Which calculation answers your question?

Choose the question, then check units and assumptions in the linked worked case. These short formulas apply only under the stated conditions. Symbols such as n have different meanings in different cases; the local definition is part of the calculation.

Quick access to twelve worked cases
QuestionShort formulaExample result unit
Volume balanceV = V₀ + ΣVin − ΣVoutL
Mass to volumeV = m / ρL
Amount of substancen = m / Mmol
Exponential feedF(t) = F₀ exp(μt)L/h
Oxygen transferOTR = kLa (c* − c)concentration/time
Mass transfer coefficientkLa = ln[(c*−c₁)/(c*−c₂)] / Δth⁻¹
Ideal gas flowṅ = p Q / (R T)mol/s
Impeller tip speedu = π d nm/s
Heat dutyQ̇ = ṁ cp ΔTkW
Usable product massmP = cP V ηg / kg
Dilution rateD = F / Vh⁻¹
Cell-specific medium demandCSPR = F / (Xv V)volume/(cell·time)

1. Working volume after additions, sampling and evaporation

Question: Which volume belongs with a concentration measured at the end of a run? Required inputs are starting volume V₀, every liquid addition, withdrawn samples, harvest and a justified evaporation estimate. The nominal volume printed on the vessel is not a balance quantity. For markedly different temperatures or concentrated mixtures, also examine whether treating liquid volumes as additive is sufficiently accurate.

VEnd = V₀ + ΣVAdded − ΣVWithdrawn − VEvaporated
Volume unit = L; concentration c = m/V in g L⁻¹

Hypothetical example: A run begins with 2.00 L. During the interval, 0.30 L feed and 0.04 L other dosing liquids enter. Samples remove 0.06 L in total and estimated net evaporation is 0.02 L. Final volume is therefore 2.26 L. A measured product concentration of 4.0 g L⁻¹ corresponds to 9.04 g product inside the reactor at that instant.

Using the starting volume instead would give only 8.00 g. This understates current inventory by 1.04 g, or 11.5% of the correct inventory. The result is not yet total product formation: product removed in earlier samples and possible degradation are absent. A formation balance must include each sample volume multiplied by its concentration at the time of withdrawal.

Typical error: An increased concentration is attributed entirely to product formation. Water evaporation raises the concentration of a retained substance even without additional formation. Conversely, a product-free addition dilutes the existing inventory. Write the general balance for m = cV rather than concentration alone.

If evaporation is uncertain, calculate a plausible interval instead of reporting a misleadingly exact value. Volume uncertainty of ±0.02 L contributes ±0.08 g inventory uncertainty when concentration is held at 4.0 g L⁻¹. Concentration uncertainty contributes separately. Operating modes explains variable-volume balances; sampling explains the required time reference.

2. Convert feed weighing into volume and substrate mass

Question: How much substrate was withdrawn from a feed supply? A balance measures mass. Liquid volume requires feed density ρF, followed by the appropriate concentration SF to determine contained substrate mass. Establish whether the recipe states grams per litre of final solution or a mass fraction. These quantities enter the calculation differently.

VF = ΔmSupply/ρF
mSubstrate = SF · VF
F = VF/Δt

Hypothetical example: The supply loses 33.0 g in 30 minutes. At the temperature considered, feed density is assumed to be 1.10 g mL⁻¹ and concentration is 100 g substrate per litre of final solution. Withdrawal therefore represents 30.0 mL solution and 3.00 g substrate. Mean liquid flow is 1.00 mL min⁻¹, equivalent to 0.0600 L h⁻¹; substrate flow is 6.00 g h⁻¹.

Assuming without verification that 1 g equals 1 mL would produce 33 mL and 3.3 g. Both results would exceed the correct value by 10%. However, if the recipe instead specified a mass fraction of 10%, those same 33 g of solution would indeed contain 3.3 g substrate. The difference comes from the definition rather than a different balance reading.

