinant proteins. Their metabolism combines features of eukaryotic cells with cultivation characteristics attractive for many microbial production processes. Familiar baker’s yeast represents only part of this biological diversity.

Yeast species differ in usable carbon sources, oxygen requirements and the processing of the proteins they produce. Some form ethanol under aerobic conditions when sugar supply is high, whereas others show this behaviour much less strongly. Such carbon diversion has different implications for biomass manufacture and ethanol production. The label yeast alone therefore reveals little about the appropriate supply conditions or achievable product quality.

Used in these chapters · 4
Back to the term directory

Yield coefficient

Related search terms: Biomass yield, Product yield

A yield coefficient relates an amount formed to the resource consumed to form it. Biomass yield on substrate can be written as YX/S = ΔmX/ΔmS,consumed. Here ΔmX is biomass formed and ΔmS,consumed is substrate mass consumed, giving units of g biomass/g substrate. Both quantities must refer to the same interval and system boundary.

The coefficient describes material efficiency rather than speed: high yield can accompany slow production. Maintenance and by-product formation affect the observed value, as does the chosen basis, such as dry mass or carbon moles. With material entering and leaving, subtracting two concentrations is insufficient; the added and withdrawn quantities must also be included.

Used in these chapters · 10
Back to the term directory

Yield stress

Yield stress is the stress threshold separating non-flowing and flowing behaviour in the chosen rheological model. Experimental values also depend on protocol and observation time.

Extrapolating a few measurements towards low shear rate is insufficient evidence. Wall slip, structural change and instrument resolution require assessment. A reported value can depend on procedure, waiting time and previous loading. Very high apparent viscosity at a small shear rate alone does not establish a yield stress. Comparisons therefore state measurement method and interpretation criterion; a fitted parameter is not automatically an independently established material boundary.

Foundations: Rheological Techniques for Yield Stress Analysis, RH025

Used in these chapters · 2
Back to the term directory

Z

z-value

Related search terms: thermal resistance z-value

The z-value is the temperature increase that reduces the D-value of a particular inactivation process by a factor of ten. It therefore describes the sensitivity of inactivation to temperature. In the log-linear model, log₁₀(D₁/D₂) = (T₂ − T₁)/z. The temperature difference and z are expressed in kelvin or degrees Celsius, and D₁ and D₂ correspond to the stated temperatures.

A smaller z-value means stronger temperature dependence. It is not a universal material constant for every microorganism or product. Its determination applies to the investigated range and conditions. When comparing changing temperature histories, the use of a common z-value must therefore be justified; otherwise an apparently precise calculation can produce a misleading equivalence between treatments.

Used in these chapters · 2
Back to the term directory

Zero-order reaction

Related search terms: zero-order kinetics

For a zero-order reaction, the rate considered is independent of concentration within a stated range. Constant consumption r in a closed constant-volume system gives C(t) = C₀ − rt. The rate has units of concentration per time.

This approximation cannot be extended indefinitely to negative concentrations. In the pellet model it represents consumption assumed spatially constant under adequately supplied conditions. A calculated negative core concentration indicates a failed assumption, not a physically possible concentration. A supply-dependent rate or separate active and undersupplied regions may then be needed. The relevant range must be established for the particular reaction and transport situation.

Foundations: Integrated Rate Laws

Back to the term directory

Zwitterion

A zwitterion carries positive and negative formal charges within the same molecular species while having zero net charge. Many amino acids can adopt this form in a suitable pH range.

Net neutrality does not mean absence of interactions with water or ions. Media and buffer calculations need the pH-dependent distribution of forms. The term describes charge structure, not a general certificate of biological buffer compatibility.

Foundations: 26.2 Amino Acids and the Henderson–Hasselbalch Equation: Isoelectric Points

Back to the term directory