What needs to be done?
| Task | First question | Next step |
|---|---|---|
| Prepare a run | Have culture condition, medium, measurements and aseptic transfers been planned together? | Before the run |
| Understand a deviation | Is the signal reliable, and when did the change begin? | Decision tree |
| Improve a process | Which hypothesis should the comparison distinguish? | Plan experiments |
| Evaluate an outcome | Do amounts, timing and uncertainties agree? | Evaluate data |
Before the run: consider the complete process path
Preparation starts with a defined culture and a suitable transfer condition. A sufficient liquid volume alone does not describe a suitable inoculum. The seed-train section connects quantity planning with biological condition. Culture media covers substrate, nitrogen and salt provision; aseptic processing addresses barriers at additions, gas paths and sampling points.
Useful preparation documents the intended condition and its evidence. Which reservoir is connected? Which measurement was checked, under what conditions? Which pump calibration applies to the tubing actually used? Which connection will be opened or switched during the run? Component requirements helps turn these questions into testable functions.
Outcome of this route: a traceable starting condition covering medium identity, culture transfer, configuration and measurement status. A general reading route does not replace a system-specific release for operation.
During the run: connect signals with material flows
A controlled value can appear stable while the equipment uses progressively more control effort. Read process variables together with manipulated variables: for dissolved oxygen, this may include agitation, gas flows and gas composition; for pH, the actual acid and base additions. The DO cascade explains how control effort is distributed. Representative sampling explains when an external analysis describes the same process condition.
The volume balance and conversion of feed mass to volume connect pump programmes with actual amounts. Recorded setpoints do not prove that liquid reached the reactor. Units, timestamps, empty reservoirs and reservoir changes therefore remain part of the record.
When a deviation occurs: test hypotheses in sequence
| Symptom | Technical section |
|---|---|
| DO falls or the cascade reaches a limit | Separate measurement, demand and transfer |
| pH and the laboratory result disagree | Measurement conditions and sample state |
| Feed does not match reservoir weight | Delivery mass balance |
| Foam, exhaust and temperature change together | Coupled causes |
| Contamination is suspected | Distinguish culture, sample and analytical errors |
A single observation does not immediately establish a cause. A shared event timeline helps distinguish responses from triggers. Establish the safe state and responsible people before investigating causes through interventions.
Improvement: connect each change with a decision
A higher titre may come with a longer run, more medium or poorer downstream recovery. Start with the desired outcome and a suitable comparison metric. The experimental question and distinction between replication, randomisation and blocking make comparisons more defensible.
An agitation comparison, for example, must consider the biological starting condition, fill volume, gas conditions and sampling plan. Scale-up and scale-down explains which criteria can actually be held constant. Changing several factors at once can be useful, but requires a planned experimental space rather than assigning one cause afterwards.
After the run: recover usable knowledge, not just curves
Evaluation connects actual material flows, observed culture development and the desired product. Usable harvest and calendar productivity distinguishes reactor output from usable performance; downstream yields shows how losses compound across stages.
The final record distinguishes measurements, calculations and assumptions. Unresolved hypotheses remain unresolved. A successful correction needs an appropriate effectiveness check. For students, the reporting module offers an introduction; for recurring operation, maintenance planning and change assessment connect lessons with the next use.
Detailed learning paths and complete worked cases
Work through one question along its three connected chapters. Each path includes assumptions, reproducible cases and useful further sources. Use the chapter terminology lists to resolve unfamiliar prerequisites.
| Question | Chapter path | Outcome |
|---|---|---|
| Analyse feed and carbon data | Fed-batch data analysis → Diagnosing feed deviations → Carbon and redox balances | Reconstruct a run as material balances and narrow down feed faults. |
| Determine growth and substrate demand | Estimating growth rates → Substrate uptake and yields → Modelling maintenance metabolism | Estimate kinetic quantities from suitable intervals and explain their limitations. |
| Interpret oxygen signals | kLa from data → Sensor response → Gas switching and off-gas | Distinguish liquid dynamics, sensor response and gas reference basis. |
| Understand medium chemistry in operation | Medium chemistry and moles → Buffers, CO₂ and pH → Osmolality and dosing | Account consistently for formulation, buffer state and osmotic reference quantities. |
| Assess thermal exposure | Thermal exposure → Steam quality and condensate → Temperature mapping and evidence | Integrate temperature histories and identify the limits of sterilisation evidence. |
| Trace culture history | Strain and cell banks → Culture history and cell age → Inoculum quality and transfer | Connect cell banks, transfers and inoculum state. |
| Close a perfusion balance | Cell retention → Perfusion balances → Perfusion productivity | Calculate medium exchange, cell retention and actual product harvest separately. |
| Assess viscous and filamentous cultures | Non-Newtonian broths → Filamentous morphology → Measuring mixing power | Relate flow curves, morphology and mechanical power to the same process question. |
| Describe spatial and temporal differences | Tracer and residence time → Compartment models → Cell lifelines | Interpret tracer data, compartment models and cell paths as different information. |
| Account for light and photoproductivity | Light measurement → Light attenuation → Photobioreactor productivity | Specify the measured quantity, light path and area/volume basis before comparing. |
| Connect nitrogen conversion and aeration | Nitrogen balances → Alkalinity → Oxygen demand | Reconcile nitrogen, alkalinity and oxygen balances. |
Terms in this chapter
34 terms explained in the glossary
- Alkalinity
- Asepsis
- Bioreactor
- Blocking
- Calibration
- Cell retention
- Condensate
- Contamination
- Dissolved oxygen measurement
- Downstream processing (DSP)
- Equipment maintenance
- Exposure
- Fed-batch culture
- Foam
- Harvest
- In-vitro cell age
- Independent replication
- Inoculum
- Maintenance metabolism
- Material balance
- Osmolality
- Perfusion
- pH measurement
- Photobioreactor
- Product recovery
- Product titre
- Randomisation
- Scale-down
- Scale-up
- Steam quality
- Sterilisation
- Substrate
- Temperature mapping
- Volumetric mass-transfer coefficient kLa