Typical error: Supply loss is equated with delivery into the reactor. A sample from the reservoir, leakage or another connection route can also remove mass. Weighing initially checks the boundary around the supply. Confirming the delivery path is necessary before attributing all withdrawal to the reactor. Tubes resting on the balance, temperature change and drift also belong in measurement assessment.

For pump comparisons, match the time interval and operating state. A mean discrepancy can conceal brief interruptions that matter biologically. Where density or concentration changes, calculate separate intervals. Troubleshooting turns the quantity balance into a targeted investigation; media and feeding covers recipe definitions and preparation in greater depth.

3. Connect grams, millimoles and specific rates correctly

Question: How can an analytical amount-of-substance result be used in a balance expressed in grams? For a defined chemical substance, n = m/M, where n is amount in mol, m is mass in g and M is molar mass in g mol⁻¹. Substance identity includes water content, salt form and purity. Biomass dry mass, by contrast, has no universal molar mass equivalent to that of a pure chemical.

1 mmol = 10⁻³ mol
1 L = 10⁻³ m³
1 mmol L⁻¹ = 1 mol m⁻³
1 g L⁻¹ = 1 kg m⁻³

Hypothetical example: A glucose solution contains 0.900 g L⁻¹. For this teaching calculation, M is explicitly rounded to 180 g mol⁻¹. Concentration is consequently 0.00500 mol L⁻¹, or 5.00 mmol L⁻¹. A 100 L quantity contains 0.500 mol rather than 500 mol. Its corresponding mass remains 90.0 g. Multiplying n by M provides a quick reverse check for a missing factor of one thousand.

The next calculation uses a rounded oxygen molar mass of 32 g mol⁻¹. Thus 32 mg O₂ equals 1 mmol O₂ within that rounding. Consumption of 640 mg L⁻¹ h⁻¹ becomes 20 mmol L⁻¹ h⁻¹. Dividing by X = 10 g dry biomass per litre gives a specific rate of 2 mmol g⁻¹ h⁻¹.

Typical error: A volumetric rate is multiplied by biomass again even though it already includes qX. Use q for a biomass-specific rate and r for a culture-volume-specific rate. Total hourly consumption is rV. Changing culture volume changes that total flow even if r remains unchanged.

Likewise, h⁻¹ and s⁻¹ are not interchangeable: 120 h⁻¹ equals 0.0333 s⁻¹. The BIPM introduction to SI explains units and prefixes. Actual calculations require molar mass and purity from the appropriate substance information; the rounded values here serve only to demonstrate the method.

4. Calculate an idealised exponential feed

Question: Which substrate feed follows from an assumed constant specific growth rate? Inputs are initial biomass mass MX₀, growth rate μ, biomass yield YX/S and substrate concentration SF in the feed solution. The model assumes substrate-limited growth, negligible residual substrate, constant yield and no maintenance, product-associated demand or biomass withdrawal. It describes biomass mass rather than an automatically exponential concentration.

MX(t) = MX₀ exp(μt)
F(t) = μMX(t)/(YX/S · SF)
V(t) = V₀ + [MX(t) − MX₀]/(YX/S · SF)

Hypothetical example: V₀ = 1.50 L and X₀ = 8.0 g L⁻¹ give MX₀ = 12.0 g. Assume μ = 0.12 h⁻¹, YX/S = 0.50 g g⁻¹ and SF = 400 g L⁻¹. Initial feed is 0.00720 L h⁻¹, or 7.20 mL h⁻¹. After four hours, exp(0.48) = 1.6161: biomass mass is 19.393 g and feed is 11.636 mL h⁻¹.

Accumulated feed volume is then 0.03696 L, increasing working volume to 1.53696 L. Biomass concentration is therefore 12.618 g L⁻¹. Dividing the biomass mass by starting volume would overstate concentration. The exponent μt must be dimensionless, so a rate expressed in h⁻¹ requires time in hours.

Typical error: The calculated feed is treated as evidence that the culture actually achieves the assumed growth rate. Oxygen, heat removal, nitrogen or another nutrient limit can alter the trajectory. Substrate may then accumulate even though the mathematical feeding curve has been programmed correctly.

