What needs to be done?

Choose a practical route
TaskFirst questionNext step
Prepare a runHave culture condition, medium, measurements and aseptic transfers been planned together?Before the run
Understand a deviationIs the signal reliable, and when did the change begin?Decision tree
Improve a processWhich hypothesis should the comparison distinguish?Plan experiments
Evaluate an outcomeDo amounts, timing and uncertainties agree?Evaluate data

Before the run: consider the complete process path

Preparation starts with a defined culture and a suitable transfer condition. A sufficient liquid volume alone does not describe a suitable inoculum. The seed-train section connects quantity planning with biological condition. Culture media covers substrate, nitrogen and salt provision; aseptic processing addresses barriers at additions, gas paths and sampling points.

Useful preparation documents the intended condition and its evidence. Which reservoir is connected? Which measurement was checked, under what conditions? Which pump calibration applies to the tubing actually used? Which connection will be opened or switched during the run? Component requirements helps turn these questions into testable functions.

Outcome of this route: a traceable starting condition covering medium identity, culture transfer, configuration and measurement status. A general reading route does not replace a system-specific release for operation.

Explore seed-train and inoculum planning.

During the run: connect signals with material flows

A controlled value can appear stable while the equipment uses progressively more control effort. Read process variables together with manipulated variables: for dissolved oxygen, this may include agitation, gas flows and gas composition; for pH, the actual acid and base additions. The DO cascade explains how control effort is distributed. Representative sampling explains when an external analysis describes the same process condition.

The volume balance and conversion of feed mass to volume connect pump programmes with actual amounts. Recorded setpoints do not prove that liquid reached the reactor. Units, timestamps, empty reservoirs and reservoir changes therefore remain part of the record.

When a deviation occurs: test hypotheses in sequence

Symptom and useful starting point
SymptomTechnical section
DO falls or the cascade reaches a limitSeparate measurement, demand and transfer
pH and the laboratory result disagreeMeasurement conditions and sample state
Feed does not match reservoir weightDelivery mass balance
Foam, exhaust and temperature change togetherCoupled causes
Contamination is suspectedDistinguish culture, sample and analytical errors

A single observation does not immediately establish a cause. A shared event timeline helps distinguish responses from triggers. Establish the safe state and responsible people before investigating causes through interventions.

Improvement: connect each change with a decision

A higher titre may come with a longer run, more medium or poorer downstream recovery. Start with the desired outcome and a suitable comparison metric. The experimental question and distinction between replication, randomisation and blocking make comparisons more defensible.

An agitation comparison, for example, must consider the biological starting condition, fill volume, gas conditions and sampling plan. Scale-up and scale-down explains which criteria can actually be held constant. Changing several factors at once can be useful, but requires a planned experimental space rather than assigning one cause afterwards.

After the run: recover usable knowledge, not just curves

Evaluation connects actual material flows, observed culture development and the desired product. Usable harvest and calendar productivity distinguishes reactor output from usable performance; downstream yields shows how losses compound across stages.

The final record distinguishes measurements, calculations and assumptions. Unresolved hypotheses remain unresolved. A successful correction needs an appropriate effectiveness check. For students, the reporting module offers an introduction; for recurring operation, maintenance planning and change assessment connect lessons with the next use.

Detailed learning paths and complete worked cases

Work through one question along its three connected chapters. Each path includes assumptions, reproducible cases and useful further sources. Use the chapter terminology lists to resolve unfamiliar prerequisites.

Detailed learning paths with an assessable outcome
QuestionChapter pathOutcome
Analyse feed and carbon dataFed-batch data analysis → Diagnosing feed deviations → Carbon and redox balancesReconstruct a run as material balances and narrow down feed faults.
Determine growth and substrate demandEstimating growth rates → Substrate uptake and yields → Modelling maintenance metabolismEstimate kinetic quantities from suitable intervals and explain their limitations.
Interpret oxygen signalskLa from data → Sensor response → Gas switching and off-gasDistinguish liquid dynamics, sensor response and gas reference basis.
Understand medium chemistry in operationMedium chemistry and moles → Buffers, CO₂ and pH → Osmolality and dosingAccount consistently for formulation, buffer state and osmotic reference quantities.
Assess thermal exposureThermal exposure → Steam quality and condensate → Temperature mapping and evidenceIntegrate temperature histories and identify the limits of sterilisation evidence.
Trace culture historyStrain and cell banks → Culture history and cell age → Inoculum quality and transferConnect cell banks, transfers and inoculum state.
Close a perfusion balanceCell retention → Perfusion balances → Perfusion productivityCalculate medium exchange, cell retention and actual product harvest separately.
Assess viscous and filamentous culturesNon-Newtonian broths → Filamentous morphology → Measuring mixing powerRelate flow curves, morphology and mechanical power to the same process question.
Describe spatial and temporal differencesTracer and residence time → Compartment models → Cell lifelinesInterpret tracer data, compartment models and cell paths as different information.
Account for light and photoproductivityLight measurement → Light attenuation → Photobioreactor productivitySpecify the measured quantity, light path and area/volume basis before comparing.
Connect nitrogen conversion and aerationNitrogen balances → Alkalinity → Oxygen demandReconcile nitrogen, alkalinity and oxygen balances.

Terms in this chapter