Check actual withdrawal, residual substrate, biomass and suitable respiratory indicators. Significant maintenance requires additional substrate demand; sampling loss or other liquid flows change the balances. Fed-batch and operating modes explains these extensions. This calculation supplies an assessable starting hypothesis for development rather than a universal dosing recipe. Its usefulness depends on recording departures from the assumptions and revising the model when observations require it.

5. Compare OTR, OUR and required kLa

Question: Is oxygen transfer at the liquid condition considered sufficient for consumption? C* denotes equilibrium concentration appropriate to the actual gas phase, while CL is dissolved concentration in the medium. kLa has units h⁻¹. Volumetric oxygen consumption is represented here by OUR = qO₂X; q and X must use the same biomass basis.

OTR = kLa(C* − CL)
OUR = qO₂X
kLa,required = OUR/(C* − CL)

Hypothetical example: C* = 8.0 mg L⁻¹, CL = 2.4 mg L⁻¹ and kLa = 120 h⁻¹ give OTR = 672 mg L⁻¹ h⁻¹. Using 32 mg mmol⁻¹, this is 21.0 mmol L⁻¹ h⁻¹. For qO₂ = 0.80 mmol g⁻¹ h⁻¹ and X = 20 g L⁻¹, OUR is 16.0 mmol L⁻¹ h⁻¹, equivalent to 512 mg L⁻¹ h⁻¹.

The difference at this condition is 5.0 mmol L⁻¹ h⁻¹. Relative to demand it is 31.25%; relative to transfer it is 23.81%. A percentage without its reference quantity would be ambiguous. Required kLa is 512/5.6 = 91.43 h⁻¹. This is not a generally recommended minimum; it follows from the assumed concentrations and consumption.

Typical error: OTR and OUR are always equated despite changing DO. The simple constant-volume model gives dCL/dt = OTR − OUR. If the stated values are simultaneously valid, CL initially rises; they do not imply a stationary concentration. Control may subsequently change gas composition or agitation.

C* is neither a permanently fixed water solubility nor automatically the concentration represented by a displayed 100%. Temperature, pressure, gas composition and medium must match. A single sensor can also miss local gradients. Mixing and oxygen transfer explains measurement and design limitations. A defensible capacity comparison examines plausible adverse combinations rather than combining favourable individual values taken from different run phases.

6. Determine kLa from an idealised re-aeration trace

Question: Which transfer coefficient explains approach towards a constant equilibrium concentration? Without oxygen consumption and with well-mixed liquid, the concentration deficit decreases exponentially. Use the ratio of deficits at two times. The logarithm consequently contains a dimensionless quantity rather than an isolated concentration carrying a unit.

kLa = ln[(C* − C₁)/(C* − C₂)]/(t₂ − t₁)

Hypothetical example: Let C* be 0.250 mmol L⁻¹. Liquid concentration rises from C₁ = 0.050 to C₂ = 0.150 mmol L⁻¹ over 60 s. The deficit falls from 0.200 to 0.100 mmol L⁻¹. Therefore ln(2)/60 gives 0.01155 s⁻¹, or 41.59 h⁻¹. The corresponding transfer time constant, 1/kLa, is 86.56 s.

This calculation assumes constant volume, temperature, gas composition and flow conditions. C* must be known and sufficiently constant during the interval. Delayed gas switching or an incompletely exchanged headspace can violate that assumption. Biological consumption introduces an OUR term into the balance; the unchanged two-point method would then be unjustified.

Typical error: The displayed probe trace is treated as the liquid trajectory without checking response time. An assumed probe time constant of 20 s is not obviously negligible beside 86.56 s. Where needed, fit liquid dynamics and probe response together. Merely shifting the time axis does not generally correct the shape of a sluggish signal.

Practical assessment uses several suitable observations, repeats and model residuals. Close to saturation, the deficit becomes small and measurement error has a large relative effect. The original study by Pappenreiter and colleagues describes a specific dynamic characterisation and its probe limitations. Its equipment values are not universal conditions. Mass transfer develops the coupled measurement model and explains why results from one test liquid cannot automatically represent an actual culture broth.

7. Convert gas volume to molar flow and operating conditions

Question: What does ten litres of gas per minute mean in a balance? The statement requires temperature, absolute pressure and whether it is dry or wet. For an ideal gas, pQ/(RT) gives molar flow. Q must be volumetric flow at exactly the condition described by p and T.

ṅ = pQ/(RT)
QOperating = QReference · TOperating/TReference · pReference/pOperating
R ≈ 8.31446 J mol⁻¹ K⁻¹

Hypothetical example: Dry flow is 10.0 L min⁻¹ at explicitly selected reference conditions of 0°C and 1.01325 bar absolute. These inputs become 0.600 m³ h⁻¹, 273.15 K and 101,325 Pa. Molar flow is 26.769 mol h⁻¹. At 35°C and 1.20 bar absolute, that same dry molar flow occupies 9.526 L min⁻¹.

Operating volume is smaller despite warming because the pressure effect dominates. Both changes must be included together. A display in reference litres should not be inserted into the first equation as though it measured actual volume at 35°C. That would apply the state correction incorrectly or twice.

Typical error: Gauge pressure replaces absolute pressure, or Celsius replaces kelvin. Another error combines dry gas analysis directly with wet total volume flow. If the wet stream has a known water mole fraction yW, its dry molar flow is ṅdry = ṅwet(1 − yW). Fractions and flows must describe matching conditions and times.

For exhaust balances, inlet and outlet flows are not generally equal. Oxygen consumption, CO₂ formation and water removal alter total flow. A suitable inert-gas balance can determine dry outlet flow when its assumptions hold. Gas balances explains the full calculation. The NIST constants table lists R and ideal molar volumes with reference conditions; an instrument specification must explicitly state its own reference. At conditions where ideal-gas behaviour is insufficient, an appropriate compressibility treatment is also required.

8. Compare geometric enlargement and agitation criteria

Question: Which agitation speed follows from equal power input per volume? For geometrically similar stirred vessels, length ratio is λ = (V₂/V₁)¹ᐟ³. At equal density and constant power number, P = NPρN³d⁵. N is rotational frequency in s⁻¹ and d is impeller diameter. The model assumes comparable turbulent flow; aeration can alter power.

P/V ∝ N³d²
At equal P/V: N₂/N₁ = λ⁻²ᐟ³
Tip speed u = πNd; u₂/u₁ = λ¹ᐟ³

Hypothetical example: Working volume rises from 10 to 1,000 L, a factor of 100. λ is 4.6416. Starting agitation of 600 min⁻¹ becomes 215.63 min⁻¹ at equal P/V. Tip speed simultaneously increases by a factor of 1.6681. Equal specific power therefore does not imply equal impeller tip speed.

Holding tip speed instead gives N₂/N₁ = 1/λ, or a target of 129.27 min⁻¹. P/V then falls to 1/λ = 0.2154 of its initial value. The two criteria cannot both be maintained through a single adjustable speed. At equal P/V, total shaft power also grows in proportion to volume, by a factor of 100.

Typical error: Volume ratio is used as diameter ratio, generating extreme incorrect powers. First inspect actual internal dimensions, impeller spacing and liquid height. A vessel with a different height ratio is not geometrically similar simply because it belongs to the same supplier family.

An assumed relation tmixN = constant would predict a 2.783-fold longer mixing time under the first criterion. This is a conditional scaling estimate rather than an observed result. Gas distribution, rheology and internals can invalidate it. Scale-up assesses criteria alongside local gradients and actual acceptance data. The purpose of this calculation is to compare consequences transparently and identify which missing measurements matter before choosing a transfer strategy.

9. Distinguish cooling duty, water flow and energy

Question: Which cooling-water flow can absorb a known heat load? Required inputs are heat-flow rate Q̇, specific heat capacity cp and inlet/outlet temperatures of the actual cooling stream under consideration. A water-side balance applies at steady conditions without material side losses. It initially describes heat in the coolant rather than automatically demonstrating transfer through the vessel wall.

Q̇ = ṁcp(Tout − Tin)
ṁ = Q̇/[cp(Tout − Tin)]
E = Q̇Δt at constant duty

Hypothetical example: Required removal is 12.0 kW. Water enters at 14°C and leaves at 18°C; assume cp = 4.18 kJ kg⁻¹ K⁻¹. Since 1 kW = 1 kJ s⁻¹, ṁ = 12/(4.18 · 4) = 0.7177 kg s⁻¹. With assumed density of 1 kg L⁻¹, this is 43.06 L min⁻¹.

If the load remains constant for four hours, removed heat is 48.0 kWh. This does not automatically mean that the chiller consumes 48.0 kWh of electricity. That requires its actual coefficient of performance and the pumps and auxiliaries included within the boundary. A temporary load is integrated over its trajectory rather than multiplied by the entire run duration.

Typical error: Cooling-water flow and return temperature are fixed independently even though transferred heat has already been specified differently. At 43.06 L min⁻¹ and only a 2 K temperature rise, transported heat is approximately 6 kW. Simultaneous reported values of 12 kW would indicate inconsistent measurement, boundary or steady-state assumptions.

Wall transfer additionally requires U, area and the appropriate mean temperature difference. Warmer supply can limit duty even when the pump moves sufficient liquid. Transiently, medium and steel can also store heat. Facility utilities calculates these conditions together. Diagnosis therefore records culture temperature, supply, return, actual flow and load phase on a common time axis. A rated chiller power alone cannot resolve which of these quantities limits the installation.

10. Calculate usable harvest and calendar productivity

Question: How much product remains after defined losses, and what equipment output follows? Inputs are actually harvested volume VH, product concentration cH and individual downstream recoveries η. Every recovery must refer to the same product definition. Protein mass, biological activity and releasable mass are different targets.

mUsable = VHcH · η₁η₂…
rCalendar = mUsable/tOccupancy
rVolume = mUsable/(VReference · tOccupancy)

Hypothetical example: A 50.0 L harvest at 3.0 g L⁻¹ contains 150 g product. Two steps retain 90% and then 80% of the respective incoming quantity. Usable output is 108 g; overall recovery is 72%, not 70%. If the reactor spends 36 hours cultivating and another twelve hours in preparation and turnaround, its occupancy is 48 hours.

Calendar output is 108/48 = 2.25 g h⁻¹. Using an explicitly selected reference volume of 50 L gives 0.0450 g L⁻¹ h⁻¹. A metric based only on culture time would instead be 0.0600 g L⁻¹ h⁻¹. Both calculations are mathematically correct but answer different questions. The denominator therefore belongs in the label.

Typical error: The highest concentration from one run is combined with the largest possible volume and shortest culture time from other runs. This creates a process that was never actually observed. Unusable residual liquid in the vessel also does not automatically belong in the harvested quantity.

Thirty completely available days contain 720 hours. With no further constraints, they accommodate fifteen complete 48-hour cycles, producing 1.620 kg usable product. Failures, shared downstream equipment, analysis time and material availability can reduce this output. Waiting for release outside the reactor need not automatically extend reactor occupancy. Economics and downstream processing connect these separate capacity limits. Retain them separately in the calculation so that a proposed improvement is assigned to the bottleneck it actually affects.

11. Distinguish dilution rate, residence time and chemostat limits

Question: Which liquid exchange rate results from continuous flow? For constant, well-mixed volume with equal inlet and outlet, D = F/V. D has units h⁻¹; mean hydraulic residence time is τ = V/F. These relations do not yet establish whether biomass can grow or be retained in the system.

D = F/V; τ = 1/D
Ideal chemostat without cell retention: μ = D
Monod model: S* = DKS/(μmax − D)

Hypothetical example: F = 0.180 L h⁻¹ and V = 2.00 L give D = 0.0900 h⁻¹ and τ = 11.111 h. One residence time does not mean complete liquid replacement in an ideally mixed vessel: an ideal tracer that is not replenished retains exp(−1) = 36.8% of its starting inventory after τ. Removal is exponential rather than a sharp displacement front.

For a further idealised model, assume μmax = 0.300 h⁻¹, KS = 0.050 g L⁻¹ and feed substrate Sin = 5.00 g L⁻¹. This model neglects maintenance, death and additional substrate losses. The non-washout stationary solution at D = 0.0900 h⁻¹ gives S* = 0.02143 g L⁻¹. At YX/S = 0.50 g g⁻¹, X* = YX/S(Sin − S*) = 2.489 g L⁻¹.

Typical error: Every dilution rate below μmax is regarded as protection against washout. With finite inlet concentration, the ideal Monod-model boundary is μ(Sin) = 0.2970 h⁻¹. Actual cultures may have additional nutrient limits, death or oxygen shortage. The formal positive solution also requires S* below Sin.

Application requires actual volume, all liquid flows, residual substrate and biomass. During a transition, dX/dt need not be zero, so D alone does not measure μ. Continuous operating modes explains stability, startup and the distinction from cell retention. The calculated stationary state is a model prediction to test, not a substitute for observing whether the culture approaches a stable condition under its actual constraints.

12. Connect perfusion flow, CSPR, bleed and product harvest

Question: How do medium exchange and cell removal interact under retention? Keep liquid volume V, viable-cell concentration XV, total medium inlet FM and bleed FB separate. Here CSPR denotes medium flow per viable cell per day. The example assumes complete cell retention in the separation route while dissolved product passes freely.

CSPR = FM/(XV · V)
Stationary complete cell retention: FB/V = μ − kd
FH = FM − FB at constant volume

Hypothetical example: A 10 L culture contains 20 million viable cells per mL, totalling 2 · 10¹¹ cells. With 20 L medium per day, exchange is 2 d⁻¹ and CSPR is 100 pL cell⁻¹ d⁻¹. The conversion uses 1 L = 10¹² pL; litres in the numerator must correspond to the total cell count.

Assume μ = 0.25 d⁻¹ and kd = 0.02 d⁻¹. Maintaining constant viable-cell concentration requires FB = 2.30 L d⁻¹ in this simplified model. Cell-depleted harvest flow is then 17.70 L d⁻¹. Overall liquid residence time V/FM is 0.50 d. The time derived from cell removal, V/FB, is instead 4.35 d; it does not describe the age of every individual cell.

If harvest contains 0.200 g L⁻¹ product, it recovers 3.54 g d⁻¹. Another 0.46 g d⁻¹ leaves through bleed if that stream also contains dissolved product at 0.200 g L⁻¹. If discarded, this product belongs to loss rather than usable harvest. The distinction matters even when the culture concentration appears stable throughout the day.

Typical error: Total medium inlet is used as harvest flow despite simultaneous bleed. Partial cell or product retention also changes the equations. Measured passage, death, sampling and accumulation must then be included explicitly. Perfusion and cell culture explain the biological and technical data needed to turn this balance into a defensible process decision. The assumed numbers demonstrate relationships and do not prescribe a cell density, exchange rate or growth target.

Frequently asked questions

Can I use the example numbers directly as setpoints?

No. The examples are explicitly hypothetical. Transfer the calculation method using appropriate inputs, checked measurements and the validity limits of the particular model.

What is the quickest way to check a calculation?

Write every input with its unit, check the balance boundary and calculate backwards into a known quantity. Then ask whether the assumptions match the actual run phase.

Why can two correctly calculated productivities differ?

Reference volume, product definition or time basis often differs. Culture time, reactor occupancy and available calendar time answer different capacity questions and must be stated with the metric.

Terms in this chapter

56 terms explained in the glossary